![Star STAR-MAX 502FZ Manual Download Page 4](http://html1.mh-extra.com/html/star/star-max-502fz/star-max-502fz_manual_1361578004.webp)
4
CLEANING
The exterior surfaces can be kept clean and attractive
by regularly wiping with a clean soft cloth. Any
discoloration can be removed with a non-abrasive
cleaner.
For model 502Z, the heating elements may be raised
for access to the drip pans, which may be removed for
cleaning and the bottom pan may be removed by
sliding pan forward.
REPLACEMENT OF INFINITE CONTROL
BE SURE POWER IS DISCONNECTED
BEFORE ATTEMPTING TO SERVICE UNIT.
1. Pull control knobs on front panel forward to
remove.
2. Remove 4 screws from front panel and tilt front
panel forwards.
3. Remove the nut that mounts the inoperative
control and pull the control to the side.
4. Remove one wire at a time from the inoperative
control and connect at the same terminal on the
new control. Carefully check to see that proper
wires have been connected to the terminals of the
control. See attached wiring diagram.
5. Assemble new control to the front panel.
MAINTENANCE AND REPAIRS
Contact the factory or one of its representatives or a
local service company for service or maintenance if
required.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
Part No. 2M-Z1436
Rev. C 1/8/03