TECHNICAL SPECIFICATIONS

SETUP AND INSTALLATION

This device must be placed on a horizontal, rigid and level surface that is capable of supporting the 

total weight of this device when filled with water. To prevent vibration or movement, place the device 

on an elastic base support like a rubber mat. For stationary use, this device can be screwed down 

firmly to the base with four screws. 

When being used on garden ponds or swimming pools, this device must be set up to guard against 

overflowing and protected from being submerged. 

the installation site must be well ventilated and protected against the effects of weather. If operating 

this device indoors, you must ensure there is a drain in the flooring or a leak detection mechanism. 

Before starting, check that the suction hose is sealed. Bubbles in the hose is an indication that there 

may be leaks and may lead to device malfunction. 

The suction line must be installed so that it does not exert any mechanical force 

or tension on the pump. If the conveying medium is contaminated, a suction 

filter must be used to pump from sand and dirt. 

NOTE

: A check valve is recommended so that the water does not run off when the pump is shut off. 

All connections must be sealed with fermit paste or thread sealing tape to prevent leaks that cause 

air exhaust and reduce or prevent water exhaust. 

Hemp should be used in case of pipe threads from metal; synthetic thread must be sealed with 

thread sealing tape. 

All components of the suction line must be installed by a qualified technician. 

The suction pipe should have an internal diameter of 25 mm and must be kink resistant and suitable 

for vacuum use. 
The suction line should be as short as possible, since the conveying capacity decreases as the 

length of the line increases. 

4

Summary of Contents for 71038

Page 1: ...NSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 71038 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Page 2: ...K This pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle Risk of electric shock This pump has not been investigated for use in swimming pool areas Electrical connections must beprotected from moisture If there is danger of flooding the electrical connections must be taken...

Page 3: ... supply corresponds with the connection specifications of the device before it is connected This pump may only be used within the specified limitations for voltage and power see the type plate Check the plug and cable before each use If the power cable is damaged immediately disconnect the plug Never use this device if the power cord is damaged Unplug the power cord when the device is not in use o...

Page 4: ...nternational safety health and working regulations Do not allow this device to get wet Do not leave this device unattended unplug the device when not in use Repairs should only be made by a qualified technician and or electrician Read and observe all safety instructions and warnings prior to using the device Never use this device near explosives or flammable materials COMPONENTS Install indoors or...

Page 5: ...ealed Bubbles in the hose is an indication that there may be leaks and may lead to device malfunction The suction line must be installed so that it does not exert any mechanical force or tension on the pump If the conveying medium is contaminated a suction filter must be used to pump from sand and dirt NOTE A check valve is recommended so that the water does not run off when the pump is shut off A...

Page 6: ... runs out evenly switch the device off For better performance installing a check line valve between the pump and suction line is recommended so that the water column remains in the suction line If Domestic Water Works is installed directly in the water distribution network it is important that the water pressure from this network is added to the pump pressure A total pressure of 6 bar must not be ...

Page 7: ...onnection and pressure gauge 4 Pump up or inflate to the designated preliminary filling pressure Preliminary filling pressure 1 8 2 0 bar Unscrew filter housing A and take out the filter cartidge If necessary soak the cartridge in warm water Rinse the filter cartidge with clean water brush out stubborn dirt from inside the cartridge using a soft brush DANGER If the conveyed water is highly contami...

Page 8: ...TROUBLESHOOTING 7 ...

Page 9: ...PRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial n...

Reviews: