Maximum voltage between    : CAT 

  600V 

terminals and earth ground 

Fuse protection             : F 200mA/250V 

Power                     : 9v battery NEDA 1604 or 6F22 

Display                    : LCD ,1999 counts, updates 2.3/sec 

Measuring method          : Dual-slope integration A/D converter 

Overage indication        : Only figure “1” on the display 

Polarity indication           :

.”displayed for negative polarity 

Operating a Environment    : 0 to 40 

°

Storage temperature        :-10

°

C to 50

°

Low battery indication     :

      ”appears on the display 

Size                     : 138mm * 69mm * 31mm 

Weight           Approx.170g 

 

DC VOLTAGE 

Range 

Resolution 

Accuracy 

200mV 

100  

μ

±

  0.5% of rdg   

±

  2 digits 

2V 

1mV 

±

  0.5% of rdg 

±

    2 digits 

20V 

10mV 

±

  0.5% of rdg 

±

    2 digits 

200V 

100mV 

±

  0.5% of rdg 

±

    2 digits 

600V 

1V 

±

  0.5% of rdg 

±

    2 digits 

Overload Protection 250V rms, For 200mV range and 600V dc or rms, ac for other ranges 

DC CURRENT 

Range 

Resolution 

Accuracy 

200 A 

0.1

μ

±

  1% of rdg 

±

    2 digits 

2mA 

1

μ

±

  1% of rdg 

±

    2 digits 

20mA 

10 

μ

±

  1% of rdg 

±

    2 digits 

200mA 

100 

μ

±

  1.5% of rdg 

±

    2 digits 

10A 

10mA 

±

  3% of rdg 

±

    2 digits 

Overload Protection: F 200Ma/250V fuse (10A range unfused) 

AC VOLTAGE 

Range 

Resoltion 

Accuracy 

200V 

100mV 

±

1.2% of rdg   

±

10 digits 

600V 

1V 

±

1.2% of rdg 

±

  10 digits 

Overload Profection: 600V dc or rms, ac for all ranges 

Frequency range:40Hz to 400Hz,Response:Average responding, calibrated in rms. of a sine wave 

DIODE & CONTINUITY 

Range    Description 

            If continuity exists (about less than 1.5k

Ω

  ) 

            built-in buzzer will sound 

           

Show the approx. forward voltage drop of the diode 

 

Overload Protection: 250V dc or rms.ac. 

 

 

 

-

 

 

 

 

 

Summary of Contents for XL830L

Page 1: ...Digital multi meter multi tester INSTRUCTION MANUAL ...

Page 2: ...astened completely Do not use abrasives or solvents on the meter To clean use a damp cloth and mild detergent only DURING USE Never exceed the protection limit values indicated in specifications for each range of measurement When the meter is linked to measurement circuit do not touch unused terminals Never use the meter to measure voltages that might exceed 600V above earth ground in category Ⅱ i...

Page 3: ...t reading and H symbol will appear on the LCD until pushing it again Rotary switch This switch is used to select functions and desired ranges as well as to turn on off the meter COM jack Plug in connector for black negative test lead 10A jack Plug in connector for red test lead for 10A measurement V Ω mA jack Plug in connector for red positive test lead for voltage resistance and current except 10...

Page 4: ...V 100mV 0 5 of rdg 2 digits 600V 1V 0 5 of rdg 2 digits Overload Protection 250V rms For 200mV range and 600V dc or rms ac for other ranges DC CURRENT Range Resolution Accuracy 200 A 0 1μA 1 of rdg 2 digits 2mA 1μA 1 of rdg 2 digits 20mA 10 μA 1 of rdg 2 digits 200mA 100 μA 1 5 of rdg 2 digits 10A 10mA 3 of rdg 2 digits Overload Protection F 200Ma 250V fuse 10A range unfused AC VOLTAGE Range Resol...

Page 5: ...0mA and 10A remove red lead to 10A jack 2 Set the rotary switch at desired DCA position 3 Open the circuit in which the current is to be measured and connect test leads in series with the circuit 4 Read current value on LCD display along with the polarity of red lead connection AC VOLTAGE MEASUREMENT 1 Connect the red test lead to the V Ω mA jack and the back test lead to COM jack 2 Set the rotary...

Page 6: ...rement with the thermoelectric couple carefully 4 Read the temperature C on the display TEST SIGNAL USE 1 Range switch to position 2 A test signal 50Hz or 1000Hz depending on the model of mulita meter appears between V Ω mA and COM jack The output voltage is approx 5Vpp with a certain DC component so additional insulating capacitor should be used BATTERY FUSE REPLACEMENT If appears on display it i...