background image

254914 / 640160300040

2017-12-01·BA00·III·en·02

Mounting and installation

21

Linear Luminaire for Fluorescent Lamps

Series EXLUX 6401

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN

7.3.4 Address module settings

NOTICE

Before operating an emergency lighting central battery system, the luminaire addressing 

is to be performed by means of a screwdriver for slotted screws 4 mm.

12 Logic switch

0 V

negative logic

230 V

positive logic

13 Address switch

Slide 

switch

0 / 10

Rotary switch

0 / F

Luminaire 

address

0

0

0 (invalid)

0

1

1

0

2

2

...

...

...

0

9

9

0

A

10

10

0

10

10

1

11

...

...

...

10

9

19

10

A

20

10

B ... F

invalid

L‘

N

Steuereingang

control input

0V

230V

ON

10

0

+

address

12

13

Ätna Zone II

PPW EX 34../..

Summary of Contents for PRACHT EXLUX 6401 Series

Page 1: ...UX 6401 Alfred Pracht Lichttechnik GmbH Pracht Leuchten Gmbh Am Seerain 3 35232 Dautphetal Buchenau Germany Tel 49 6466 9140 0 Fax 49 6466 9140 444 info pracht com www pracht com TNA ZONE II PPW EX 34...

Page 2: ...Aufbewahrung der Betriebsanleitung 5 3 2 Sichere Verwendung 5 3 3 Bestimmungsgem e Verwendung 5 3 4 Umbauten und nderungen 5 4 Funktion und Ger teaufbau 6 4 1 Funktion 6 4 2 Ger teaufbau 6 5 Technisch...

Page 3: ...Zertifikate und EU Konformit tserkl rung www stahl ex com Das Ger t verf gt ber eine IECEx Zulassung Siehe IECEx Homepage http iecex iec ch 2 Erl uterung der Symbole 2 1 Symbole in der Betriebsanleitu...

Page 4: ...Gefahr des Schadens 2 3 Symbole am Ger t GEFAHR Gefahren f r Personen Nichtbeachtung der Anweisung f hrt zu schweren oder t dlichen Verletzungen bei Personen WARNUNG Gefahren f r Personen Nichtbeachtu...

Page 5: ...die durch fehlerhaften oder unzul ssigen Einsatz sowie durch Nichtbeachtung dieser Betriebsanleitung entstehen besteht keine Haftung Vor Installation und Inbetriebnahme sicherstellen dass das Ger t un...

Page 6: ...n zur Leuchtensteuerung und berwachung in Verwendung mit einer Zentralbatterieanlage von R STAHL optional 4 2 Ger teaufbau GEFAHR Explosionsgefahr durch zweckentfremdete Verwendung Nichtbeachten f hrt...

Page 7: ...ern zusammen Eins befindet sich auf dem Leuchtengeh use 1 und ein zweites auf der Montageplatte 2 Beide sind von au en sichtbar Typschild 1 6001 5 1 2 5 1 1 1 Typschild 2 6001 5 2 2 9 2 Leuchtentyp 60...

Page 8: ...ch im Betrieb 198 264 V AC 198 253 V AC ADR 176 264 V DC 198 264 V AC 198 253 V AC ADR 176 264 V DC Spannung DC im Z ndfall 196 264 V DC 196 264 V DC Frequenz 0 50 60 Hz 0 50 60 Hz Lampenbetrieb DC 2...

Page 9: ...ich Leuchten ohne Adressbaustein Leuchten mit Adressbaustein Technische Daten 18 W 60081 IEC 2220 G13 36 W 60081 IEC 2420 G13 58 W 60081 IEC 2520 G13 Kaltstartgeeignete Lampen verwendenb Typ Ta min in...

Page 10: ...ndardleuchte Kunststoff 2 x M25 x 1 5 Kabeleinf hrung 8161 und 2 x M25 x 1 5 Verschlussstopfen 8290 beiliegend Metall 2 x Metallplatte M20 x 1 5 mit PE verbunden f r Leitungseinf hrungen aus Metall Ac...

Page 11: ...Adressen pro Stromkreis ber Kodierschalter einstellbar Die Schaltungsart Dauerlicht Bereitschaftslicht oder geschaltetes Licht der Leuchte ist frei programmierbar Mischbetrieb innerhalb eines Kreises...

Page 12: ...t beeintr chtigt wird z B Druckbedingungen chemische mechanische thermische elektrische Einfl sse sowie Schwingungen Feuchte Korrosion siehe IEC EN 60079 14 Ger t nur durch geschultes und mit den eins...

Page 13: ...ich die Montagelage mit Zentralverschluss nach oben vermeiden Die Montagelage mit Lichtaustritt nach oben ist im Au enbereich untersagt F r den Einsatz im Au enbereich empfehlen wir den Einbau eines K...

Page 14: ...00 15447E00 Montageb gel Deckenschiene Seitliche Montagetaschen f r variable Aufh ngepunkte Bei der Montage der Leuchte mit den Deckenschienen auf plane Unterlage achten Ansonsten kann das Geh use ver...

Page 15: ...bei Rohrschellenmontage die L sung der R STAHL Schaltger te GmbH mit integrierter Montageschiene und damit verbundenen sicheren und stabilen Vierpunktbefestigung Bei Rohrschellen Punktbefestigung bern...

Page 16: ...ngfeldleuchten EXLUX erleichert die Montage und die Installation bei der Aneinanderreihung der Leuchten Das Schienenprofil kann auch zugleich als Kabelkanal verwendet werden Zur Anpassung der Leuchten...

Page 17: ...or Verschmutzung Beachten Ausf hrung ohne Schalter Leuchte spannungsfrei schalten und vor Wiedereinschalten sichern Ausf hrung mit Schalter Durch das Bet tigen des Zentralverschlusses wird die Leuchte...

Page 18: ...geklemmt werden Rein Raus Verdrahtung Beachten Die Klemmung exakt durchf hren Keine Isolierung des Leiters unterklemmen Die Leiter nicht vertauschen Die Regeln der Technik bei Anschluss des Leiters be...

Page 19: ...und 6 mm2 eindr htig Abisolierl nge 10 11 mm Abisolierl nge 10 11 mm 15516E00 15438E00 Leuchte mit Adressbaustein K figzugfederklemmen Klemmbereich 0 75 4 mm2 eindr htig feindr htig 2 freie Klemmstel...

Page 20: ...ur Leuchte werkseitig verdrahtet L N Steuereingang Anschluss L werkseitig verdrahtet zum Klemmstein D1 N werkseitig verdrahtet zum Klemmstein D2 geschaltetes Licht positive Logik zum Einschalten der L...

Page 21: ...INWEIS Vor Betrieb an einer Notlicht Zentralbatterie Anlage ist die Leuchtenadressierung mit einem Schlitzschraubendreher 4 mm vorzunehmen 12 Logik Schalter 0 V negative Logik 230 V positive Logik 13...

Page 22: ...nicht von der R STAHL Schaltger te GmbH Beachten Sie die geforderte Staubdichtheit die geforderte Z ndschutzart die erforderliche Temperaturbest ndigkeit die IP Schutzart gem Typschild die Betriebsan...

Page 23: ...digt ist sich keine Fremdk rper im Ger t befinden das Ger t vorschriftsm ig verschlossen ist 9 Betrieb 9 1 Fehlerbeseitigung Wenn sich der Fehler mit den genannten Vorgehensweisen nicht beheben l sst...

Page 24: ...und entsprechend geschulter Elektro Fachkraft ausf hren lassen Die geltenden nationalen Bestimmungen im Einsatzland beachten Pr fen Ma nahmen der zul ssigen Umgebungstemperatur Bei ber oder Unterschre...

Page 25: ...sockel m ssen unbesch digt sein Auf Sitz der Lampe achten nach dem Drehen ist der Lampensitz verriegelt Lampen rechtzeitig tauschen 06058E00 Leuchte ffnen Wanne um 180 nach hinten schwenken Wanne durc...

Page 26: ...n und ausf llen Ger t zusammen mit dem Serviceschein wieder in der Originalverpackung an die R STAHL Schaltger te GmbH senden 11 Entsorgung Nationale und lokal g ltige Vorschriften und gesetzliche Bes...

Page 27: ...g marquage 2 D Extb IIICT 80 C Db CCoi58 EU Baumusterpr fbescheinigung PTB 14 ATEX 2016 EU Type Examination Certificate Physikalisch Technische Bundesanstalt Attestation d examen UE de type Bundesalle...

Page 28: ...uage II3G Ex ec IIC T4 Gc II3G Ex db ec IIC T4 Gc II3G Ex ec nC IIC T4 Gc C II 3G Ex db ec nC IIC T4 Gc II 3D Ex tc NIC T80 C De Konformit tsaussage PTB14 ATEX 2017 Conformity Statement Physikalisch T...

Page 29: ...EXLUX 6401 Alfred Pracht Lichttechnik GmbH Pracht Leuchten Gmbh Am Seerain 3 35232 Dautphetal Buchenau Germany Tel 49 6466 9140 0 Fax 49 6466 9140 444 info pracht com www pracht com TNA ZONE II PPW E...

Page 30: ...evice 4 3 Safety notes 5 3 1 Operating instructions storage 5 3 2 Safe use 5 3 3 Intended Use 5 3 4 Modifications and alterations 5 4 Function and device design 6 4 1 Function 6 4 2 Device design 6 5...

Page 31: ...See certificates and EU Declaration of Conformity www stahl ex com The device has IECEx approval See IECEx homepage http iecex iec ch 2 Explanation of the symbols 2 1 Symbols in these operating instru...

Page 32: ...g countermeasures to avoid the danger damage 2 3 Symbols on the device DANGER Danger to persons Non compliance with the instruction results in severe or fatal injuries to persons WARNING Danger to per...

Page 33: ...with its intended and approved purpose only We cannot be held liable for damage caused by incorrect or unauthorized use or by non compliance with these operating instructions Before installation and...

Page 34: ...ess module for luminaire control and monitoring for use with a central battery unit from R STAHL optional 4 2 Device design DANGER Explosion hazard due to improper use Non compliance results in severe...

Page 35: ...ed intwo One is on the enclosure 1 and another onthe mounting plate 2 Both are visible fromoutside Type label 1 6001 5 1 2 5 1 1 1 Type label 2 6001 5 2 2 9 2 Type of lumi naire 6001 5 2 2 9 5 1 2 2 5...

Page 36: ...operation 198 264 V AC 198 253 V AC ADR 176 264 V DC 198 264 V AC 198 253 V AC ADR 176 264 V DC DC voltage in case of ignition 196 264 V DC 196 264 V DC Frequency 0 50 60 Hz 0 50 60 Hz Lamp operation...

Page 37: ...Luminaires without address module Luminaires with address module Technical Data 18 W 60081 IEC 2220 G13 36 W 60081 IEC 2420 G13 58 W 60081 IEC 2520 G13 Please use cold start lamps Type Ta min at C Ta...

Page 38: ...ction Technical Data Standard luminaire Plastic 2 x M25 x 1 5 cable gland 8161 and 2 x M25 x 1 5 stopping plugs 8290 enclosed Metal 2 x metal plates M20 x 1 5 connected by means of PE for metal cable...

Page 39: ...can be configured for each electric circuit by means of a coding switch The type of connection of the luminaire continuous light stand by light or switched light is freely programmable Mixed operatio...

Page 40: ...ure conditions chemical mechanical thermal and electric impact such as vibration humidity and corrosion see IEC EN 60079 14 The device must only be installed by trained qualified personnel who is fami...

Page 41: ...ng In event of wall mounting in outdoor areas avoid installation with central lock at top The mounting position with upward light emission in outdoor areas is prohibited For outdoor use we recommend t...

Page 42: ...7E00 Mounting bracket Top rail Lateral mounting pockets for variable suspension points When mounting the luminaire using top rails ensure that the mounting surface is flat Otherwise the enclosure migh...

Page 43: ...ing For pipe clamp mounting use the solution of R STAHL Schaltger te GmbH with integrated mounting rail providing reliable and stable four point fixing In case of point suspension using pipe clamps R...

Page 44: ...ous row mounting of the linear fluorescent luminaires EXLUX It facilitates the row mounting and installing of luminaires The rail profile can be also used as cable duct Always use mounting rails for m...

Page 45: ...t protection Note Version without switch Disconnect the luminaire from the power supply and secure it against being switched on again Version with switch The luminaire is positively disconnected from...

Page 46: ...can be clamped ingoing and outgoing wiring Note Clamping must be carried out precisely Do not clamp any part of the conductor insulation Do not interchange the conductors Observe the technical regulat...

Page 47: ...and 6 mm2 solid Stripping length 10 11 mm Stripping length 10 11 mm 15516E00 15438E00 Luminaire with address module Cage clamp terminals Clamping range 0 75 to 4 mm2 solid finely stranded 2 free clamp...

Page 48: ...ired L N Output to luminaire factory wired L N Control input Connection L factory wired to terminal D1 N factory wired to terminal D2 Switched light positive logic for switching on the luminaire toget...

Page 49: ...e operating an emergency lighting central battery system the luminaire addressing is to be performed by means of a screwdriver for slotted screws 4 mm 12 Logic switch 0 V negative logic 230 V positive...

Page 50: ...gs not supplied by R STAHL Schaltger te GmbH Please note the required dust resistance the required type of protection the required temperature resistance the IP degree of protection according to the r...

Page 51: ...maged no foreign bodies are inside the device the device is sealed according to regulations 9 Operation 9 1 Troubleshooting If the error cannot be eliminated using the mentioned procedures Contact R S...

Page 52: ...be carried out by appropriately authorized and qualified electricians Observe the relevant national regulations in the country of use Check Measures the permissible ambient temperature If exceeding th...

Page 53: ...t of the lamp the lamp fit will be locked after turning the lamp Replace the lamps in due time 06058E00 Open the luminaire Swivel the translucent cover backwards by 180 Lift the translucent cover to d...

Page 54: ...service form and fill it out Send the device along with the service form in the original packaging to R STAHL Schaltger te GmbH 11 Disposal Observe national and local regulations and statutory regulat...

Page 55: ...g marquage 2 D Extb IIICT 80 C Db CCoi58 EU Baumusterpr fbescheinigung PTB 14 ATEX 2016 EU Type Examination Certificate Physikalisch Technische Bundesanstalt Attestation d examen UE de type Bundesalle...

Page 56: ...uage II3G Ex ec IIC T4 Gc II3G Ex db ec IIC T4 Gc II3G Ex ec nC IIC T4 Gc C II 3G Ex db ec nC IIC T4 Gc II 3D Ex tc NIC T80 C De Konformit tsaussage PTB14 ATEX 2017 Conformity Statement Physikalisch T...

Reviews: