background image

Instruction Manual

FCC Compliance Statement

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B  digital 

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation. This equipment generates, 

uses and can radiate radio frequency energy and, if not installed and used in accordance with 

the  instructions,  may  cause  harmful  interference  to  radio  communications.  However,  there 

is no guarantee that interference will not occur in a particular installation. If this equipment 

does cause harmful interference to radio or television reception, which can be determined by 

turning the equipment off and on, the user is encouraged to try to correct the interference by 

one or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver 

is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

Use of Trademarks, Registered Trademarks, and other Protected Names and 

Symbols

This  manual  may  make  reference  to  trademarks,  registered  trademarks,  and  other 

protected  names  and/or  symbols  of  third-party  companies  not  related  in  any  way  to  

StarTech.com.  Where they occur these references are for illustrative purposes only and do not 

represent an endorsement of a product or service by StarTech.com, or an endorsement of the 

product(s) to which this manual applies by the third-party company in question.  Regardless 

of any direct acknowledgement elsewhere in the body of this document, StarTech.com hereby 

acknowledges that all trademarks, registered trademarks, service marks, and other protected 

names and/or symbols contained in this manual and related documents are the property of 

their respective holders.

Summary of Contents for SV1631HD

Page 1: ...itung de startech com FR Guide de l utilisateur fr startech com ES Gu a del usuario es startech com IT Guida per l uso it startech com NL Gebruiksaanwijzing nl startech com PT Guia do usu rio pt start...

Page 2: ...ceiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer o...

Page 3: ...cade Configuration 2 Operating Your KVM Switch 2 Push Buttons 2 OSD Operations 3 OSD Function Keys 4 Hot Key Commands 7 Changing Your Configuration 9 Keyboard Mapping SV831HD SV1631HD only 9 Troublesh...

Page 4: ...StarTech com s 2 in 1 USB KVM cables or 3 in 1 PS 2 KVM cables SV1631D1U StarTech com s 3 in 1 PS 2 KVM cables Installation This section will guide you through the hardware installation of your KVM s...

Page 5: ...itch before turning on any of the others Operating Your KVM Switch To toggle between computers you can use the hot key commands OSD On Screen Display menu or by using the pushbuttons Push Buttons The...

Page 6: ...channel addresses names and status The port number or channel address of the currently selected computer is displayed in red in the top right of the screen The device name is green if the device has...

Page 7: ...racters are A to Z 0 to 9 and the dash character Lowercase letters are converted to uppercase Press BACKSPACE to delete a letter one at a time Non volatile memory stores all name entries until you cha...

Page 8: ...tops it then resumes with the next computer in sequence To abort Auto Scan mode press the left CTRL twice or press any front button Scan Type and Scan Rate set the scan pattern Scan Type F4 More Scan...

Page 9: ...Menu When you hit the left CTRL key twice within two seconds the Hotkey Menu appears displaying a list of hot key commands if the option is On The Hotkey Menu can be turned Off if you prefer not to s...

Page 10: ...nces and a low pitched beep for errors or bad key combinations that will not be carried out The short form hot key menu can be turned on as an OSD function F4 More Hotkey Menu every time the left CTRL...

Page 11: ...forth between power on computers left Ctrl left Ctrl F2 Press the up or down arrow to select the previous or next computer in sequence Press any other key to abort the Manual Scan Note Scan Type See...

Page 12: ...ny device either a KVM or a PC can be added or removed from any PC x port on the KVM without having to power down the Master KVM Switch Make sure that devices are turned off before connecting them to...

Page 13: ...right CTRL F3 Props right CTRL F4 Undo right CTRL F5 Front right CTRL F6 Copy right CTRL F7 Open right CTRL F8 Paste right CTRL F9 Find right CTRL F10 Cut Print Screen F13 Scroll Lock F14 Pause Break...

Page 14: ...he TFT LCD display are blurry or have shadows You may have improper resolution settings Under the Control Panel set the VGA output of your computers to match the highest resolution of the LCD monitor...

Page 15: ...en if the Master KVM has 16 PC ports Only one level of Slave KVMs is allowed Keyboard strokes are shifted Press both Shift keys Specifications SV831HD SV1631HD User Ports 1 1 Computer Ports 8 16 Casca...

Page 16: ...2 100 ft 30m at PC USB 16 ft 5m at PC VGA 1920x1440 DDC2B 1920x1440 DDC2B Computer connector 8 x HD DB 15 female 16 x HD DB 15 female Console Connectors Mouse Keyboard Monitor 1 x PS 2 female 1 x PS 2...

Page 17: ...with equivalent products at our discretion The warranty covers parts and labor costs only StarTech com does not warrant its products from defects or damages arising from misuse abuse alteration or no...

Page 18: ...ts and we quickly deliver them wherever they need to go Just talk to one of our tech advisors or visit our website You ll be connected to the products you need in no time Visit www startech com for co...

Reviews: