background image

3

IMPORTANT SAFETY INFORMATION

USE OF AN EXTENSION CORD IS NOT RECOMMENDED

. If you choose to use an extension cord, 

use the following guidelines:

Make sure your extension cord is in good condition.

Be sure to use an extension cord which is heavy enough to carry the current your product will draw. 

An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Table A 

shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt,

use the next heavier gauge. The smaller the gauge number, the heavier the cord.
Industrial applications must follow OSHA guidelines.

Maintain labels and nameplates on the compressor. These carry important safety information. If 

unreadable or missing, contact Stark Tools for a replacement.

Operate unit on level surface. Check oil level daily and fill to marked level if needed.

People with pacemakers should consult their physician(s) before use. Electromagnetic fields in

close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.

TO PREVENT ELECTRIC SHOCK AND DEATH FROM INCORRECT GROUNDING WIRE 

CONNECTION:

 Check with a qualified electrician if you are in doubt as to whether the outlet is 

properly grounded. Do not modify the power cord plug provided with the compressor. Never remove 

the grounding prong from the plug. Do not use the compressor if the power cord or plug is damaged. 

if damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a 

proper outlet installed by a qualified electrician.

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric 

current to reduce the risk of electric shock. This compressor is equipped with an electric cord having 

an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching 

outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DO NOT 

modify the plug provided – if it will not fit the outlet, have the proper outlet installed by a 

qualified electrician.

Improper connection of the equipment-grounding conductor can result in a risk of electric shock.

The conductor with insulation having an outer surface that is green with or without yellow stripes is the 

equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do 

not connect the equipment grounding conductor to a live terminal.

Summary of Contents for 65151

Page 1: ...G INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 65151 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 4900 MON FRI 9AM TO 3PM PST ...

Page 2: ...developed a thorough understanding of how it works DO NOT modify this product in any way Unauthorized modification may impair the function and or safety and could affect the life of the product There are specific applications for which the product was designed Inspect the work area before each use Keep work area clean dry free of clutter and well lit Cluttered wet or dark work areas can result in ...

Page 3: ...ed repair person using only identical replacement parts This will ensure that the safety of the compressor is maintained Risk of fire or explosion do not spray flammable liquid in a confined area or towards a hot surface Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present parts keep compressor at least 20 feet away from explosive vapors such as w...

Page 4: ...TION Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded Do not modify the power cord plug provided with the compressor Never remove the grounding prong from the plug Do not use the compressor if the power cord or plug is damaged if damaged have it repaired by a service facility before use If the plug will not fit the outlet have a proper outlet ins...

Page 5: ...mpressor Head 3 Using the Sight Glass built into the lower front area of the compressor just behind the regulator check the oil level It should be at the halfway mark on the sight glass for operation If it is necessary to add oil use any standard compressor oil available at major retailers 4 There are two Air Outlet fittings on the regulator Air flow for one fitting is operated by turning the regu...

Page 6: ...nt injury 2 Check for oil leaks and check the oil level 3 Close the in line shut off valve between the compressor and the air hose 3 Close the in line shut off valve between the compressor and the air hose 4 Turn the power switch ON 5 Allow the air compressor to build up pressure until it cycles off 3 5HP Made with Durable Cylinder 10 Gal Long Life with Oil lubricated motor Delivers 7 2 CFM 40 PSI...

Page 7: ... at any time Turn the Regulator clockwise to increase the pressure and counter clockwise to decrease pressure Adjust the pressure gradually while checking the Output Pressure Gauge to set the pressure DISCHARGE VALVE SAFETY VALVE ADJUSTING SCREW BREAKING IN THE COMPRESSOR 1 Turn the Power Switch off and unplug the unit Insert a male coupler sold separately into the female Quick Coupler and fully o...

Page 8: ... OFF Then pull on the ring on the Safety Valve to quickly release stored air pressure CLEANING MAINTENANCE AND LUBRICATION BEFORE EACH USE Inspect the general condition of the air compressor Check for the following Loose hardware Misalignment or binding of moving parts Cracked or broken parts Damaged electrical wiring Any other condition that may affect safe operation AFTER EACH USE Wipe external ...

Page 9: ... Remove the Oil Breather Plug to allow air flow into the Pump 3 Remove the Oil Sight Gauge ans allow the oil to drain into the container 4 When the oil is completely drained from the pump reinstall the Oil Sight Gauge 5 Fill the pump with new 30W non detergent air compressor oil to the FULL level on the sight gauge 6 Discard the old oil according to local state and federal regulations AIR FILTER M...

Page 10: ...TROUBLESHOOTING WARNING Follow all safety precautions whenever diagnosing or servicing the compressor Disconnect the power supply before service 9 ...

Page 11: ...PARTS LIST LIST OF GOODS 10 ...

Page 12: ...PARTS DIAGRAM 11 ...

Page 13: ...THER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY T...

Reviews: