10 Rotary control INTERVAL
This control lets you adjust the time interval between two haze outputs in a range of 10 to 200 seconds.
11 Rotary control VOLUME
With this control you can set the amount of haze per output to be produced (between 0 % and 100 %).
12 The green status LED indicates that the unit has reached the required operating temperature for haze generation.
13 Button MANUAL
Press this button to output the maximum amount of haze regardless of the other settings.
14 The red LED indicates that the device is heating up.
15 Button CONT
Press this button to turn continuous operation on or off. In this mode, that amount of haze is continuously output
which you have set with the VOLUME control.
16 The yellow LED indicates that the Timer function is active.
17 Button TIMER
Use this switch to turn the Timer function on or off. In this mode, the amount of haze set by the VOLUME control is
output within the time intervals that you have set with the INTERVAL control.
Connections and operating elements