14
Fig.13
C
D
If the appliance recess is close to any combustible
material, it must be adequately protected using a
suitable insulation material (See table 1) and config-
ured as showing in Fig. 14.
MATERIAL DESCRIPTION
SIL C A 2 5 0 KM
Approval in Germany
National technical approval no Z-43.14-117 valid for
fireplace and tiled stove construction
Approval in Switzerland
Fire Prevention Approval no. 15202
Fire resistance DIN EN 13501-2
El 120 (8O mm)
CE-Certificate
0432-CPD-420002242/2-6
Construction material class DIN 4102
Non-combustible A1
Bulk density (± 10 %) DIN EN 1094-4
250 kg/m3
Porosity DIN EN 1094-4
Approx. 90 %
Compressive strength DIN EN 1094-5
> 1.4 MPa
Thermal conductivity at 200 °C DIN EN 993-14
<0.1 W/mK
Thermal expansion at 500 °C DIN EN 993-8
< 0.2 %
Standard dimensions in mm
3,000 x 1,250, 1,250 x 1,000; 1,250 x 500; 1,000 x
625; 625 x 500
Standard thicknesses in mm
30-100