Stanley A6BB304SCR512 Instruction Manual Download Page 8

8

the cord grip and that the wires are not trapped when 

replacing the plug cover. The mains lead on this product 

is fitted with a 13 amp (BS1363/A) plug. A 13 amp 

(BS1362) fuse must be fitted in the plug.

If in doubt consult a qualified electrician

There are no user serviceable parts inside this product 

except those referred to in the manual. Always refer 

servicing to qualified service personnel. Never remove 

any part of the casing unless qualified to do so; this unit 

contains dangerous voltages.

  Warning! 

For your protection if this product is to be used outdoors 

it should not be exposed to rain or used in damp 

locations. Do not place the product on damp surfaces, 

use a workbench if available. For added protection use 

a suitable residual current device (R.C.D.) at the socket 

outlet.

Note: 

If the mains cable requires replacing it must be 

replaced with an identical one and fitted by a 

qualified person.

5.3  On/Off switch (ref. 8)

To switch on the equipment set the On/Off switch (ref. 

8) to position 

I

.

Move the On/Off switch (ref. 8) to position 

O

 to switch 

off the equipment.

5.4  Adjusting the pressure

●  You can adjust the pressure on the pressure gauge 

(ref. 6) using the pressure regulator (ref. 7).

●  The set pressure can be taken from the quick-lock 

coupling (ref. 5).

5.5  Setting the pressure switch

The pressure switch is set at the factory.

Switch-on pressure 6 bar

Switch-off pressure 8 bar

6.  CLEANING AND MAINTENANCE

  

Warning! 

Pull the power plug before doing any cleaning and 

maintenance work on the appliance.

  

Warning! 

Wait until the compressor has completely cooled 

down. Risk of burns!

  

Warning! 

Always depressurize the tank before carrying out 

any cleaning and maintenance work.

6.1  Cleaning

●  Keep the safety devices free of dirt and dust as far 

as possible. Wipe the equipment with a clean cloth or 

blow it with compressed air at low pressure.

●  We  recommend  that  you  clean  the  appliance 

immediately after you use it.

●  Clean  the  appliance  regularly  with  a  damp  cloth 

and some soft soap. Do not use cleaning agents 

or solvents; these may be aggressive to the plastic 

parts in the appliance. Ensure that no water can get 

into the interior of the appliance.

●  You must disconnect the hose and any spraying tools 

from the compressor before cleaning. Do not clean 

the compressor with water, solvents or the like.

6.2  Condensation water

The condensation water must be drained off each day 

by opening the drain valve (ref. 11) (on the bottom of the 

pressure vessel).

  

Warning! 

The condensation water from the pressure vessel 

will contain residual oil. Dispose of the condensation 

water in an environmentally compatible manner at 

the appropriate collection point.

6.3  Safety valve (ref. 10)

The safety valve has been set for the highest permitted 

pressure of the pressure vessel. It is prohibited to adjust 

MAINTENANCE RESUMPTIVE TABLE

FUNCTION

AFTER THE FIRST 100 

HOURS

EVERY 100 HOURS

Cleaning of intake filter and/or 

substitution of filtering element

Draining tank condensate

Periodically and at the end of work

Summary of Contents for A6BB304SCR512

Page 1: ...Oilless Compressor Air compressor Instruction manual for owner s use Original instructions GB A6BB304SCR512 D 200 8 6 UK Support Number 0870 1 630 630...

Page 2: ...Stanley is a registered trademark of The Stanley Works GB Preserve this handbook for future reference...

Page 3: ...GB KEY TO PRODUCT SAFETY SIGNS Before use read the handbook carefully Warning hot surfaces Dangerous voltage Danger automatic control closed loop Hearing sight and respiratory protection must be worn...

Page 4: ...4 HP kW l l min cfm volt Hz A min 1 bar psi kg lbs 1 5 1 1 6 180 6 35 220 240 50 5 5 3400 8 116 9 19 8 1 1 9 4 2 11 10 5 7 6 12...

Page 5: ...5 2 7 5 12 4 8 6 3 13 15 4 15 14 4 Brown Live L or Red Blue Neutral N or Black...

Page 6: ...n and animals at a distance from the work area This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowl...

Page 7: ...rohibited to use the compressor in areas where work is conducted with sprayed water 5 ASSEMBLY AND STARTING Warning You must fully assemble the appliance before using it for the first time 5 1 Fitting...

Page 8: ...NING AND MAINTENANCE Warning Pull the power plug before doing any cleaning and maintenance work on the appliance Warning Wait until the compressor has completely cooled down Risk of burns Warning Alwa...

Page 9: ...on correctly Unscrew the hexagonal head of the check valve clean the valve seat and the special rubber disk replace if worn Reassemble and tighten carefully Reduction of performance Frequent start up...

Page 10: ...10 memo...

Page 11: ...l Livello di potenza acustica garantito dB A Guaranteed sound power level dB A Robassomero 14 07 2014 Conforme d lgs N 262 02 La conformit all allegato VI proc 1 della direttiva 2000 14 CE stata contr...

Page 12: ...MI MEGFELEL AZ AL BBI RENDELETEKNEK JE V SOULADU S N SLEDUJ C MI SM RNICEMI JE V S LADE S NASLEDOVN MI SMERNICAMI ER I OVERENSSTEMMELSE MED F LGENDE BESTEMMELSER ZLEYEN KURALLARA UYGUNLU UNU BEYAN EDE...

Reviews: