4.

 

The tag s details will be displayed in read-only mode. 

 

5.

 

TRANSMISSION SETTINGS, tap the Edit Configuration 

 icon on the Tag Details screen. 

6.

 

Edit the Tag Configuration accordingly. See BD (Bidirectional) 
Deployment Configuration
BD to UD, see  

7.

 

 

8.

 

UD (Unidirectional) Deployment Configuration. 

Summary of Contents for T15h

Page 1: ...T15h Temperature Humidity Tag Deployment User Guide 0981 697 000 REV A Published 2021 01 27 updated 2021 02 07...

Page 2: ...rietary to STANLEY Healthcare and is not to be distributed to any persons other than licensed AeroScout Visibility System users or other persons appointed in writing by STANLEY Healthcare Trademark Ac...

Page 3: ...Enabling BLE Tag Functions 15 Enabling Secured Tag Communication with MobileView 17 The STANLEY T15h Tag Certificate 18 Certificate Format 18 MobileView Server Certificates 18 MobileView Server Host N...

Page 4: ...ts 47 Temperature Event 47 Humidity Event 49 Battery Level Event 51 Out of Sight Event 51 External Power Event Optional 52 Sensor Tag Error Event 52 Mounting and Connecting 53 Connecting the Power Ada...

Page 5: ...nsor Detailed Report 67 Sensor Summary Report 71 Tag Models Accessories 74 Approved Barcode Readers 75 Tag Specifications 76 Environmental Specifications 76 Monitoring Temperature Humidity Ranges 76 T...

Page 6: ...T15h Tag Deployment User Guide 6 CE Conformance 79 Warranty 80...

Page 7: ...y Monitoring The tag is equipped with internal sensors that constantly monitor ambient temperature and humidity of mission critical locations such as operating rooms The T15h Tag can be supplied with...

Page 8: ...3 x and 14 x Supported Devices iPhone 5S and above iPad Pro Mini Air iPad 3rd generation and above iPod touch 5th generation and above Reference Documentation The following articles can be accessed by...

Page 9: ...s use BLE technology to communicate with the Deployment Manager DM app for device configuration and setup Beaconing and Bidirectional BD Communication The tags utilize lightweight beaconing communicat...

Page 10: ...dity readings Additionally temperature and humidity data is also sent to MobileView if the tag is configured to sync with MobileView Easy Battery Replacement The tag uses 2x 1 5V Alkaline AA batteries...

Page 11: ...T15h Tag Deployment User Guide 11 The following describes the parts of the T15h Tag Front View Back View Bottom View 1 2 3 4 5 6 8 9 7...

Page 12: ...g the T15h Tag 5 Mute Alarm Audit button 6 Sensor Air Vent 7 Battery Cover 8 USB C Screw Tightening Hole for securing the cable plug to the tag 9 Power USB C Connector Screen Values The No Description...

Page 13: ...tery Battery Level Medium Battery Low Depleted Battery Change battery immediately Power cable plugged in and supplying power to the tag Power cable disconnected Temperature and or Humidity out of rang...

Page 14: ...Select button Tag Menu Options Option Description Main Screen Displays the t BLE Activation Select this option to activate a BLE session with the Deployment Manager DM app The BLE will be active for...

Page 15: ...for the first time supplying power the warning icon will appear This indicates that the tag has not been configured yet Tag Configuration It is recommended to use the Deployment Manager DM Setup User...

Page 16: ...T15h Tag Deployment User Guide 16 3 Tap Product Key 4 Enter the Product Key PERF2197 5 Tap Add Key...

Page 17: ...secure BD Bidirectional tag sessions For more information on using MobileView in a secured mode refer the latest MobileView Deployment Guide Skip this section if the site is not using MobileView in a...

Page 18: ...e installed on the MobileView Server to allow the certificate validation to be performed by T15h Tags SSL Certificate issued for this specific server All Intermediate Certificates Root CA Certificate...

Page 19: ...hat sits between the SSL Certificate and the Root CA Certificate is called a chain or Intermediate Certificate The Intermediate Certificate is the signer issuer of the SSL Certificate The Root CA Cert...

Page 20: ...T15h Tag Deployment User Guide 20 Click on the Certification Path tab Double click on certification name Select the Details tab and then click on...

Page 21: ...T15h Tag Deployment User Guide 21 Click Next on the Welcome Page Select Base 64 encoded X 509 CER Click Next to Export the File will be cer...

Page 22: ...available on your mobile device either as an email attachment or in a file sharing application Refer to Enabling Secured Tag Communication with MobileView and Exporting a Secured Certificate from Mob...

Page 23: ...anager opens Tap Save 4 Tap OK 5 Configure the tag accordingly See Configuring Tags Loading from a File Sharing Application 1 Tap the required Certificate in your file sharing application for example...

Page 24: ...e configured at once 1 Ensure s BLE is activated which is indicated by the BLE icon BLE is activated when the tag is powered on for the first time If ress the Select button on the tag to access the me...

Page 25: ...T15h Tag Deployment User Guide 25 5 Tap to select the required T15h Tag s and then tap Configuration Up to 50 tags can be configured at once...

Page 26: ...ure humidity data to MobileView Tags transmit and receive values and configuration data from MobileView via a Bidirectional session automatically every 24 hours providing there are no network issues D...

Page 27: ...e defined configurations One ID must be selected You can view more details about each ID by tapping on the information icon ID Description ID 191 1min Beacon transmission and logging interval to 1min...

Page 28: ...e to sound unless muted on the tag itself Min Max Temperature Thresholds Set the minimum and maximum temperature threshold values The tag s Local Alarm will be triggered when a value is out of its con...

Page 29: ...value is out of its configured range Alarm Delay Period Select must be out of a configured range before an alarm is triggered For example if the alarm delay period is set to 5 minutes and the lue is...

Page 30: ...ust be selected You can view more details about each ID by tapping on the information icon The following table explains each Configuration ID ID Description ID 191 1min Beacon 1 transmission and loggi...

Page 31: ...s the tag an IP address every time the tag is associated with the network OR Static IP the IP address and connection settings are specified manually Note The Static IP setting is not available if more...

Page 32: ...d a secure Certificate from MobileView To load a secured Certificate refer to the Enabling Secured Tag Communication with MobileView section Any loaded secured Certificate from MobileView is displayed...

Page 33: ...Information message appears if no HTTPS certificate is loaded WI FI 1 must be added a Tap Add Wi Fi Network b SSID c Select the Authentication method WPA2 PSK or 802 1X PEAP MSCHAPv2 d For WPA2 PSK e...

Page 34: ...s option on will delete any certificate currently stored on the tag after the tag configuration has been applied in step 7 below 7 Apply the tag configuration by tapping the check icon 8 Tap Apply to...

Page 35: ...tions Configurations are saved to your DM app 1 From either the Tag Configuration Tag Settings or Wireless Settings screens tap 2 Select Save Configuration 3 Enter a name for the file 4 Tap Save File...

Page 36: ...n list Select ll open allowing you to save the file Google Drive App Tap the 3 dots menu in the file row and select file Dropbox App Gmail App Tap the file attachment in the email and then tap the sha...

Page 37: ...T15h Tag Deployment User Guide 37 You can view following 1 2 Detect the tag 3 Tap the information icon of the tag to view 4 The tag s details will be displayed in read only mode...

Page 38: ...Note Only one tag can be edited at a time If you need to edit multiple tags edit one tag save the configuration and then load the new configuration to the other tags See Saving Exporting Importing and...

Page 39: ...ap the Edit Configuration icon on the Tag Details screen 6 Edit the tag onfiguration accordingly See 7 8 UD Unidirectional Deployment Configuration If you are changing the BD Bidirectional Deployment...

Page 40: ...ues are out of range By default toggling the button Note The buzzer will continue to sound unless muted on the tag itself Min Max Temperature Thresholds Set the minimum and maximum temperature thresho...

Page 41: ...5 minutes and the lue is out of its configured range the alarm will only be triggered if its value does not normalize within the set time of 5 minutes Note The tag will immediately move out of alarm...

Page 42: ...be displayed in read only mode 5 TRANSMISSION SETTINGS tap the Edit Configuration icon on the Tag Details screen 6 Edit the Tag Configuration accordingly See BD Bidirectional Deployment Configuration...

Page 43: ...Edit Configuration icon 11 wireless settings accordingly See the BD Bidirectional Deployment Configuration section 12 To Save Load or Export a configuration tap the Options icon 13 Tap the Apply icon...

Page 44: ...smission of secure messages with a unique key that is assigned to the tag Secured tag messages are then decrypted and validated by the Engine before being sent to MobileView For configuration procedur...

Page 45: ...d events If the tag is setup for BD MobileView will transmit data such as temperature and humidity threshold values to the tag and receive data from the tag Alerts will be triggered according to confi...

Page 46: ...eaches 13 2 below the max threshold of 15 Trigger alert after e out of a configured range before an Alert is sent For example if the time an alert will be triggered if its value does not normalize wit...

Page 47: ...following Events should be used for the T15h Tag Event Name Description Temperature Triggers alerts when the temperature values are out of a configured range Humidity Triggers alerts when the humidit...

Page 48: ...igger time Only Trigger after a configured range before an Alert is sent For example if the time its configured range an alert will be triggered if its value does not normalize within the set time of...

Page 49: ...ues an alert based on humidity readings transmitted by active tags equipped with a humidity sensor You can set specific conditions for the alert or inherit the asset category thresholds and set the de...

Page 50: ...ple if the time configured range an alert will be triggered if its value does not normalize within the set time of 15 min Asset default time Select this option to use the value defined on the Asset Ca...

Page 51: ...le if you select Medium the alert will be issued when the battery power level falls below Medium Actions Set the actions accordingly Out of Sight Event This event will trigger an alert if the tag fail...

Page 52: ...s disconnected for Specify the time that should elapse after the external power is disconnected before an alert is triggered Actions Set the actions accordingly Sensor Tag Error Event preventing data...

Page 53: ...e power outlet first and then to the T15h Tag C port NOTE The AC DC adaptor must be safety approved according to IEC EN UL 60950 1 with a rated voltage of 5Vdc and rated current up to 3A maximum The T...

Page 54: ...than 2 meters from the ground The tag comes with a mounting cradle and double sided tape for easy mounting Additionally Velcro and screws can be used not supplied Mounting with Double Sided Tape Plac...

Page 55: ...T15h Tag Deployment User Guide 55 Placing the Tag in the Cradle Place the tag at an angle into the mounting cradle and make sure it clicks in place Removing the Tag from the Cradle Click...

Page 56: ...ns Changing the Temperature Conversion The tag can display the temperature in either Celsius or Fahrenheit To change the temperature conversion press the button under the conversion icon Muting an Ala...

Page 57: ...the Select button to access the menu 2 Show Hide Thresholds using the arrow buttons 3 Press the Select button Changing the Display Language but supports 5 additional languages French Swedish Finnish S...

Page 58: ...Audit report has been recorded successfully The operation is also logged by the tag and is sent to MobileView along with the current temperature and humidity and the Minimum and Maximum Temperature a...

Page 59: ...ime Typically a sync with MobileView is automatically performed every 24 hours If changes to the configuration of the tag have been made in MobileView you can perform an immediate sync from the tag by...

Page 60: ...h BD configured tags When a warning is triggered the warning icon is shown on 1 To view the Warnings press the Select button to access the menu 2 option using the arrow buttons 3 Press the Select butt...

Page 61: ...r TC service is running Wrong root CA Certificate Verify the is correct and valid Consult your local IT department Tag Controller connection timeout The Tag Controller may be busy and can t send a new...

Page 62: ...re Selection tab Select the required firmware for the T15h Tag Click Save Tag firmware will be updated during the next BD session You can initiate an immediate sync by following the steps in the Perfo...

Page 63: ...ks Red Alert Dismiss Long beep LED 2 LED stops blinking External Power Connection Short beep LED 1 LED turns on Blue External Power Disconnection Long beep LED 1 LED turns off Muting Buzzer Short beep...

Page 64: ...eries Disconnected Yes Battery Only Tag battery full Battery Only Tag battery medium Battery Only Tag battery low Replacing the Batteries The tag is supplied with 2x 1 5V Alkaline AA batteries Replace...

Page 65: ...ing Reports tab For more information refer to the MobileView Environmental Monitoring User Guide for 5 5 and above Battery Level Report the Battery PWR column shows if the tag is being powered by an e...

Page 66: ...ata Offline data BD deployments only is data that was not uploaded to MobileView in real time due to network failures and was uploaded during a BD session or a manual sync Offline data is indicated wi...

Page 67: ...roup of assets The report shows detailed data for each asset separately Additionally the report supports Offline data Offline data BD deployments only is data that was not uploaded to MobileView in re...

Page 68: ...us by using the Event Status option Uncheck Include Events to exclude the Events from the report The following Event details are displayed in the report All Events related to the Asset s Current Senso...

Page 69: ...lude Readings to exclude the Readings from the report Include Graphs Note Graphs are only available when using PDF format Note Not available for Contact Sensors By default the report will include Grap...

Page 70: ...clude all Manual Audits performed during the selected period Uncheck Include Manual Audit VFC to exclude the Manual Audits from the report The following details are displayed in the report Current tem...

Page 71: ...ortation MKT for a substance can be defined as the calculated value derived from the complete recording over a specified period of time If this value is within the permitted min max values the substan...

Page 72: ...ch tag sensor 1 graph for temperature and 1 graph for humidity Reporting Intervals can be either on a Daily basis min and max values on a daily basis during the defined period or Period min and max va...

Page 73: ...T15h Tag Deployment User Guide 73...

Page 74: ...ssories SKU T15h Tag TAG 1500 H T15h Tag with NIST Certification TAG 1500 H NIST External Power for T15h Tag NA Outlet ADP 1500 U External Power for T15h Tag Europe Outlet ADP 1500 E External Power fo...

Page 75: ...T15h Tag Deployment User Guide 75 The following barcode readers have been tested with the T15h Tags Honeywell Xenon XP 1950HD Zebra Symbol DS4308...

Page 76: ...ore up to 128 000 readings Physical and Mechanical Dimensions LWH 114 x 77 x 20 3mm 4 4 x 3 X 0 8inch Weight 150g 5 3oz with batteries Connectors 1 x USB C connector Electrical Battery 2 x 1 5V Alkali...

Page 77: ...liant Wi Fi Security Modes WPA2 PSK AES 802 1x Enterprise security PEAP MSCHAPv2 Logging Rates 1 minutes 5 minutes and 15 minutes Certification Radio EMC FCC Part 15 Subpart C Subpart B RSS 247 ICES 0...

Page 78: ...his device may not cause harmful interference and 2 this device must accept any interference received including any interference that may cause undesired operation Changes or modifications not express...

Page 79: ...RoHS RoHS Directive 2011 65 EU CE Conformance IEC 60950 1 2005 IEC 60950 1 2005 AMD1 2009 IEC 60950 1 2005 AMD2 2013 IEC 62368 1 2014 EN 301 489 1 V2 2 0 EN 301 498 17 V3 2 0 EN 300 328 V2 1 16...

Page 80: ...iginal Hardware components STANLEY s obligations hereunder are conditioned upon the return of affected Hardware in accordance with STANLEY s then current Return Material Authorization RMA procedures N...

Page 81: ...s rendering of technical advice facilities or service in connection with Customer s purchase of the STANLEY Healthcare AeroScout Products Except for the foregoing warranties which shall be the exclusi...

Page 82: ...a part of Stanley Black stanleyhealthcare com STANLEY Healthcare 75 Portsmouth Blvd Suite 220 Portsmouth NH 03801 Tel 1 888 622 6992 North America E mail stanleyhealthcare sbdinc com Asia Pacific E m...

Reviews: