Stanley SPL31A User Manual Download Page 10

10 ► SPL31 

User Manual

CHECK HYDRAULIC POWER

SOURCE

1. 

Using a calibrated flowmeter and pressure gauge, 

check that the hydraulic power source develops a 

flow of 5-10.5 GPM/15-40 LPM at 2000 psi/140 bar.

2. 

Make certain the hydraulic power source is equipped 

with a relief valve set to a max of 2500 psi/172 bar.

3. 

Check that the hydraulic circuit matches the tool for 

open center (OC) operation.

CHECK TOOL

1. 

Make sure all tool accessories are correctly installed. 

Failure to install tool accessories properly can result 

in damage to the tool or personal injury.

2. 

There should be no signs of leaks.

3. 

The  tool  should  be  clean,  with  all  fittings  and 

fasteners tight.

CHECK TRIGGER MECHANISM

1. 

Check that the trigger operates smoothly and is free 

to travel between the "ON" and "OFF" positions.

CONNECT HOSES

1. 

Wipe  all  hose  couplers  with  a  clean  lint-free  cloth 

before making connections.

2. 

Connect  the  hoses  from  the  hydraulic  power 

source to the hose couplers on the Spike Puller. It 

is a good practice to connect the return hose first 

and disconnect it last to minimize or avoid trapped 

pressure within the system.

3. 

Observe flow indicators stamped on hose couplers 

to be sure that oil will flow in the proper direction. 

The female coupler is the inlet coupler.

NOTE:  The  pressure  increase  in  uncoupled  hoses 

left in the sun may result in making them difficult to 

connect.  When  possible,  connect  the  free  ends  of 

operating hoses together.

OPERATING PROCEDURES

1.  Observe all safety precautions.
2.  Move the hydraulic circuit control valve to the ON 

position.

3. 

Place  the  spike  puller  firmly  over  the  spike  to  be 

pulled  making  sure  the  end  of  the  chute  is  in  full 

contact with the spike plate.

SPL31A

1.  The SPL31A has an automatic pull cycle that 

engages the spike and sets the tool to the rail at a 

slow speed; then fully removes the spike at a higher 

speed, the cycle is automatic, and operates by fully 

depressing the trigger. 

2. 

At the top of the stroke release the trigger and the 

spike will automatically be ejected from the puller.

COLD WEATHER OPERATION

If  the  spike  puller  is  to  be  used  during  cold  weather, 

preheat  the  hydraulic  fluid  at  low  engine  speed. 

When  using  the  normally  recommended  fluids,  fluid 

temperature should be at or above 50° F/ 10° C (400 

ssu/82 centistokes) before use.

OPERATION

Summary of Contents for SPL31A

Page 1: ...2013 Stanley Black Decker Inc New Britain CT 06053 U S A 72926 12 2018 Ver 12 USER MANUAL Safety Operation and Maintenance SPL31A SPL31A N SPL31A S HYDRAULIC SPIKE PULLER...

Page 2: ...2 SPL31 User Manual NOTES...

Page 3: ...outine maintenance must be performed by an authorized and certified dealer Please read the following warning To fill out a product warranty validation form and for information on your warranty visit w...

Page 4: ...messages that follow this symbol to avoid possible injury or death This safety alert and signal word indicates an imminently hazardous situation which if not avoided will result in death or serious in...

Page 5: ...The operator must be familiar with all prohibited work areas such as excessive slopes and dangerous terrain conditions Do not over reach Maintain proper footing and balance at all times Do not inspect...

Page 6: ...THE TOOL BEFORE PRESSURING SYSTEM SYSTEM PRESSURE HOSE MUST ALWAYS BE CON NECTED TO TOOL IN PORT SYSTEM RETURN HOSE MUST ALWAYS BE CONNECTED TO TOOL OUT PORT REVERSING CONNECTIONS MAY CAUSE REVERSE T...

Page 7: ...OTH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUMALLOWABLE CURRENT LEAKAGE INACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS SEE OTHER SIDE SIDE 2 D O N O T R E M O V E T H I S T A G 3 DO NOT E...

Page 8: ...Pressure 2500 175 1 25 4 Return 2500 175 13 16 49 60 up to 25 up to 8 5 8 16 Pressure 2500 175 3 4 19 Return 2500 175 13 16 49 60 26 100 8 30 3 4 19 Pressure 2500 175 1 25 4 Return 2500 175 Figure 1...

Page 9: ...operator discomfort at the tool Filter minimum full flow filtration 25 microns 25 microns 25 microns 25 microns Sized for flow of at least For cold temp startup and maximum dirt holding capacity 30 G...

Page 10: ...it last to minimize or avoid trapped pressure within the system 3 Observe flow indicators stamped on hose couplers to be sure that oil will flow in the proper direction The female coupler is the inlet...

Page 11: ...ormance develop the following chart can be used as a guide to correct the problem When diagnosing faults in operation of the spike puller always check that the hydraulic power source is supplying the...

Page 12: ...E O Ring Couplers HTMA EHTMA Flush Face Type Male and Female Connect Size and Type 3 8 Male Pipe Adapter Weight without hose whips couplers with oil 31 lb 14 0 kg Overall Length 32 75 inches 83 1 cm O...

Page 13: ...9 35404 1 COMPRESSION COIL SPRING 10 35421 1 COMPRESSION COIL SPRING 11 72888 1 RELIEVING VALVE SPOOL 12 72890 1 RELIEF POPPET 13 73043 1 SPIKE PULLER HANDLE WITH EXPANDER PLUGS INSTALLED 14 73021 1...

Page 14: ...8 9 10 11 18 19 20 22 23 24 27 28 29 30 31 32 33 34 36 37 38 39 40 43 44 45 46 24 46 4 10 55 49 50 56 FOR PARTS TO HANDLE ASSEMBLY SEE PAGE 13 SEE PAGE 6 FOR DECAL P N s PISTON PISTON ROD SPL31A SPL31...

Page 15: ...CASTING 27 56725 2 HOSE ASSY SPL31A and SPL31A S ONLY 66727 2 HOSE ASSY SPL31A N ONLY 28 71942 1 CHECK VALVE 29 72537 1 SPL31 AUX HANDLE 30 72538 1 PISTON INSERT 31 72540 4 CAPSCREW 32 73044 1 CHUTE...

Page 16: ...Stanley Infrastructure 3810 SE Naef Road Milwaukie Oregon 97267 5698 USA 503 659 5660 Fax 503 652 1780 www stanleyinfrastructure com...

Reviews: