GENERAL INSTALLATION DATA

CAUTION

This equipment is designed and sold for commercial
use only by personnel trained and experienced in its
operation and is not sold for consumer use in and
around the home nor for use directly by the general
public in food service locations. For equipment to be
used by the general public, please contact the factory.

The Star-Max™ model griddles are equipped for use
with the types of gas specified on the nameplate.

-IMPORTANT-

The installation of the Appliance should
conform to the NATIONAL FUEL GAS
CODE "ANSI Z223.1 - LATEST EDITION"
AND ALL LOCAL GAS COMPANY RULES
AND REGULATIONS.

CAUTION

Improper installation, adjustment, alteration,
service or maintenance can cause property
damage, injury or death. Read the installation,
operating and maintenance instructions
thoroughly before installing or servicing the
equipment.

CAUTION

For your safety, do not store or use gasoline or
other flammable vapors and liquids in the
vicinity of this or any other appliance.  Keep the
appliance area clear and free from combustibles.

This appliance, its pressure regulator and its individual
shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 PSIG
(3.45KPA). This appliance and its pressure regulator
must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 PSIG (3.45KPA).

For your protection, we recommend a qualified
installing agency install this appliance. They should
be familiar with gas installations and your local
gas requirements. In any case, your gas company
should be called to approve the final installation.
In addition, there should be posted, in a prominent
location, detailed instructions to be followed in
the event the operator smells gas. Obtain the
instructions from the local gas supplier.

CAUTION

For your safety, if you smell gas:
1. Do not touch electrical switches.
2. Extinguish any open flame.
3. Immediately call your gas company.

CLEARANCE
For use on non-combustible countertops only

.

Combustible and non-combustible material must be
at least 48" (120cm) from the top of the appliance and
6" (150mm) from the sides and back. Adequate
clearance should also be provided for proper operation
and servicing.

AIR SUPPLY

Make certain not to obstruct the flow of combustion
and ventilation air.  Make certain that air intake openings
in the bottom of the appliance are not obstructed.
They are essential for proper combustion and operation
of the appliance.

Summary of Contents for STAR-MAX 8G-624MZ-LP

Page 1: ...0 Sunnen Drive St Louis MO 63143 Phone 314 781 2777 Fax 314 781 3636 Installation and Operating Instructions STAR MAX PROPANE GAS GRIDDLE MODELS 8G 624MZ LP 8G 636MZ LP 8G 648MZ LP 8G 624TZ LP 8G 636T...

Page 2: ...0 lbs 158 8 kg Dimensions 48 W x 27 3 4 D x 13 1 2 H 121 9 cm W x 70 5 cm D x 34 3 cm H 8G 624TZ LP Type Thermostat Control 2 Controls 40 000 BTU 498 sq in 3213 4 sq cm Grid Area 3 4 1 9 cm Plate Thic...

Page 3: ...ions and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously pur chased equipment MAINTENANCE AND REPAI...

Page 4: ...system at test pressures in excess of 1 2 PSIG 3 45KPA This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve durin...

Page 5: ...or and thermostat will occur GAS PIPING Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to meet the full gas inputoftheappliance Iftheapplianceistobeconnecte...

Page 6: ...wait 5 minutes to clear gas 2 Turn off all knobs and pilot valves and wait 5 minutes to clear gas 3 Turn on main valve and light all pilots 4 Turn burner knobs to desired setting 5 To turn burners off...