LIGHTING

1. 

Before lighting the stove, ensure that any build up of ashes in the 

fire box has been removed and that the ashpan has been emptied.

2. 

Open the firebox and cover the grate with crumpled pieces of paper.

3. 

Lay pieces of kindling on top of the paper towards the back of the 

fire box.

4. 

Open the primary air inlet by turning the control knob to setting 4.

5. 

Open the secondary air control by sliding the control lever located

over the top of the fire door to the right. (See Fig.8).

6. 

Ignite the paper and close the firedoor.

7. 

When the kindling is well alight, open the fire door and add more

kindling of a larger size to sustain the fire. Close the firedoor. Do 

not operate this appliance with the firedoor open.

8. 

Never use inflammable liquid i.e. gasoline, petrol paraffin etc. to 

start or freshen up a fire in this heater.

9. 

When a hot bed of fuel is established, add the normal fuel load and

adjust the air controls to the required setting.

10.  When re-fuelling open the firedoor and reload, close the firedoor.

11.  To shut the fire down, do not add fuel, make sure that the firedoor 

is properly closed and that the primary and secondary air controls

are all in the closed position. Cutting off the air supply will reduce

the heat output.

This appliance is hot whilst in operation.

Keep children, clothing and furniture a safe distance away.

8

Summary of Contents for GRAINNE

Page 1: ...s appliance is hot while in operation and retains its heat for a long period of time after use Children aged or infirm persons should be supervised at all times and should not be allowed to touch the...

Page 2: ...12 Floor Protection 4 13 T echnical Data 4 14 Specification 5 15 Operating Instructions 6 16 Low Slumber Burn 6 17 Primary Air Control 6 18 Recommended Fuels 6 19 Important Notes 7 20 Lighting 8 21 D...

Page 3: ...when the length of the horizontal section should not exceed 150mm In order to minimise flue resistance and to make sweeping easier it is recommended to use 2 x 45 o bends rather than a 90 o bend The...

Page 4: ...requirement for this appliance use the following equation a total free area of at least 550mm 2 per kW of rated output above 5kW shall be provided If there is another air using appliance fitted in the...

Page 5: ...It is recommended that this appliance is sited next to and on a non combustible surface A minimum all round clearance of 100 mm will allow air circulation and not impede the performance of the stove F...

Page 6: ...en up a fire in this heater Keep all such liquid well away from the heater at all times Operate stove only with fuelling door and ashpit doors closed This heater is hot whilst in operation Keep childr...

Page 7: ...at all times Operate the stove only with the fuelling door closed except for re fuelling Fig 8 OPEN When burning coal timber or peat CLOSE When burning anthracite and smokeless fuels WARNING DO NOT OB...

Page 8: ...pen for long periods as this will over heat the unit causing unnecessary damage Close the ash door between removing and replacing the ashpan 9 Clean the chimney at least twice a year 10 Burning soft f...

Page 9: ...the fire door and add more kindling of a larger size to sustain the fire Close the firedoor Do not operate this appliance with the firedoor open 8 Never use inflammable liquid i e gasoline petrol para...

Page 10: ...e hob before relight ing the fire TO REPLACE DAMAGED GRATE OR GRATE BAR Remove the front brick the back brick all the left hand side bricks and both small right side bricks from the stove taking care...

Page 11: ...n be carefully used on the vitreous enamel 3 Use only products recommended by the Vitreous Enamel Association these products carry the Vitramel label 4 DO NOT USE ABRASIVE PADS OR OVEN CLEANSERS CONTA...

Page 12: ...rmostat 23 Front Brick 24 Back Brick 25 Side Back Brick 26 Left Front Brick 27 Right Front Brick 28 Side Brick No 1 29 Side Brick No 2 30 LH Front Brick No 2 31 LH Fire Door 32 RH Fire Door 33 Ash Pit...

Reviews: