background image

10

ENGLISH

(Original instructions)

To reduce the risk of injury, only STANLEY FATMAX 

recommended accessories should be used with this product.

Maintenance

Your tool has been designed to operate over a long period of 

time with a minimum of maintenance. Continuous satisfactory 

operation depends upon proper tool care and regular cleaning.

Warning!

 Before performing any maintenance, switch off and 

unplug the tool.

u

 

Regularly clean the ventilation slots in your tool using a 

soft brush or dry cloth.

u

 

Regularly clean the motor housing using a damp cloth. Do 

not use any abrasive or solvent-based cleaner.

Protecting the environment

Z

Separate collection. Products and batteries marked 

with this symbol must not be disposed of with 

normal household waste.

Products and batteries contain materials that can be 

recovered or recycled reducing the demand for raw materials.

Please recycle electrical products and batteries according to 

local provisions.  

Further information is available at

www.2helpU.com

Technical data

SFMCW221

 

Input voltage

V

dc

18

Oscillations (no load)

min

-1

9000 - 12000

Orbits (no load)

min

-1

9000 - 12000

Sanding base surface

mm

2

8972

Weight

kg

0.93

Charger

SFMCB11

SFMCB12

SFMCB14

Input Voltage

V

AC

230

230

230

Output Voltage

V

DC

18

18

18

Current

A

1.25

2

4

Battery

SFMCB201

SFMCB202

SFMCB204 SFMCB206

Voltage

V

DC

18

18

18

18

Capacity

Ah

1.5

2.0

4.0

6.0

Type

Li-Ion

Li-Ion

Li-Ion

Li-Ion

Level of sound pressure according to EN62841:

Sound pressure (L

pA

) 74.5 dB(A), Uncertainty (K) 3 dB(A)

Sound power (L

WA

)

 

85.5 dB(A), Uncertainty (K) 3 dB(A)

Vibration total values (triax vector sum) according to EN62841:

Sanding (a

h

) 7.8 m/s

2

, uncertainty (K) 1.5 m/s

2

Declaration of Conformity

 

The Supply of Machinery (Safety) Regulations 2008

SFMCW221 Detail sander

STANLEY FATMAX declares that these products described 

under "technical data" are in compliance with:

Equipment Regulations 2012, S.I. 2012/3032 (as amended).

EN62841-1:2015; EN62841-2-4:2014.

These products conform to the following UK Regulations:

The Supply of Machinery (Safety) Regulations, 2008, S.I. 

2008/1597 (as amended).

Electromagnetic Compatibility Regulations, 2016, 

S.I.2016/1091 (as amended).

The Restriction of the Use of Certain Hazardous Substances 

in Electrical and Electronic

For more information, please contact Stanley at the following 

address or refer to the back of the manual.

The undersigned is responsible for compilation of the techni-

cal file and makes this declaration on behalf of STANLEY 

FATMAX

Karl Evans

Vice President Professional Power Tools EANZ 

STANLEY FATMAX, 270 Bath Road, Slough,

Berkshire, SL1 4DX

United Kingdom 

31/08/2021

EC declaration of conformity

MACHINERY DIRECTIVE

%

SFMCW221 Detail sander

STANLEY FATMAX declares that these products described 

under "technical data" are in compliance with:

2006/42/EC, EN62841-1:2015; EN62841-2-4:2014.

These products also comply with Directive 2014/30/EU and 

2011/65/EU. For more information, please contact STANLEY 

FATMAX at the following address or refer to the back of 

the manual.

Summary of Contents for FATMAX SFMCW221D1

Page 1: ...www stanley eu SFMCW221 7 2 1 3 11 6 4 8 5 10 9 ...

Page 2: ...2 English original instructions 4 ...

Page 3: ...3 9 5 11 9 10 6 12 12b 12a A 6a 6 B 6 7 6 C D E F ...

Page 4: ...re and or serious injury Save all warnings and instructions for future reference The term power tool in the warnings refers to your mains operated corded power tool or battery operated cordless power tool 1 Work area safety a Keep work area clean and well lit Cluttered or dark areas invite accidents b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids ...

Page 5: ...e charger specified by the manufacturer A charger that is suitable for one type of battery pack may create a risk of fire when used with another battery pack Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock b Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators Th...

Page 6: ...arning Contact with or inhalation of dust arising from sanding applications may endanger the health of theoperator and possible bystanders Wear a dust mask specifically designed for protection against dust and fumes and ensure that persons within or entering the work area are also protected u Thoroughly remove all dust after sanding u Take special care when sanding paint which is possibly lead bas...

Page 7: ...ore use Do not attempt to charge damaged batteries Electrical safety Your charger is double insulated therefore no earth wire is required Always check that the mains voltage corresponds to the voltage on the rating plate Never attempt to replace the charger unit with a regular mains plug u If the supply cord is damaged it must be replaced by the manufacturer or an authorised STANLEY FATMAX Service...

Page 8: ...Fig B The battery includes a state of charge indicator to quickly determine the extent of battery life as shown in figure B By pressing the state of charge button 6a you can easily view the charge remaining in the battery as illustrated in figure B Installing and Removing the Battery Pack from the tool Warning Make certain the lock off button is engaged to prevent switch actuation before removing ...

Page 9: ...NG DRINKING or SMOKING should be done in the work area to prevent ingesting contaminated paint particles Workers should wash and clean up BEFORE eating drinking or smoking Articles of food drink or smoking should not be left in the work area where dust would settle on them Environmental safety u Paint should be removed in such a manner as to minimize the amount of dust generated u Areas where pain...

Page 10: ... Li Ion Level of sound pressure according to EN62841 Sound pressure LpA 74 5 dB A Uncertainty K 3 dB A Sound power LWA 85 5 dB A Uncertainty K 3 dB A Vibration total values triax vector sum according to EN62841 Sanding ah 7 8 m s2 uncertainty K 1 5 m s2 Declaration of Conformity The Supply of Machinery Safety Regulations 2008 SFMCW221 Detail sander STANLEY FATMAX declares that these products descr...

Page 11: ...arantee is valid within the territories of the Member States of the European Union and the European Free Trade Area To claim on the guarantee the claim must be in accordance with STANLEY FATMAX Terms and Conditions and you will need to submit proof of purchase to the seller or an authorised repair agent Terms and conditions of the STANLEY FATMAX 1 year guarantee and the location of your nearest au...

Page 12: ...NA007058 REV 0 11 2021 United Kingdom STANLEY FATMAX Tel 01753 511234 270 Bath Road Fax 01753 572112 Slough Berkshire SL1 4DX www stanleytools co uk ...

Reviews: