Stanley Electric LLF0017A/LEN1/104/E/IN/A Instruction Manual Download Page 2

 

     

Caution, risk of electric shock   

The light source  and control gear contained in this luminaire shall only be replaced by the 
manufacturer or his service agent or a similar qualified person.

 

No. D00189637B 

Bolt 

Safety bolt 

Part name 

Screw for cover glass 
※ Do not loosen 

Body 

Bolt 

Terminal block 

Top cover 

Cable ground 

Spring 

Safety bolt 

Because it will cause falling of Luminaire, please process according the following; 
Apply hole processing of Φ15 mm to the pole adapter. 

Check the pole adapter 

43.5 

Φ15 
For safety bolt  

Pole adapter 

Luminaire 

1. Loosen the two M8 bolts for fixing and safety bolt. 
    Insert the luminaire into the pole adapter and then tighten the bolts. 

    Tightening torque: 12.5 N · m 
 

Installation of luminaire 

2/5 