Battery Charging Status Indicators

Visual status indicators are displayed when 
a VFusion Battery is placed into the VFusion 
Charger, the battery drawer is closed, and 
a power source is provided. Each battery 
charges independently from the other, so it is 
possible for each battery to be in a different 
charging state.

LED behavior

Status

Notes

Slow-pulsing green 

Correctly charging 
VFusion Battery

Also applies to non-
rechargeable batteries or 
other foreign objects of 
similar size until they are 
detected and given an error 
condition

Continuous green 

Fully-charged 
VFusion Battery

Remains lit until drawer  
is opened or VFusion 
Charger is removed  
from power source

Cont.

Recharging VFusion Batteries at room 
temperature will optimize battery recharge 
time and improve battery longevity. If the 
VFusion Charger or VFusion Batteries are 
exposed to extremely hot or cold conditions 
(such as a parked vehicle), they may need 
to return to room temperature before 
successful charging can begin. The VFusion 
Charger automatically begins charging when 
temperature conditions are acceptable.

For a size 312 VFusion Battery, the charging 
time from a fully depleted state to full charge 
can be achieved in approximately six hours.  
The size 13 VFusion Battery takes slightly 
longer due to its additional capacity. If only  
a short amount of charging time is available,  
a quick charge (about one hour) can add up  
to 30 percent of the available capacity to  
the battery.

Summary of Contents for VFusion

Page 1: ...1 BC Rechargeable Hearing Aid Battery Charger ...

Page 2: ...r successful charging Sliding battery drawer Push and pop to click the USB cover closed LEDs provide visual feedback on battery charging progress Charging Typical charge time less than six hours Quick charging adds up to 30 percent of available capacity after one hour Cannot overcharge batteries VFusion Batteries do not experience a memory effect so they can be recharged at any time Power Source O...

Page 3: ...arger VFusion Batteries should be disposed of according to local state and or national regulations Package Contents VFusion Charger USB Cable USB Power Adaptor Note You must fold out the prongs on the back side of the USB Power Adaptor before plugging into the wall Safety Information Your VFusion Charger is capable of being powered by a variety of sources If you use a power source other than that ...

Page 4: ...er batteries or to metal objects In the rare event that a battery is leaking place the battery in a plastic bag prior to disposal and wash your hands afterwards with soap and water Warning Do not attempt to charge non rechargeable button batteries in this charger this includes both zinc air and silver oxide hearing device batteries ...

Page 5: ...9 6 VFusion Battery 7 USB protective cover VFusion Rechargeable Battery Charger Overview 1 Battery drawer 2 Battery compartment 3 LED indicator 4 USB plug 5 Battery size 312 or 13 identifier 4 2 3 5 7 6 1 ...

Page 6: ...Insert VFusion Charger directly into a computer USB socket 7 The VFusion Charger LED indicator will first briefly flash amber Verify the VFusion Charger LED indicator is slowly pulsing green for each battery inserted Figure 6 Quick Start 1 Pull battery drawer open Figure 1 2 Insert VFusion Battery into battery compartment Magnet should pull the battery into place Figure 2 3 Battery must lay flat a...

Page 7: ...ered USB socket the VFusion Charger automatically begins charging VFusion batteries When a VFusion Battery is fully charged the VFusion Charger automatically stops charging the battery It is not possible to overcharge a VFusion Battery VFusion Rechargeable Batteries sold separately VFusion Batteries are encased in a green band to highlight their rechargeability and make them easier to differentiat...

Page 8: ... VFusion Charger is removed from power source Cont Recharging VFusion Batteries at room temperature will optimize battery recharge time and improve battery longevity If the VFusion Charger or VFusion Batteries are exposed to extremely hot or cold conditions such as a parked vehicle they may need to return to room temperature before successful charging can begin The VFusion Charger automatically be...

Page 9: ...ironmental temperature exceeds 40 degrees C 104 F Charging automatically halted until temperature drops below 40 C Environmental temperature is less than 0 degrees C 32 F Charging automatically halted until temperature increases above 0 C Defective VFusion Battery Replace defective VFusion Battery with new VFusion Battery Fault condition detected in VFusion Charger Return VFusion Charger to hearin...

Page 10: ...18 19 Accessories Contact your Hearing Professional to purchase optional accessories USB Car Charger Adaptor Additional VFusion Rechargeable Batteries ...

Page 11: ...CES 3B NMB 3 B This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Advisory Information Warning This device charges small batteries that can be readily swallowed by children Keep this d...