Installation and operating manual 

TEF2882 

 

Navigation Light 

 

Compliance/Conformity 

 

 

-

 

IEC 60945 Cl. 4.5.3 “Compass safe distance” waived according to EN 14744 Cl. 4.8.8 “No 

magnetic materials” 

 

 

 

-

 

IEC 60945 Cl. 8.8 “Rain and spray” omitted according to EN 14744 Cl. 5.3.6 “Covered by IP67” 

 

 

-

 

EN  60529:2013 – IP66/67

 

 

 

-

 

MEDB000038Y (K2W) 

 

-

 

MEDD000019S (K2W) 

 

 

 

Summary of Contents for TEF 2882

Page 1: ...Installation and operating manual TEF2882 Navigation Light Navigation Light TEF 2882 Document properties TUM7225 Revision Comment Revision date Approved 0 First issue 21 01 2022 CS ...

Page 2: ...rties TUM7225 1 Warnings and risk levels 3 General information 3 Marking and intended use 4 Technical data 4 Product description 4 Transport and storage 4 Mounting and installation 5 Mounting 5 Positioning of lights 6 Electrical connections 6 Options and spare parts 8 Disposal 8 Compliance Conformity 9 Appendix 1 10 ...

Page 3: ...malfunctions etc General information Before installation make sure to read and understand this installation and operating manual Observe national assembly and installation regulations Always contact the manufacturer if anything is unclear or if you notice any faults on the product or in this document This installation and operating manual shall be available to anyone operating installing inspectin...

Page 4: ... 66 67 Dimensions Simplex models 140 x 140 x 139 mm Excluding cable entry Duplex models 140 x 140 x 139 mm Excluding cable entry Net weight Simplex model max 1 66 kg Duplex model max 1 75 kg Product description No maintenance is obtained through a simplified plug and play modular design for ease of installation and unmatched availability self monitoring capabilities Application Observe national an...

Page 5: ...nt malfunction In turn this can lead to severe damage and or injuries Mounting See figure 1 2 Fixing The navigation light shall be fixed to a plane horizontal surface by 4x M8 bolts Maximum torque 8 Nm Ref figure 2 figure 3 Cable entries Direction of cable entries see figure 1 Ensure enough space to route cable and terminate cable properly Minimum space requirement Cables bending radius 50 mm Figu...

Page 6: ...aps mounted on lights connector sockets are not IP rated and will not protect against water intrusion Cable termination Cable diameter Ø9 16 mm Part 2882xxx delivered as standard with terminal nut for Ø9 16 mm cable Wire cross section 1 0 mm2 to 2 5 mm2 Wire diameter incl insulation 2 0 mm to 3 80mm Connections 1 Strip approx 60 mm off the cable 2 Loop the PE conductor around the live conductors 1...

Page 7: ...her the socket wrench a wrench or a plier Screw the terminal nut as far as it will go or with the specified torque It must not be possible to unscrew the terminal nut again by hand 8 Seal off any non allocated connections using a protective cap Terminal 1 24V 2 3 N 0V PE Protective earth Note In order to obtain proper EMI PE wire should always be terminated ...

Page 8: ...ather plug M12 IP68 50091434 Blind plug M25 50091436 Standoff feet M8 set of 4 pcs 7247 Mounting adapter to 155 x 155 mm M10 hole pattern 6694 Disposal CAUTION This equipment or part of this equipment is considered EE Waste and shall be handled accordingly Observe national and local regulations and statutory regulations regarding disposal Separate materials when sending it for recycling Ensure env...

Page 9: ...ompliance Conformity IEC 60945 Cl 4 5 3 Compass safe distance waived according to EN 14744 Cl 4 8 8 No magnetic materials IEC 60945 Cl 8 8 Rain and spray omitted according to EN 14744 Cl 5 3 6 Covered by IP67 EN 60529 2013 IP66 67 MEDB000038Y K2W MEDD000019S K2W ...

Page 10: ...Installation and operating manual TEF2882 Navigation Light Appendix 1 ...