© 2016, Obelis S.A Registered Address:
Bd.Général Wahis, 53
1030 Brussels, Belgium
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO A POWER
SOURCE
Problem
Possible Cause
Solution
Burner does not light
1. Air in gas line
2. Gas pressure from cylinder
too low
3. LP cylinder valve turned off
4. Obstruction in air
passageway
5. Dirt in pilot orifice
6. Safety switch in cylinder
valve engaged
1. Keep depressing the valve knob for at
least 30 seconds to remove any air in
line.
2. Check LP cylinder pressure. Tank may
be empty
3. Open LP cylinder valve
4. Inspect and clean heater housing
5. Blow out, or otherwise clean the pilot
orifice
6. Close LP cylinder valve. Wait one
minute for switch to click off. Reopen LP
cylinder valve slowly
No spark is created
when ignited
1. Electrode damaged or
broken
2. Loose or disconnected
igniter wire
3. Broken igniter wire
1. Replace the electrode
2. Tighten or reconnect loose wire
3. Replace igniter wire
Heater stops running
by itself
1. Thermocouple damaged
2. Gas control valve damaged
3. Gas leak
4. Thermocouple not in
contact with pilot flame
5. Out of fuel
1. Replace thermocouple
2. Replace gas control valve
3. Check all connections for leaks and repair
4. Clean inside of heater housing
5. Replace LP cylinder
Troubleshooting
7
STANLEY, The STANLEY Logo, The Notched Rectangle and the Yellow and Black Diagonal Package
Design are all trademarks of Stanley Black & Decker, Inc. or an affiliate thereof.
Summary of Contents for ST-14A-CH-E
Page 61: ...ST 14A CH E ST 14S CH E 500250500 13 B 0845 16 PIN 0845CR 0037 19 3...
Page 62: ...30 60 200 RU 1...
Page 63: ...1 RU 2...
Page 64: ...RU 3...
Page 66: ...2009 142 EN 449 2007 15 1 5 2 9 4 2 30 5 61 193 1 2 3 4 5 6 7 8 9 5...
Page 67: ...1 2 4 5 6 6...
Page 72: ......