Star Progetti ATEX EHSAFE15 Operating Instructions Manual Download Page 4

IMPORTANT  NOTICE:  TO  PREVENT  OVERHEATING  OF  THE  BULB,  THE  EXTERNAL  SURFACE  OF  THE  GLASS  MUST 
ALWAYS BE KEPT CLEAN DISCONNECT POWER SUPPLY BEFORE CLEANING

* Connect  Helios  Safe  Industry  to  a  220-240V  power  source,  single-phase,  according  to  the  country  in  which  the
appliance is used
* Helios Safe Industry must be connected to an earth connection system
* Check that the input power is appropriate for the electrical load to be installed

* THE APPLIANCE MUST ALWAYS BE INSTALLED HORIZONTALLY

* Do not cover or obstruct the appliance when operating

INSTALLATION/ SETTING AT WORK

These  appliances  can  be  installed,  connected  and  set  at  work  only  by  qualified  persons.  These  persons  must  be 
familiar with the types of anti-ignition protection, the regulations and the rules applying to the means of production 
in the zone exposed to the risk of explosion. Check if the class (see the “Specifications” section above and the label 
on the appliance) is suitable for specific use of the appliance.

INSTRUCTIONS FOR INSTALLATIONS/ASSEMBLY
The appliance must always be installed horizontally

Proceed in accordance with current regulations and national provisions and the pertaining instructions provided by 
the manufacturer. Protect the appliances and cables to prevent all possible damage. Attach the appliance to the wall 
at a minimum distance of 30 cm from the ceiling (see installation illustrations). The height at which the appliance is to 
be installed generally ranges from 2.0 m to a maximum 3.5 m. Wall installation ensures an ideal position for optimal 
heating results, at a tilt angle of 45° (the appliance must be 

perfectly horizontal

). The appliance can also be installed 

on the ceiling, with chains (not supplied).

POSITIONING

Point the Helios Safe Industry reflector beam as required during wall installation. Normally the appliance is tilted at 
approx. 45° with respect to the horizontal line. Never install Helios SafeIndustry on a flammable surface or direct it 
toward a a flammable surface. The appliance must be positioned at a distance (line of sight) of no less than 2.0 m, 
unencumbered, from objects such as cardboard, fabrics, curtains etc. or, likewise, from glass panes.

      Make sure that the bracket is correctly attached and fixed to the wall. [---]

MAINTENANCE:  (The  appliance  is  sealed,  also  with  lead.  Opening  the  appliance  or  tampering  with  it  is  not 
permitted).

CLEANING THE GLASS AND DUSTING THE APPLIANCE

Before  cleaning/dusting  the  appliance,  make  sure  the  atmosphere  has  been  rendered  non-explosive.  When  the 
atmosphere cannot be rendered non-explosive, please note that operations in such environments can only be carried 
out by qualified personnel, trained in regard to the specific risks. Such persons must also be provided with protection 
devices (e.g. spark-proof tools etc.).

LAYERS OF DUST

Deposited dust will reduce the appliance’s capacity to dissipate heat and will therefore raise surface temperatures to 
a level at which deposited combustible dust may, in certain circumstances, be ignited. To prevent such risks, the user 
must plan cleaning of the heater so that it shall be as dust-free as possible.

PLEASE NOTE

Periodic maintenance of the heater is vitally important in order to constantly ensure appliance safety over time in 
regard to the risk of explosions. The user must therefore proceed in conformity with the maintenance table included 
in the pertaining chapter of the directions handbook.

9

Summary of Contents for ATEX EHSAFE15

Page 1: ...OPERATING INSTRUCTIONS HELIOS SAFE INDUSTRY ATEX 1500 Watt COD EHSAFE15 2000 Watt COD EHSAFE20 ...

Page 2: ...uffed anodically oxidized aluminium parabolic reflector Front ceramic glass Silicone rubber seal Supply cable length 1 5 m and resistant to Temperature 180 C Adjustable wall anchorage WARNING PLEASE NOTE THIS HEATER IS SUITABLE FOR INSTALLATION IN EXPLOSIVE ATMOSPHERE CONDITIONS CLASSIFIED ZONE 2 22 PURSUANT TO DIRECTIVES 94 9 AND 99 92 EC ATEX ZONE 2 22 indicates that the atmosphere which is norm...

Page 3: ...work The symbols included below indicate safety measures and supplementary instructions in these operational directions SPECIAL SAFETY INSTRUCTIONS AND GUARANTEE PLEASE NOTE To prevent damage to objects and personal injury users must proceed strictly in accordance with the safety measures and supplementary instructions contained in these operational directions PLEASE NOTE DO NOT SET THIS HEATER AT...

Page 4: ...must be perfectly horizontal The appliance can also be installed on the ceiling with chains not supplied POSITIONING Point the Helios Safe Industry reflector beam as required during wall installation Normally the appliance is tilted at approx 45 with respect to the horizontal line Never install Helios SafeIndustry on a flammable surface or direct it toward a a flammable surface The appliance must ...

Page 5: ... DIAGRAM 10 ...

Page 6: ...WALL INSTALLATION PLEASE NOTE THE APPLIANCE MUST ALWAYS BE INSTALLED HORIZONTALLY AS ILLUSTRATED IN THE DRAWING ANCHORAGE REAR JOINT DETAIL CEILING INSTALLATION 11 ...

Page 7: ...www heatxl com atex infrarood verwarming html ...

Reviews: