Caution, risk of electric shock
The light source and control gear contained in this luminaire shall only be replaced by the
manufacturer or his service agent or a similar qualified person.
No. D00189637B
Bolt
Safety bolt
Part name
Screw for cover glass
※ Do not loosen
Body
Bolt
Terminal block
Top cover
Cable ground
Spring
Safety bolt
Because it will cause falling of Luminaire, please process according the following;
Apply hole processing of Φ15 mm to the pole adapter.
Check the pole adapter
43.5
Φ15
For safety bolt
Pole adapter
Luminaire
1. Loosen the two M8 bolts for fixing and safety bolt.
Insert the luminaire into the pole adapter and then tighten the bolts.
Tightening torque: 12.5 N · m
Installation of luminaire
2/5