OPERATING INSTRUCTIONS
HELIOS SAFE INDUSTRY ATEX
1500 Watt COD. EHSAFE152000 Watt COD. EHSAFE20
Page 1: ...OPERATING INSTRUCTIONS HELIOS SAFE INDUSTRY ATEX 1500 Watt COD EHSAFE15 2000 Watt COD EHSAFE20 ...
Page 2: ...uffed anodically oxidized aluminium parabolic reflector Front ceramic glass Silicone rubber seal Supply cable length 1 5 m and resistant to Temperature 180 C Adjustable wall anchorage WARNING PLEASE NOTE THIS HEATER IS SUITABLE FOR INSTALLATION IN EXPLOSIVE ATMOSPHERE CONDITIONS CLASSIFIED ZONE 2 22 PURSUANT TO DIRECTIVES 94 9 AND 99 92 EC ATEX ZONE 2 22 indicates that the atmosphere which is norm...
Page 3: ...work The symbols included below indicate safety measures and supplementary instructions in these operational directions SPECIAL SAFETY INSTRUCTIONS AND GUARANTEE PLEASE NOTE To prevent damage to objects and personal injury users must proceed strictly in accordance with the safety measures and supplementary instructions contained in these operational directions PLEASE NOTE DO NOT SET THIS HEATER AT...
Page 4: ...must be perfectly horizontal The appliance can also be installed on the ceiling with chains not supplied POSITIONING Point the Helios Safe Industry reflector beam as required during wall installation Normally the appliance is tilted at approx 45 with respect to the horizontal line Never install Helios SafeIndustry on a flammable surface or direct it toward a a flammable surface The appliance must ...
Page 5: ... DIAGRAM 10 ...
Page 6: ...WALL INSTALLATION PLEASE NOTE THE APPLIANCE MUST ALWAYS BE INSTALLED HORIZONTALLY AS ILLUSTRATED IN THE DRAWING ANCHORAGE REAR JOINT DETAIL CEILING INSTALLATION 11 ...