The maximal electric current of the solar air conditioner refers to the maximal
input electric current, which is printed on the brand of the indoor unit. The maximal
electric current of the circuit refers to the total summation of the maximal electric current,
which comprises the maximal electric current of the solar air-conditioner and the
maximal electric current of other appliance.
The electric security requirement of installation of solar air conditioner
1. Power cord of indoor and outdoor units cannot adopt polyvinyl chloride, and
must adopt chloroprene rubber wires (including high-tension signal wires). It is
forbidden to lengthen or shorten the wires by yourself. The exceedingly long
wire of electric source should be folded as large round curves. It is strictly forbidden to
wind wires into small circles.
2. The ground wire must adopt yellow and green wires with adequate wire size. The
ground wire is strictly prohibited to connect to pipe of tap water, pipe of coal gas, zero lin
e of electric source, and overhead ground wire.
3. When you connect wires, please refer to the electric circuit diagram in the machine
and ensure everything is correct.
Please install the air conditioner at a place, which is provided with following
characteristics.
1
1
1
1
)
IIIIndoor
ndoor
ndoor
ndoor U
U
U
Unit
nit
nit
nit
①
Indoor unit should be installed upon a firm vibrationless wall.
②
Entrance and vent are supposed to be expedited. The hot wind and the cool wind
are supposed to should blow toward all around the room.
③
Indoor unit should be installed where it is convenient to connect with the outdoor
unit.
④
Indoor unit Installation should avoid direct solar radiation.
⑤
Indoor unit should be installed where drainage is convenient.
⑥
Indoor unit Installation should consider about future maintenance. The filter screen
should be dismountable.
⑦
Indoor unit Installation should ensure the spaces which are shown in the following
picture.
2
2
2
2
)
O
O
O
Outdoor
utdoor
utdoor
utdoor U
U
U
Unit
nit
nit
nit
*
Outdoor unit should be installed on
the solid foundation, because the infirm
foundation will increase noise and libration.
*
Please ensure that no barrier blocks
the vent.
*
At the seaside, please do not install
the outdoor unit at a high altitude where the
sea wind is more forceful. To ensure the
fan work normally, the solar air conditioner should be arranged tightly upon the wall. A
baffle is to be adopted.
*
Preventing wind blows to the inside of solar air conditioner, epically in places
where the wind is particularly strong.
*
Any barriers, which may block spreading heat, should be removed.
*
If you adopt hanging installation, the wall should be composed of solid brick,
concrete, or other equally firm structure. Otherwise, please reinforce, stabilize, and
secure the solar air conditioner installation. Slip, overturn and drop should be avoided.
≦
10
1 or 1.5
16/16
≦
16
1.5
~
4
32/25
≦
16
1.5 or 2.5
32/25
≦
25
2.5
~
4
63/50
≦
25
2.5 or 4
63/50
≦
32
4
~
10
63/50
≦
32
4 or 6
63/50
≦
40
6
~
16
100/80
≦
63
10
~
25
125/125
The ceiling
More than 40 cm
More than 20cm
More than 20cm
Hanging plate
Left
Right
right