Stanley IW24 Safety, Operation & Maintenance Download Page 7

IW24 User Manual | 7

• 

Use PPE that conforms to standards ANSI Z87.1 (Eye and Face 
Protection), ANSI Z89.1 (Head Protection), ANSI Z41.1 (Foot Protection) 
and ANSI S12.6 (S3.19) (Hearing Protection).

• 

Do not wear loose fitting clothing, jewelry or gloves with cut or frayed 
fingers when operating the tool. Entanglement, choking, scalping and 
laceration can occur if loose clothing, personal jewelry, neck wear, hair 
or gloves are not kept away from the rotating tool and it’s accessories. 
Gloves can become entangled with the rotation drive, causing severed 
or broken fingers.

M003

Wear Ear 

Protection

M004

Wear Eye 

Protection

M016

Wear a Mask

Sound

• 

Exposure to high noise levels can cause permanent, disabling hearing 
loss and other problems, such as tinnitus (ringing, buzzing, whistling 
or humming in the ears). Use hearing protection in accordance with 
employer’s instructions and as required by occupational health and 
safety regulations. Appropriate controls to reduce the risk can include 
actions such as damping materials to prevent work pieces from 
“ringing”.

• 

Use and maintain as recommended in the manual to prevent an 
unnecessary increase in noise levels. 

Vibration

• 

When using a rotary or percussive tool to perform work related 
activities, the operator can experience discomfort in the hands, arms, 
shoulders, neck or other parts of the body.

• 

If you experience numbness, tingling, pain or whitening of the skin 
in your fingers or hands, stop using the tool. Tell your employer and 
consult a physician. 

• 

Wear warm clothing when working in cold conditions and keep your 
hands warm and dry.

• 

Exposure to vibration can cause disabling damage to the nerves and 
blood supply of the hands and arms.

• 

Do not use worn or ill-fitting sockets or extensions, as this is likely to 
cause a substantial increase in vibration.

• 

Do not touch sockets or accessories during impacting. This increases the 
risk of cuts, burns or vibration injuries.

• 

Use and maintain as recommended in the manual to prevent an 
unnecessary increase in vibration. 

• 

Check the vibration level after each service. If higher than normal, 
contact your STANLEY dealer.

Hydraulic

• 

Warning: 

Hydraulic fluid under pressure could cause skin injection 

injury. Do not check for leaks with your hands. If you are injured by 
hydraulic fluid, get medical attention immediately.

• 

Do not let hydraulic oil get on the skin. Hydraulic oil is hot. Wear 
Personal Protection Equipment (PPE) at all times.

• 

If exposed to hydraulic fluid, wash hands immediately.

• 

Do not exceed the maximum relief valve setting stated on the tool.

• 

Inspect and clean couplers before use, daily. Replace damaged couplers 
immediately.

• 

Hydraulic circuit control valve must be OFF before coupling or 
uncoupling tools. Failure to do so may damage the couplers and cause 
overheating of the hydraulic system.

• 

Ensure the couplers are properly connected and are tight.

• 

Do not operate the tool at fluid temperatures above 140°F (60°C). 
Higher temperatures can cause operator discomfort and damage to the 
tool.

• 

Do not exceed the rated flow and pressure as stated on the tool. Rapid 
failure of the internal seals may result.

Summary of Contents for IW24

Page 1: ...ts Num ro de s rie de l quipement Numero de serie del equipo Matricola dell attrezzatura ALL MODELS NOTED ABOVE Has been manufactured in conformity with Wurde hergestellt in bereinstimmung mit Est fa...

Page 2: ...2 IW24 User Manual 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 A 1 2 B C D...

Page 3: ...IW24 User Manual 3 4 5 8 9 11 E 1 2 3 4 5 6 7 8 10 9 11 12 13 14 16 15 17 18 19 20 21 F...

Page 4: ...4 IW24 User Manual 1 2 3 4 5 6 7 8 9 10 11 12 13 11 13 10 14 15 16 H 1 2 3 4 5 6 7 8 I 15 16 1 2 3 4 5 7 8 9 10 11 12 13 14 18 17 19 20 21 22 G 6...

Page 5: ...ing Ring 2 08125 Seal Backup Washer 3 08180 Backup Ring 4 04888 O ring 5 01364 O ring 6 30136 Rotation Direction Decal 7 09698 Motor Housing includes 08123 07995 03252 8 09702 Main Shaft 9 00255 O rin...

Page 6: ...an be a tripping hazard Operator must start in a work area without bystanders and must assess the risk to bystanders including the risk of serious injury or death caused by the tool or accessories dro...

Page 7: ...ll your employer and consult a physician Wear warm clothing when working in cold conditions and keep your hands warm and dry Exposure to vibration can cause disabling damage to the nerves and blood su...

Page 8: ...Decal Non CE Models 4 Tool Name Tag 5 Main Handle 6 Female Coupler 7 Electrical Danger Decal 8 General Caution Decal 9 Assist Handle 10 Trigger 11 CE Decal 12 Impact Mechanism 13 Circuit Type E Decal...

Page 9: ...he hammer case and inspect the impact mechanism If the mechanism is not well lubricated or if the grease is burned see Grease the Impact Mechanism on page 9 4 Inspect tool to ensure all decals are leg...

Page 10: ...our STANLEY dealer for service Tool runs too fast Hydraulic power source is not running properly Ensure the power source is delivering proper flow and pressure See Specifications on page 8 Proper flow...

Page 11: ......

Page 12: ...STANLEY Infrastructure 6430 SE Lake Road Portland Oregon 97222 USA 503 659 5660 Fax 503 652 1780 www stanleyinfrastructure com...

Reviews: