background image

Operating Instructions OS-IT-xx9 

General Information 

 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_07.docx / 06.12.2019 

Page 27 of 36 

11  General Information 

11.1  Touch driver 

 

The  UPDD  touch  driver  is  copyrighted  licensed  software  supplied 
strictly  for  use  with  original  R.  STAHL  HMI  Systems  GmbH  touch 
systems  and  under  no  circumstances  should  this  driver  be 
downloaded or used on any other equipment ! 

 

11.2  IT-479 (Panel PC) and IT-579 (Thin Client) 

11.2.1 

Up to Windows 7 operating systems 

11.2.1.1 

Licensing issues 

The SERIES 400 and 500 HMI devices usually have a Windows operating system pre-installed. 
The corresponding license sticker is affixed on the back of the operator interface, next to the type 
plate. 
Please note that according to the license issued for Windows the application of these systems as 
Office PC is not permitted. 
 

 

Please  also  note  the  information  on  the  licensing 
stipulations  for  Windows  operating  systems  contained  in 
the  "TechNote  Windows  Operating  Systems"  file  located 
on the CD / DVD / USB stick which is part of the delivery. 

 

11.2.2 

Note on Windows Embedded operating systems 

When  using  the  Windows  Embedded  7  operating  system  on  the  Panel  PC  SERIES  400  HMI 
devices, the C:\ system drive can be protected from unauthorised writing (EWF). 
 

 

This is not the case for other Windows operating systems! 

 

 

R.  STAHL  HMI  Systems  GmbH  recommends  you  leave  the  write 
protection filter on at all times. 

 

 

For  further  information  on  this  write  protection  (EWF), 
please refer to the OpenHMI_help_en.chm help file in the 
"STAHL" folder on the HMI device or on the CD / DVD / 
USB stick that is included in the delivery. 

 

11.2.3 

Windows® 10 IoT Enterprise 2016 LTSB operating system 

The operating system is based on Windows 10 for PC platforms with 64 bit x86 processors. For 
the  LTSB  (Long-Time-Service-Branch)  versions,  Microsoft  guarantees  10  years  of  security 
updates and new builds with feature updates only every 2-3 years, with these being optional. The 
LTSB  versions  are  ideal  for  industrial  applications  and  feature  additional  security  components 
such  as  write  filters  (UWF)  and  HORM  (start  of  a  system  snapshot  from  the  RAM  plus  write 
protection). 
 
From 2016 LTSB onwards, Microsoft has tied its licensing model to the processor performance: 
ENTRY 

for AMD® GX and ATOM™ 

VALUE 

for Intel® Core i5™ 

HIGH 

for Intel® Core i7™ 

 

 

DOCUMENTATION

 

 

NOTICE

 

 

DOCUMENTATION

 

 

ATTENTION

 

 

NOTICE

 

Summary of Contents for Manta GMP 400 Series

Page 1: ...ES 400 Panel PC SERIES 500 Thin Clients SERIES 700 Direct Monitors R STAHL HMI Systems GmbH Adolf Grimme Allee 8 D 50829 Cologne HW Rev IT 4x9 01 00 12 HW Rev IT 5x9 01 00 12 HW Rev IT 7x9 01 00 11 Op...

Page 2: ...ect to change without notice Any warranty claims are limited to the right to demand amendments Liability for any damage that might result from the contents of these instructions or all other documenta...

Page 3: ...ay result in injury if ignored Information highlighted by this symbol indicates measures for the prevention of damage to machinery or equipment Information highlighted by this symbol indicates importa...

Page 4: ...8 1 General safety information 14 8 2 Cautionary note 14 8 3 Installation safety information 14 8 3 1 Cable glands 15 8 4 Safety information for operation 15 9 Mounting and dismounting 15 9 1 General...

Page 5: ..._en_V_01_00_07 docx 06 12 2019 Page 5 of 36 11 2 7 Switching off closing down 29 11 2 8 Loss of data 29 12 Maintenance 30 13 Troubleshooting 30 13 1 Repairs hazardous substances 30 14 Disposal 30 14 1...

Page 6: ...use video and audio signals are also located here Unlike the IT 479 and IT 579 devices the IT 779 series only has a DVI input This device series is designed to be operated purely as a screen The MANTA...

Page 7: ...a distance of up to 5 m 16 4 ft As an option the devices that are intended to be operated purely as monitors can be fitted with a touch screen so that they can be operated as well as monitored The to...

Page 8: ...nge 100 240 VAC Frequency range 50 60 Hz Rated operational power typ 50 W 170 BTU Power consumption AC 1 1 A Fuses AC 4 AT Connections via standard plug Plug version AC IEC plug female Plug version US...

Page 9: ...emperature below 0 C 32 F the display will need a certain amount of time to warm up until everything is clearly visible Depending on how low the temperature is this process may last up to 3 hours Temp...

Page 10: ...4 2007 A1 2011 Interference emission EN 55032 2012 EMC interference emission EN 55024 2010 Interference resistance properties Low voltage directive Directive 2014 35 EU IEC 60950 1 2005 A1 2009 A2 20...

Page 11: ...jj kk ll mm AMD GX 217GA processor IT 479 aa bb cc dd ee ff gg hh R3 jj kk ll mm 4 GB RAM IT 479 aa bb cc dd ee ff gg hh ii MA kk ll mm 64 GB Solid State Drive MLC IT 479 aa bb cc dd ee ff gg hh ii M...

Page 12: ...kk ll mm AMD GX 217GA processor IT 579 aa bb cc dd ee ff gg hh R3 jj kk ll mm 4 GB RAM IT 579 aa bb cc dd ee ff gg hh ii MA kk ll mm 64 GB Solid State Drive MLC IT 579 aa bb cc dd ee ff gg hh ii M9 kk...

Page 13: ...een capacitive IT 779 aa bb cc dd W00 ff gg hh ii jj kk ll mm No WLAN IT 779 aa bb cc dd ee B0 gg hh ii jj kk ll mm No Bluetooth IT 779 aa bb cc dd ee ff C0 hh ii jj kk ll mm No internal card reader I...

Page 14: ...nd for the year of manufacture 8 2 Cautionary note This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate...

Page 15: ...otection sealing or strain relief might be negatively impacted Cable glands with cap nut and without strain relief clamp should only be used for permanently installed cables and electrical lines Insta...

Page 16: ...options dimensions 9 2 1 Tilted GMP device Enclosure design A B C tilted 15 673 mm 676 mm 370 mm 9 2 2 Vertical GMP device Enclosure design A B C vertical 673 mm 684 mm 373 mm 9 2 3 GMP device mounte...

Page 17: ...AHL HMI Systems GmbH OI_IT_xx9_en_V_01_00_07 docx 06 12 2019 Page 17 of 36 9 2 4 GMP device mounted on stand Enclosure design A B C D E F G tilted 15 673 mm 676 mm 1713 mm 403 mm 1310 mm 1500 mm 370 m...

Page 18: ...is installed in the same location They also all have the same dimensions for the keyboard enclosure 9 2 6 GMP device with barcode scanner fixed cable Bluetooth The barcode scanners can only be mounte...

Page 19: ...devices The GMP devices can be rotated 300 The space required for this should be kept free The dimensions for the various versions are listed in the table below Rotation radius A B C D Note GMP devic...

Page 20: ...docx 06 12 2019 9 2 8 Horizontal dual monitor with keyboard Dimensions A B C max 1466 mm 1717 mm Rotation radius without keyboard 716 mm The keyboard is always mounted beneath the main monitor of the...

Page 21: ...l dual monitor with keyboard without keyboard Dimensions A B C D E F G 673 mm 1142 mm 1500 mm 1965 mm 2193 mm 435 mm 610 mm Both operating devices are vertically tilted 15 and fixed They can therefore...

Page 22: ...Operating Instructions OS IT xx9 Mounting and dismounting Page 22 of 36 R STAHL HMI Systems GmbH OI_IT_xx9_en_V_01_00_07 docx 06 12 2019 9 2 10 Dual monitor with RFID reader...

Page 23: ...nstructions OS IT xx9 Mounting and dismounting R STAHL HMI Systems GmbH OI_IT_xx9_en_V_01_00_07 docx 06 12 2019 Page 23 of 36 9 2 11 Dual monitor with barcode scanner fixed cable Bluetooth fixed cable...

Page 24: ...l bonding terminal is properly connected to the equipotential bonding system at its place of use 10 2 Connections 10 2 1 SERIES 400 500 Designation Number View Connection Meaning 1 On off switch PWR P...

Page 25: ...ush button loudspeaker 12 VDC output Pin 1 GND external push button integrated in GMP enclosure 2 P 3 LSP Loudspeaker output optional 4 LSP 5 GND 12 VDC output 1 A 6 12 V DC F 13 for wire L Fuses 2x f...

Page 26: ...connector USB connection for touch data transmission connection type B USB2 0 4 DVI I connector DVI Monitor input 5 6 pin connector Not used blind plug F 6 for wire L Fuses 2x for wire N 7 Not used no...

Page 27: ...dded operating systems When using the Windows Embedded 7 operating system on the Panel PC SERIES 400 HMI devices the C system drive can be protected from unauthorised writing EWF This is not the case...

Page 28: ...icense key All necessary drivers are provided by R STAHL HMI Systems GmbH Please contact our Support department 11 2 4 Initial start up IT 479 Panel PC When started for the first time the Windows inst...

Page 29: ...operly see illustration below and not simply switched off Otherwise the existing image of the HMI device may be damaged rendering the device non functioning 11 2 8 Loss of data In the case of applicat...

Page 30: ...to return a unit if you are unable to completely remove any hazardous substances We shall bill you for any costs arising from insufficiently cleaned units such as disposal or damage to persons chemica...

Page 31: ...Operating Instructions OS IT xx9 Declaration of EC conformity R STAHL HMI Systems GmbH OI_IT_xx9_en_V_01_00_07 docx 06 12 2019 Page 31 of 36 15 Declaration of EC conformity...

Page 32: ...he operating instructions Version 01 00 06 Deletion of all previous release notes Addition of text concerning Mounting options in section Device function Addition of mounting options in chapter Techni...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...STAHL HMI Systems GmbH Adolf Grimme Allee 8 D 50829 Cologne T switchboard 49 0 221 76 806 1000 hotline 5000 F 4100 E switchboard office stahl hmi de hotline support stahl hmi de r stahl com stahl hmi...

Reviews: