Star Manufacturing STAR-MAX 6015CBSB Installation And Operating Instructions Manual Download Page 3

3

GENERAL INSTALLATION DATA

CAUTION

This equipment is designed and sold for commercial
use only by personnel trained and experienced in its
operation and is not sold for consumer use in and
around the home nor for use directly by the general
public in food service locations. For equipment to be
used by the general public, please contact the factory.

The Star-Max series gas charbroiler is equipped for the
type of gas indicated on the nameplate mounted on
the  front panel. All units are shipped from the factory
for use with natural gas. The unit can easily be converted
for use with propane gas: see propane gas.

-IMPORTANT-

INSTALLATION: INSTALL IN NON-COMBUSTIBLE
LOCATIONS ONLY! Clearance from non-
combustible construction must be 6" from back and
sides.

The installation of the Appliance must conform
to the NATIONAL FUEL GAS CODE "ANSI
Z223.1 - LATEST EDITION" AND ALL LOCAL
GAS COMPANY RULES AND
REGULATIONS.

IN CANADA INSTALLATION SHALL BE IN
ACCORDANCE WITH THE CURRENT
CAN/CGA-B149.1 NATURAL GAS
INSTALLATION CODE OR CAN/CGA-
B149.2 PROPANE INSTALLATION CODE
AND LOCAL CODES WHERE APPLICABLE.

WARNING

: Improper installation,

adjustment, alteration, service or maintenance
can cause property damage, injury or death.
Read the installation, operating and
maintenance instructions thoroughly before
installing or servicing the equipment.

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE. KEEP THE
APPLIANCE AREA CLEAR AND FREE FROM
COMBUSTIBLES.

This appliance, its pressure regulator and its individual
shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 PSIG. This
appliance and its pressure regulator must be isolated
from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the
gas supply piping system at test pressures equal to or
less than 1/2 PSIG. For your protection, we recommend
a qualified installing agency install this appliance. They
should be familiar with gas installations and your local
gas requirements. In any case, your gas company
should be called to approve the final installation. In
addition, there should be posted, in a prominent
location, detailed instructions to be followed in the
event the operator smells gas. Obtain the instructions
from the local gas supplier.

LEVELING UNIT

This charbroiler is supplied with 4 feet which must be
screwed into the body. Level unit by adjusting the (4)
feet which have an adjustment of 1-3/4" for accurate
and perfect line-up with other units.

CAUTION

DO NOT INSTALL WITHOUT ATTACHING
FEET - DO NOT REMOVE FEET.

GAS INPUT TO CHARBROILER:

Models 6015CBSB:

40,000/35,000 BTU/HR NAT/PROP

Models 6024CBSB and 6124RCBSB:

80,000/70,000 BTU/HR NAT/PROP
40,000/35,000 BTU/HR/BURNER NAT/PROP

Models 6036CBSB and 6136RCBSB:

120,000/105,000 BTU/HR NAT/PROP
40,000/35,000 BTU/HR/BURNER NAT/PROP

Summary of Contents for STAR-MAX 6015CBSB

Page 1: ...nal Inc 10 Sunnen Drive St Louis MO 63143 Phone 314 781 2777 Fax 314 781 3636 Installation and Operating Instructions 2M Z3289 Rev A 2 26 03 STAR MAX GAS CHARBROILER MODELS 6015CBSB 6024CBSB 6036CBSB 6124RCBSB and 6136RCBSB 6024CBSB ...

Page 2: ...pecifications and product design without notice Such revisions do not entitle the buyer to corre sponding changes improvements additions or replacements for previously purchased equipment MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance Refer to the authorized service center listing provided with the unit The Star Service Help Desk 1 800 807 9...

Page 3: ... OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE KEEP THE APPLIANCEAREACLEARANDFREEFROM COMBUSTIBLES This appliance its pressure regulator and its individual shutoff valve must be disconnected from the gas supplypipingsystemduringanypressuretestingofthat system at test pressures in excess of 1 2 PSIG This appliance and its pressure regulator must be isolated fromt...

Page 4: ...oods supplied 3 Replace the burners radiants and grill 4 Set manifold pressure to 10 inch water column A 1 8 pipe plug on the burner manifold can be removed for attaching a pressure gauge Remove theslotted orhex threadedplugfromthepressure regulator Invert the plug and re install The letters LP should now be visible on the plug The regulator is now set for 10 25 4 cm water column CHECKING FOR GAS ...

Page 5: ...s or gloves to reposition CAUTION CHARBROILERS ARE HOT NEVER ATTEMPT TO CHANGE THE GRILL POSITION WHILE MEATPRODUCTSARECOOKING FLAREUPS CAN OCCUR UNEXPECTEDLY TURN OFF CHARBROILER AND ALLOW THE CHARBROILER TO COOL DONOTPUTMORETHAN5LBS LAVAROCK PER EACH BURNER ADJUSTING HEAT PATTERN It is possible through this arrangement to have a high heatorsearingsection whilehavingalowheatfinishing or holding s...

Page 6: ...7 ...

Page 7: ... 1 GUARD WELD ASSY 6036CBSB AGA 14 2F Z3035 1 2 3 BURNER 6015CBSB 6024CBSB 6036CBSB 15 2F Z3036 1 2 3 DEFLECTOR 6015CBSB 6024CBSB 6036CBSB 16 2C Z3154 1 2 3 BOLT 1 4 20 x 1 3 4 6015CBSB 6024CBSB 6036CBSB 17 2F Z3078 1 1 GRATE LAVA ROCK 15 6015CBSB 6036CBSB 18 2F Y7193 1 2 3 LAVA ROCK2 8 LB 6015CBSB 6024CBSB 6036CBSB 19 2F Z3077 2 2 2 GRATE LAVA ROCK 24 6024CBSB 6036CBSB 20 H3 Y8831 1 GRATE 3 6015C...