1.5 GASES AND FUMES

PLEASE NOTE! GAS MAY BE LETHAL OR DANGEROUS TO HUMAN HEALTH!

• 

Always stay clear of the gas exhaust.

• 

Ensure proper ventilation of the work space and avoid gas inhalation.

• 

Chemical substances (lubricants, solvents) must be removed from the surfaces of welded details as they 

burn and emit toxic smokes under the influence of temperature.

• 

Welding galvanised details is permitted only when efficient ventilation is provided with filtration and 

access to fresh air. Zinc fumes are highly toxic, an intoxication symptom is so-called metal fever.

2. TECHNICAL  DETAILS

Product name

Welding machine

Model

S-MIGMA-195 UK

Voltage / frequency

230 V~ / 50Hz

Rated input current

16 A (MMA)

14 A (MIG)

No-load voltage

22-39 V

Welding current (MMA/MIG)

70-195 A

Duty cycle (MMA/MIG)

15 %

Welding current at 100% duty cycle (MMA/MIG)

75 A

Wire diameter

0,6 – 0,8 mm

Wire type

Full / core (FLUX)

3. CONNECTION OF THE DEVICE

3.1 GENERAL NOTES

• 

The device must be used according to its purpose, with observance of OHS regulations and restrictions 
resulting from data included in the rating plate (IP level, operation cycle, supply voltage, etc.).

• 

The machine must not be opened as it will cause warranty loss and, in addition, exploding, unshielded 

elements can cause serious injuries.

• 

The producer does not bear any responsibility for technical changes in the device or material losses 

caused by the introduction of the said changes.

• 

In case of incorrect device operation, contact the service centre.

• 

Louvers must not be shielded - the welder must be positioned at 30 cm distance from objects 
surrounding it.

• 

The welder must not be kept under your arm or near to your body.

• 

The machine must not be installed in rooms with aggressive environments, high dustiness and near 

devices with high electromagnetic field emission.

 

3.2 DEVICE STORAGE

• 

The machine must be protected against water and moisture.

• 

The welder must not be positioned on heated surfaces.

• 

The device must be stored in a dry and clean room.

3.3 CONNECTING THE DEVICE
3.3.1 CONNECTING THE POWER

• 

Connection of the device must be performed by a qualified person. In addition, a person with required 

qualifications should check if the earthing or electrical installation with protection system is in line with 

the safety regulations and if they operate correctly.

• 

The device must be placed near the work station.

• 

Connection of excessively long conduits to the machine must be avoided.

• 

One-phase welders should be connected to a socket fitted with an earthing prong.

• 

Welders powered from a 3-Phase network are delivered without a plug, the plug must be obtained 

independently and installation should be assigned to a qualified person.

PLEASE NOTE! THE DEVICE MAY ONLY BE USED UPON CONNECTION TO AN INSTALLMENT WITH 
A PROPERLY FUNCTIONING FUSE

3.3.2 CONNECTING GAS

• 

Gas tanks must be placed far from the welded object and be protected against falling.

• 

Gas connector of the welder must be connected with the tank or gas installation by means of the 
correct pipe and regulator with gas flow regulation. Please note! Connection of line regulators to the 

tank and the other way round is prohibited. Such a change can result in regulator damage and serious 

injuries.

• 

Economical gas use extends the welding time

4. OPERATION

EN

S-MIGMA-195 UK

1

2

3

5

7

6

8

9

10

1.

Power cord

2.

Wire feed rate adjustment knob

3.

On/off switch

4.

Welding current adjustment switch

5.

Operation mode switch MIG / MMA

6.

MIG cable

Summary of Contents for S-MIGMA-195

Page 1: ...S MIGMA 195 UK USER MANUAL INSTRUKCJA OBSŁUGI MANUEL D UTILISATION ISTRUZIONI D USO MANUAL DE INSTRUCCIONES BEDIENUNGSANLEITUNG e x p o n d o c o m ...

Page 2: ...ropane butane lighters or matches Use facial protection helmet or shield and eye protection with a filter featuring a shade level matching the sight of the welder and the welding current The safety standards suggest colouring No 9 minimum No 8 for each current below 300 A A lower colouring of the shield can be used if the arc is covered by the workpiece Always use approved safety glasses with side...

Page 3: ...not be kept under your arm or near to your body The machine must not be installed in rooms with aggressive environments high dustiness and near devices with high electromagnetic field emission 3 2 DEVICE STORAGE The machine must be protected against water and moisture The welder must not be positioned on heated surfaces The device must be stored in a dry and clean room 3 3 CONNECTING THE DEVICE 3 ...

Page 4: ...ment too tightly as it might negatively impact the welding effectiveness of the device Please keep the end of the wire straight and free of burrs EN 5 Open the rotary knob 6 Raise the pressure element 7 Check that the grooves on the wire feed roll match the wire diameter 8 Now lower the pressure element and tighten the knob until the wire runs evenly on the rolls If the wire slips on the rolls tig...

Page 5: ...et an denen Altgeräte aus privaten Haushalten ihres Gebietes für Sie kostenfrei entgegengenommen werden Möglicherweise holen die rechtlichen Entsorgungsträger die Altgeräte auch bei den privaten Haushalten ab Bitte informieren Sie sich über Ihren lokalen Abfallkalender oder bei Ihrer Stadt oder Gemeindeverwaltung über die in Ihrem Gebiet zur Verfügung stehenden Möglichkeiten der Rückgabe oder Samm...

Reviews: