5. INSTALLATIONS TIPS
5.0 How can I disconnect the cables from the FF525 in case I need to do so
for the installation?
·
Open the FF525 box by unscrewing the four screws (see Figure on Par. 2.3.1).
·
Once the screws are removed, pull out the panel and the Printed Circuit Board (PCB).
Unscrew the cables from the PCB.
·
Wire the cables as needed.
·
Reconnect the cables to the PCB.
·
Push the panel towards the case (be sure to have well positioned the rubber gasket).
Close the FF525 box by screwing the four screws.
5.1 LED Status Indicator
The FF525 has a small LED that blinks. There are seven different LED behaviours,
representing seven different diagnostic conditions described below.
·
OFF
: DC power is not being supplied to the
FF525.
·
ON CONTINUOUSLY
: The transducer is not connected to the
Chart Plotter and problem with cable of the
transducer cable.
·
1 LONG FLASH EVERY 2 SECONDS
: The FF525 is not connected with the Chart
Plotter. Black Box is working properly, but
it is not connected to the Chart Plotter.
Configure the I/O Port.
·
2 SHORT FLASHES EVERY 2 SECONDS : The FF525 is connected to the Chart
Plotter and is operating correctly.
·
3 SHORT FLASHES EVERY 2 SECONDS : A not-STANDARD HORIZON transducer
(without transducer ID) has been connected
·
4 SHORT FLASHES EVERY 2 SECONDS : No transducer connected.