GENERAL
Maximum voltage between : CAT
Ⅱ
600V
terminals and earth ground
Fuse protection : F 200mA/250V
Power : 9v battery NEDA 1604 or 6F22
Display : LCD ,1999 counts, updates 2.3/sec
Measuring method : Dual-slope integration A/D converter
Overage indication : Only figure “1” on the display
Polarity indication :
“
.”displayed for negative polarity
Operating a Environment : 0 to 40
°
C
Storage temperature :-10
°
C to 50
°
C
Low battery indication :
“
”appears on the display
Size : 138mm * 69mm * 31mm
Weight Approx.170g
DC VOLTAGE
Range
Resolution
Accuracy
200mV
100
μ
V
±
0.5% of rdg
±
2 digits
2V
1mV
±
0.5% of rdg
±
2 digits
20V
10mV
±
0.5% of rdg
±
2 digits
200V
100mV
±
0.5% of rdg
±
2 digits
600V
1V
±
0.5% of rdg
±
2 digits
Overload Protection 250V rms, For 200mV range and 600V dc or rms, ac for other ranges
DC CURRENT
Range
Resolution
Accuracy
200 A
0.1
μ
A
±
1% of rdg
±
2 digits
2mA
1
μ
A
±
1% of rdg
±
2 digits
20mA
10
μ
A
±
1% of rdg
±
2 digits
200mA
100
μ
A
±
1.5% of rdg
±
2 digits
10A
10mA
±
3% of rdg
±
2 digits
Overload Protection: F 200Ma/250V fuse (10A range unfused)
AC VOLTAGE
Range
Resoltion
Accuracy
200V
100mV
±
1.2% of rdg
±
10 digits
600V
1V
±
1.2% of rdg
±
10 digits
Overload Profection: 600V dc or rms, ac for all ranges
Frequency range:40Hz to 400Hz,Response:Average responding, calibrated in rms. of a sine wave
DIODE & CONTINUITY
Range Description
If continuity exists (about less than 1.5k
Ω
)
built-in buzzer will sound
Show the approx. forward voltage drop of the diode