GENERAL INSTALLATION DATA

This equipment is designed and sold for commercial use only by personnel trained and 

experienced in its operation and is not sold for consumer use in and around the home nor 

for use directly by the general public in food service locations. 
The Star series gas vertical broiler is equipped for the type of gas indicated on the 

nameplate mounted on the unit. All gas units are shipped from the factory for use with 

natural gas.

-IMPORTANT-

Be sure to remove all paper protection and packing material from unit prior to 

lighting.

This appliance should be installed in a non-combustible location only.

The installation of the Appliance must conform to the NATIONAL FUEL GAS 

CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY 

RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE 

CURRENT CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR 

CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES 

WHERE APPLICABLE.

NOTICE

For your protection, we recommend a qualified installing agency install this appliance. 

They should be familiar with gas installations and your local gas requirements. In any 

case, your gas company should be called to approve the final installation. 

This appliance, its pressure regulator and its individual shutoff valve must be disconnected 

from the gas supply piping system during any pressure testing of that system at test 

pressures in excess of 1/2 PSIG. This appliance and its pressure regulator must be isolated 

from the gas supply piping system by closing its individual manual shutoff valve during 

any pressure testing (5" WC NAT, 10" WC LP) using the 1/8"NPT fitting on the gas supply 

piping system at test pressures equal to or less than 1/2 PSIG.

EXHAUST CANOPY

Open broilers inherently create a good deal of heat and smoke and should be installed 

under an efficient exhaust hood with flame proof filters. A vertical distance of not less than 

48" shall be provided between the top of the appliance and filters or any other combustible 

material.  Exhaust installation must conform to local codes.

CAUTION

Summary of Contents for VBE30

Page 1: ...any other appliance WARNING This appliance shall be installed in accordance with current regulations and used only in well ventilated space Refer to instructions before installing and using this appl...

Page 2: ...or errors or omissions in information provided or conclusions provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Contact your local authorized service agent for se...

Page 3: ...ut BTU s KW Total Amps Plug Type Aproximate Weight Shipping Installed VBE30 16 08 24 97 32 208V 4 5 21 6 NEMA 6 30P 60 70 230V 4 2 18 2 240V 4 5 18 8 NEMA 6 30P VBG30 40 79 63 42 81 28 120V NAT 30 000...

Page 4: ...ES WHERE APPLICABLE NOTICE For your protection we recommend a qualified installing agency install this appliance They should be familiar with gas installations and your local gas requirements In any c...

Page 5: ...remove heat and cooking odors The hood and HVAC installation must meet local codes to gain approval by the authority having jurisdiction Requirements may vary throughout the country depending on the l...

Page 6: ...hutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure in excess of PSIG This appliance and its individual manual shutoff valve...

Page 7: ...ockwise for the section to a position of ON or close to it For holding or finishing turn the valves closer to the LO position on the dial You select the heat pattern you like and set the valves accord...

Page 8: ...orized service agency Star will not be responsible for charges incurred or service performed by non authorized repair agencies In all cases the nearest Star authorized service agency must be used Star...

Page 9: ...12 11 8 13 14 ELECTRIC BROILER WIRING DIAGRAM Z13920 PILOT LAMP TERMINAL BLOCK SEE NAMEPLATE FOR VOLTAGE SUPPLY WIRES FOR SUPPLY USE COPPER CONDUCTORS RATED FOR 75 C MINIMUM POWER CORD WHT BLK GRN TER...

Page 10: ...al to Star Manufacturing International Inc No reproduction or disclosure of it s CERTAIN INSTANCES MAY NOT BE AVAILABLE ILLUSTRATIVE PURPOSES ONLY AND IN SOME ITEMS ARE INCLUDED FOR contents is permit...

Page 11: ...COLLAR MOTOR 1 11 K8 Z13908 MOTOR SUPPORT BRACKET 1 12 2P Z13918 RETURN SPRING 1 13 K8 Z13912 SLIDE SUPPORT BRACKET 2 14 2U Z13886 MOTOR 208 240V 1 16 2E 30900 15 FUSE 3 AMP AGC 2 17 2E 30901 02 FUS...

Page 12: ...12 MODEL VBG Gas Vertical Broiler SK2567 Rev A 12 17 2014 1 7 9 12 13 14 15 27 28 29 30 31 32 33 34 35 36 37 16 25 20 17 21 22 23 24 19 18 2 26 2 10 38 39 11 40 41 6 8 2 3 2 5 4...

Page 13: ...RAIL BRACKET 19 K8 Z13908 1 MOTOR SUPPORT BRACKET 20 2A Z13899 1 DRIVE COLLAR MOTOR 21 2C Z13887 1 SHOULDER SCREW 8X32 TH 22 K8 Z13910 1 MOTOR PULL BAR 23 2I Z14377 1 END CAP FLAT GRIP 3 4 24 2P Z1391...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16 STAR MANUFACTURING INTERNATIONAL INC Star Holman Lang Wells Toastmaster 265 HOBSON ST SMITHVILLE TN 37166 800 264 7827 www star mfg com...

Reviews: