4)

Carefully remove the secondary mirror assembly from the front of the telescope.  Do 
not touch the surface of the mirror itself.

5)

Place the secondary mirror assembly into the holder.  Note the notch on the side of 
the   secondary   holder   which   accepts   the   small   screw   on   the   side   of   the   mirror 
assembly.  Use the original retaining ring to lock the mirror assembly in place.

Attaching the CCD Camera

6)

Some CCD cameras require threaded adapters.   Begin by removing the plastic cap 
from the top (narrow end) of the HyperStar lens and attaching any required adapters.

7)

The CCD camera will attach to the HyperStar (or adapter) using T-threads.   Most 
cameras have a 1.25” or 2” nosepiece that must be removed to allow the HyperStar to 
thread into the T-threads.

Summary of Contents for HyperStar C8 HD

Page 1: ...amera are mounted on the telescope there is the potential for damaging the corrector plate if caution is not exercised at all times Be especially careful not to bump the CCD camera or HyperStar lens while they are attached to the telescope Also be sure that all cables from the CCD camera are properly tied off to prevent them from pulling on the camera and lens Additional tips and warnings are clea...

Page 2: ...m falling out during installation Removing the Secondary Mirror 2 The secondary mirror holder doubles as the bottom cap for the HyperStar lens Begin by unthreading the holder to remove it from the lens Holder capping the HyperStar Holder removed to accept secondary mirror 3 Unthread the retaining ring from the secondary mirror holder as shown below ...

Page 3: ... side of the mirror assembly Use the original retaining ring to lock the mirror assembly in place Attaching the CCD Camera 6 Some CCD cameras require threaded adapters Begin by removing the plastic cap from the top narrow end of the HyperStar lens and attaching any required adapters 7 The CCD camera will attach to the HyperStar or adapter using T threads Most cameras have a 1 25 or 2 nosepiece tha...

Page 4: ...8 Thread the CCD camera onto the HyperStar lens 9 Carefully thread the entire assembly into the front of the telescope Camera orientation can be changed later ...

Page 5: ...s slightly tilted and not perfectly aligned with the optical axis of the HyperStar This is normally compensated by adjusting the secondary mirror but with the mirror removed it now needs to be compensated for with the HyperStar The easiest method is to take a single short exposure of a star field 1 3 seconds is usually enough Make an adjustment by loosening one of the pull screws shown below and t...

Page 6: ...tly The nylon bushings will allow the lens to rotate with the screws still somewhat snug Once the camera and lens are in the desired orientation tighten down the screws Using Filters 1 Unthread the top half of the filter adapter from the HyperStar lens 2 Thread the filter into the inside of the top half of the filter adapter 3 Thread the top half of the adapter back onto the HyperStar and you are ...

Page 7: ...53 3 2 20 pixel Starlight Xpress SXVR H9C 72 8 x 54 2 3 13 pixel Starlight Xpress SXVR M25C 189 3 x 126 2 3 78 pixel Exposure Factors Equivalent Exposure Times Focal Ratio Exposure Factor Example Exposures f 2 1 HyperStar C8 HD 1 30 seconds f 3 3 2 5 1 2 minutes f 5 5 7 2 8 minutes f 6 3 9 4 5 minutes f 10 23 11 3 minutes Starizona 5757 N Oracle Rd Suite 103 Tucson AZ 85704 520 292 5010 www stariz...

Reviews: