10
ST 2400:
After operating the push-button, the appliance will run in
basic mode for about 30 sec.
Running time can be adjusted by turning the rotating pot-
entiometer inside the appliance. Only undertake adjustments
after removing the power lead from the mains!
STH 2400 Z:
After operating the push-button, the appliance will run in
basic mode for about 60 sec.
Running time can be adjusted by turning the rotating pot-
entiometer inside the appliance. Only undertake adjustments
after removing the power lead from the mains!
ST 2400 E, ST 2400 EC, ST 2400 ES:
These appliances are switched on and off without contact by
an infra red proximity switch.
The sensing range is between 0 mm and 200 mm.
To prevent continuous operation, e.g. if the sensor is short-
circuited, the appliance switches off automatically after
120 sec. Once the fault is corrected, the dryer is again ready
for operation.
Cleaning and servicing.
Clean the air inlet openings to remove sticking fluff and dust
as required with a narrow vacuum cleaner fitting. Remove
any dirt which is still stuck in the air inlet with a stiff brush.
The surface of the housing may be wiped over with a damp
or a dry cloth. Abrasive cleaners must not be used.
Symptom
Version
Possible causes and their remedies
Trouble-shooting.
Appliance will not
switch on
ST 2400,
STH 2400 Z
ST 2400 E,
ST 2400 EC
ST 2400 ES
Power supply is dead
p
check fuses/circuit breakers
Connecting cables loose or broken
p
switch off and remove from the power supply,
and test wiring connections and cables with a circuit tester.
if necessary, replace the timer electronic
Power supply is dead
p
check fuses/circuit breakers
Connecting cables loose or broken
p
switch off and remove
from the power supply, and test wiring connections and
cables with a circuit tester.
if necessary, replace the timer electronic with infra red sensor
While drying the appliance switches
off and cannot be immediately
restarted
All versions
Thermostat has triggered
p
allow appliance to cool down for a few minutes
and then switch on again
Motor runs, but blows
only cold air
All versions
Heating has failed
p
check the electric heating leads
with a circuit-tester in case of a broken wire
if necessary, replace the heating
The appliance fails to cut out
p
continuous operation
ST 2400,
STH 2400 Z
ST 2400 E,
ST 2400 EC
ST 2400 ES
When operated, the push-button sticks in
p
release the push-button again manually
Push-button does not spring back out and stays in
p
have the push-button replaced
Infra-red sensor does not switch off
p
replace the timer electronics with infra-red sensors
Infra-red sensor has been interfered with and is covered
p
remove the covering
Dryer is installed too close to an object and this object
reflects and switches the appliance on continuously
p
relocate either the dryer or the object
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
RS,TS, S.4-..ST2400/ST2400E 13.12.2005 13:20 Uhr Seite 10
Summary of Contents for AirStar ST 2400 E
Page 57: ...CN 56 RS TS S 4 ST2400 ST2400E 13 12 2005 13 21 Uhr Seite 56...
Page 59: ...58 RS TS S 4 ST2400 ST2400E 13 12 2005 13 21 Uhr Seite 58...
Page 60: ...59 RS TS S 4 ST2400 ST2400E 13 12 2005 13 21 Uhr Seite 59...
Page 61: ...60 RS TS S 4 ST2400 ST2400E 13 12 2005 13 21 Uhr Seite 60...
Page 62: ...61 RS TS S 4 ST2400 ST2400E 13 12 2005 13 21 Uhr Seite 61...
Page 65: ...64 RS TS S 4 ST2400 ST2400E 13 12 2005 13 21 Uhr Seite 64...
Page 66: ...65 RS TS S 4 ST2400 ST2400E 13 12 2005 13 21 Uhr Seite 65...
Page 67: ......