8 | TT46 User Manual
clockwise. This will retract the valve stem.
3. Screw the tester onto the breaker charging port. Twist the tester gauge
clockwise and read the pressure indicated on the gauge. Charge should
be 500-600 PSI (34-41 BAR).
Charge
4. Retract the tester valve stem.
5. Connect the charging assembly hose to the tester.
6. Twist the tester gauge clockwise to advance the valve stem.
7. Slowly open the snub valve and charge to 600-700 PSI (41-48 BAR).
8. Close the snub valve, retract the tester valve stem and remove the tester
from the breaker charging port. Replace the charging plug.
Tool Storage
Clean the tool and store in a clean, dry space that is safe from damage.
Ensure the tool is secured and will not move during transport. An unsecured
tool could cause injury or damage to the tool.
Tool Disposal
Hydraulic Oil
Hydraulic oil can contaminate the air, ground and water if not properly
recycled. Recycle hydraulic oil in accordance with all State, Federal and local
laws, at your local oil recycling facility.
Hydraulic Hoses
Hang hydraulic hoses to drain. Collect the oil for recycling. Contact your local
municipal recycling authorities for an approved hydraulic hose recycling site.
Tool Body
Drain hydraulic oil from the tool, making sure to collect the oil for recycling.
Discharge the accumulator, disassemble the tool and dispose of all non-metal
parts. Recycle the metal components. Contact your local municipal recycling
authorities for recycling instructions.
Accessories
4 inch steel with “V” cut (18 inch overall length)
44979
4 inch steel with “V” cut, Heavy Duty (18 inch overall length)
59034
4 inch steel with “V” cut (21 inch overall length)
44937
4 inch steel with “V” cut, Heavy Duty (21 inch overall length)
59033
4 inch steel (24 inch overall length)
33200
Anti-Vibration Handle Conversion Kit
27680
Service Tools
Tamping sleeve tool
01120
O-ring tool kit
04337
Seal kit
04595
Flow sleeve removal tube
04910
Flow sleeve removal tool
04919
Accumulator cylinder puller
05640
Accumulator tester
02835
Accumulator charge kit
31254
Charging assembly
15304
Flow and pressure tester
04182
Troubleshooting
Problem
Possible Cause
Solution
Tool does not run or
runs improperly.
The hydraulic power
source is not running
or not running
properly.
Ensure the power source
is delivering proper
flow and pressure. See
“Specifications” on
page 7. Proper flow
and pressure maintain
proper tool speed. Check
regularly.
Couplers or hoses are
blocked.
Turn off and disconnect
the tool from the
hydraulic power source.
Inspect and ensure no
blockage exists.
Low accumulator
charge pressure.
Check accumulator
charge. Recharge
if necessary. See
“Accumulator Charge -
Detail D” on page 7.
Hydraulic oil is above
the max. operating
temperature of 140°F
(60°C).
Provide an oil cooler
to maintain proper oil
temperature.
High Back Pressure.
Check the hydraulic
system for excessive
back pressure.
Mechanical failure.
Contact your STANLEY
dealer for service.