Starrett 5001B Series User Manual Download Page 2

2

LCD Display

Indicator of Min Max Mode

1. 

Indicator of Reference Mode

2. 

Measured value

3. 

Negative sign

4. 

Battery life warning display

5. 

Indicating cursor for Preset and Tolerance

6. 

Indicator of Measuring unit

7. 

Indicator of Tolerance Mode

8. 

Indicator of Preset Mode

9. 

Indicator of Set Mode

10. 

Indicator of Set Mode Display .0005" / .010mm

11. 

Hold indicator

12. 

Taking Measurements

Measurements can be taken from: SET, REF I, 
REF II, MIN / MAX, and TOLERANCE Modes

Mode

There are 5 Modes available: SET, REF 
I & REF II, PRESET, MIN / MAX, and 
TOLERANCE.

To change between Modes: 
Press and Hold 

MODE

Set Mode

Set Mode can calibrate / zero the tool to 
a Preset Reference Value (see Reference 
Mode), and to change the units-of-mea-
sure.

Note:

 If measurements are to be taken 

from this mode, the Hold function is not 
available, and when the SET key (also 
used as ZERO and HOLD) is pressed, the 
display will be zeroed to the REF I or II 
preset value.

To enter the Set Mode: 
 Press and Hold 

MODE

 until 

INCH/MM

 and 

SET

 appears

To change between MM / INCH: 
Press and Release 

MODE 

To calibrate / zero the tool: 
Press and Release 

SET

MEASUREMENTS CAN NOW BE TAKEN

Summary of Contents for 5001B Series

Page 1: ... replace with Lithium 3V CR2032 battery Changing the battery will automatically reset the indicator to factory defaults To remove the catridge slide the battery carrier 2 in the direction of the arrow in Fig 1 Remove the battery from the carrier and replace it with a fresh CR2032 battery Then slide the carrier back into the housing OPERATING INSTRUCTIONS Button Functions MODE and SET button operat...

Page 2: ...de There are 5 Modes available SET REF I REF II PRESET MIN MAX and TOLERANCE To change between Modes Press and Hold MODE Set Mode Set Mode can calibrate zero the tool to a Preset Reference Value see Reference Mode and to change the units of mea sure Note If measurements are to be taken from this mode the Hold function is not available and when the SET key also used as ZERO and HOLD is pressed the ...

Page 3: ... Values NOTE The recalled value depends on the REF MODE the tool is in Press and Hold MODE until INCH MM and SET appears Place the gage into the Gage Master Press and Release SET To go back to the Measurement Mode Press and Hold MODE until REF I or II appears MEASUREMENTS CAN NOW BE TAKEN ZERO RECALL Used to calibrate the gage to zero provided REF I or REF II preset value has been set to 0000 zero...

Page 4: ...il TOL appears To exit Tolerance Setting Mode Press and Hold MODE MEASUREMENTS CAN NOW BE TAKEN Measuring in Tolerance Mode To enter TOLERANCE MODE Press and Hold MODE until TOL appears MEASUREMENTS CAN NOW BE TAKEN Hold Used to hold a measurement value on the display Note Hold function is not available when in the Set Modes To Hold the reading Press and Release SET To release Hold Press and Relea...

Reviews: