Stardex 0501 Manual Download Page 6

 

 

Menu window 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pulses  count  button

  –  pulses  counter  changes  the  number  of  measurements  values 

(500, 1000, 2000) 

Number of measurements

 – the number of accomplished injections after which delay 

time counting will be finished. 

Markers of keyboard control

 – are used for backlight of the selected menu item.  

Navigation buttons

 – are used for selection of menu items. 

Exit button 

– exits to the main window with saving all the made changes. 

Enter button 

– is used for activation of the selected menu item. 

Sensitivity settings button 

– opens the window of sensitivity settings. 

Pulses count button

 

 

Number of 
measurements

 

 

Markers of 
keyboard control

 

 

Sensitivity settings 
button

 

 

Exit button 

 

Navigation 
buttons 

Exit button 

Enter 
button 

Summary of Contents for 0501

Page 1: ...INJECTION EXPLORER STARDEX 0501...

Page 2: ...ately unplug it and send to the service center All cables from the delivery kit must be supplied with standard plugs and do not have mechanical damage The device does not contain self repairable parts...

Page 3: ...memory that allows making a comparative analysis of the characteristics of all injectors mounted on the engine and making the necessary adjustments 4 Switching on off the device connectors 1 Connect p...

Page 4: ...me on the graph 5 Interface description and control buttons Main window RPM the number of injections per minute equal to the revolutions of the CamBox shaft if UIS is tested Average delay time average...

Page 5: ...you back to the main window of the device from the menu or exit from the submenu to the menu with saving all the made changes Navigation buttons are used for navigation in the menu and also to move b...

Page 6: ...or backlight of the selected menu item Navigation buttons are used for selection of menu items Exit button exits to the main window with saving all the made changes Enter button is used for activation...

Page 7: ...y time measurements of very small or very large fuel delivery modes Sensitivity settings graph the curve on the graph schematically shows the level of injection sensor signal and the horizontal line s...

Page 8: ...itivity threshold of injection sensor Navigation buttons change the sensitivity threshold more less Exit button saves all changes made in the sensitivity settings window and exits to the menu window S...

Page 9: ...signal wires of the injector using universal adapter or probe so that the signal from the pulse simulator to the injectors comes both on the injector and on the device Start the injector testing on t...

Page 10: ...pc Universal cable adaptor 1 1 pc Universal cable adaptor 2 1 pc Universal cable adaptor 3 1 pc Probes for getting the signal from injector cables 2 pc Injection sensor 1 pc Fuel disperser d 7 mm 1 pc...

Page 11: ...e for the damage due to violation of the operation terms misuse including unskillful or mistaken personnel actions and if there are traces of mechanical impact 9 Package The product is packed into bub...

Reviews: