Star Manufacturing STAR-MAX 6015CBB-LP Installation And Operating Instructions Manual Download Page 6

PARTS LIST

EFFECTIVE

 IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED

            PAGE

          INCLUDE MODEL AND SERIAL NUMBER

OF

Some items are included for illustrative purposes only and in certain instances may not be available.

 

  

Number

Per

Unit

Description

  

   

Star Manufacturing International, Inc.

MODEL

Part

Number

  Key

  Number

   

 

12/21/01  Rev. -

6115RCBB, 6124RCBB, 6136RCBB, 6148RCBB Star-Max
Gas Radiant Charbroiler-15", 24", 36", 48"

1

2R-Z0934

1/2/3/4

KNOB-CONTROL

6115RCBB/6124RCBB/6136RCBB/6148RCBB

2

H3-Z3097

1

FRONT PANEL

6115RCBB

H3-Z3024

1

FRONT PANEL

6124RCBB

H3-Z3098

1

FRONT PANEL

6136RCBB

H3-Z3099

1

FRONT PANEL

6148RCBB

3

H3-T1026

1

GREASE DRAWER

6115RCBB

H3-Y7045

1/2

GREASE DRAWER

6124RCBB/6148RCBB

H3-Y7044

1

GREASE DRAWER

6136RCBB

4

G3-Y7047

2/2/2/4

SLIDE  DRAWER

6115RCBB/6124RCBB/6136RCBB/6148RCBB

5

2A-Z0314

4

LEG

6

2K-Z3017

1

INLET PIPE

7

H3-Z3082

2/2/2/4

DRAWER STOP

6115RCBB/6124RCBB/6136RCBB/6148RCBB

8

H3-Z3020

1

INLET PIPE SUPPORT

9

H3-Z4557

1

PRESSURE REGULATOR

1 0

2C-6517

1/2/3/4

NUT 1/4-20

6115RCBB/6124RCBB/6136RCBB/6148RCBB

1 1

2C-Y9714

2/4/6/8

WASHER 1/4

6115RCBB/6124RCBB/6136RCBB/6148RCBB

1 2

H3-Z3100

1

BRACKET BURNER REAR

6115RCBB

H3-Z3041

1

BRACKET BURNER REAR

6124RCBB

H3-Z3101

1

BRACKET BURNER REAR

6136RCBB

H3-Z3102

1

BRACKET BURNER REAR

6148RCBB

1 3

G3-624038

1

GUARD WELD ASSY

6115RCBB AGA

G3-624037

1

GUARD WELD ASSY

6124RCBB AGA

G3-624039

1

GUARD WELD ASSY

6136RCBB AGA

H3-648007

1

GUARD WELD ASSY

6148RCBB AGA

1 4

2F-Z3035

1/2/3/4

BURNER

6115RCBB/6124RCBB/6136RCBB/6148RCBB

1 5

2C-3155

1/2/3/4

BOLT 1/4-20 x 1 1/2

6115RCBB/6124RCBB/6136RCBB/6148RCBB

1 6

H3-Z3202

2/4/6/8

RADIANT

6115RCBB/6124RCBB/6136RCBB/6148RCBB

1 7

H3-Y8831

1

GRATE 3"

6115RCBB

1 8

2F-Y8830

2/4/6/8

GRATE 6"

6115RCBB/6124RCBB/6136RCBB/6148RCBB

1 9

H3-Z3040

1/2/3/4

BRACKET - BURNER FRONT

6115RCBB/6124RCBB/6136RCBB/6148RCBB

2 0

H3-624219

1/2/3/4

TUBE - PILOT ASSY

6115RCBB/6124RCBB/6136RCBB/6148RCBB

2 1

2P-1453

1

PLUG-PIPE

2 2

2V-6671

1/2/3/4

VALVE-PILOT

6115RCBB/6124RCBB/6136RCBB/6148RCBB

2 3

2A-Z3010

1/2/3/4

FITTING-ORIFICE

6115RCBB/6124RCBB/6136RCBB/6148RCBB

2 4

2J-Z3032

1/2/3/4

HOOD-BURNER #36

6115RCBB/6124RCBB/6136RCBB/6148RCBB

2 5

2J-Z3033

1/2/3/4

HOOD-BURNER #49

6115RCBB/6124RCBB/6136RCBB/6148RCBB

2 6

2V-Y8832

1/2/3/4

VALVE-BURNER

6115RCBB/6124RCBB/6136RCBB/6148RCBB

2 7

2M-Z3103

1

SIGN 15" CHARBROILER

6115RCBB

2M-Z3022

1

SIGN 24" CHARBROILER

6124RCBB

2M-Z3104

1

SIGN 36" CHARBROILER

6136RCBB

2M-Z3105

1

SIGN 48" CHARBROILER

6148RCBB

2 8

H3-Z3196

1/2/3/4

BRACKET-PILOT

6115RCBB/6124RCBB/6136RCBB/6148RCBB

1

1

Summary of Contents for STAR-MAX 6015CBB-LP

Page 1: ...g Instructions Instructions d installation etd opération STAR MAX GAS CHARBROILER MODELS 6015CBB LP 6024CBB LP 6036CBB LP 6048CBB LP 6115RCBB LP 6124RCBB LP 6136RCBB LP and 6148RCBB LP BARBECUE A GAZ STAR MAX MODELES 6015CBB LP 6024CBB LP 6036CBB LP 6048CBB LP 6115RCBB LP 6124RCBB LP 6136RCBB LP et 6148RCBB LP 2M Z5137 Rev 12 21 01 ...

Page 2: ...y piping system during any pressure testing of that system at test pressures in excess of 1 2 PSIG This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG For your protection we recommend a qualified install...

Page 3: ...he manifold and within six feet of the charbroiler CHECKING FOR GAS LEAKS Soap and water solution or other material acceptable for the purpose shall be used in locating gas leakage Matches candle flame or other sources of ignition shall not be used for this purpose Check entire piping system for leaks PILOTLIGHTINGINSTRUCTIONS The charbroiler is equipped with standing pilots and should be lit imme...

Page 4: ...oves to reposition CAUTION CHARBROILERS ARE HOT NEVER ATTEMPT TO CHANGE THE GRILL POSITION WHILE MEAT PRODUCTS ARE COOKING FLARE UPS CAN OCCUR UNEXPECTEDLY TURN OFF CHARBROILER AND ALLOW THE CHARBROILER TO COOL DO NOT PUT MORE THAN 5 LB LAVA ROCK PER EACH BURNER ADJUSTING HEAT PATTERN It is possible through this arrangement to have a high heat or searing section while having a low heat finishing o...

Page 5: ......

Page 6: ...3 Z3041 1 BRACKET BURNER REAR 6124RCBB H3 Z3101 1 BRACKET BURNER REAR 6136RCBB H3 Z3102 1 BRACKET BURNER REAR 6148RCBB 13 G3 624038 1 GUARD WELD ASSY 6115RCBB AGA G3 624037 1 GUARD WELD ASSY 6124RCBB AGA G3 624039 1 GUARD WELD ASSY 6136RCBB AGA H3 648007 1 GUARD WELD ASSY 6148RCBB AGA 14 2F Z3035 1 2 3 4 BURNER 6115RCBB 6124RCBB 6136RCBB 6148RCBB 15 2C 3155 1 2 3 4 BOLT 1 4 20 x 1 1 2 6115RCBB 612...

Reviews: