background image

Preface 

Operating Instructions KBDi-USB Keyboards 

 R. STAHL HMI Systems GmbH / OI_KBDi_USB_en_V_01_00_07.docx / 28.09.2021 

Page 5 of 40 

Preface 

These  Operating  Instructions  contain  all  aspects  relevant  to  explosion  protection  for  the  
KBDi-USB-* keyboards devices. They also contain information on the connection and installation 
(etc.) of these devices. 
 

 

All data relevant to explosion protection from the EC-type examination 
certificate were copied into these operating instructions. 

For the correct operation of all associated components please note, in 
addition to these operating instructions, all other operating instructions 
enclosed  in  this  delivery  as  well  as  the  operating  instructions  of  the 
additional equipment to be connected ! 

 

 

Please  note  that  all  certificates  of  the  KBDi-USB-* 
keyboards  can  be  found  in  a  separate  document 
(CE_ET-xx7). 
You  can  find  this  document  in  the  internet  at  

www.r-stahl.com

  or  request  it  from  R.  STAHL  HMI 

Systems GmbH. 

 

Keyboard function 

The  type  KBDi-USB-*  keyboards  are  used  to  enter  data,  commands  etc.  on  PCs  and  similar 
devices in hazardous areas. In particular, they

 

were designed for connection to HMI devices of 

the device platform MANTA ET-/MT-xx7. 
 
The type KBDi-USB-* keyboards are explosion-protected equipment for installation in hazardous 
areas  of  zones  0  and  20.  The  devices  may  be  connected  to  intrinsically  safe  USB  interfaces. 
Power  supply  and  data  communication  takes  place  via  the  USB  interface.  The  keyboards  are 
connected with a fixed cable. 
Various keyboard versions are available that differ in their layout (German, US English, French, 
etc.) and in their design (PC keyboard with mouse, trackball, touchpad or with joystick). 
The touchpad uses resistive technology and can therefore be operated with a touch pen or with 
gloved fingers. 
The keyboards can be mounted inside a front panel or a desktop enclosure. 
 

 

 

NOTICE

 

 

DOCUMENTATION

 

Summary of Contents for KBDi-USB-J series

Page 1: ...Operating Instructions KBDi USB Keyboards Version KBDi USB TB50 Version KBDi USB M Version KBDi USB P Version KBDi USB J Operating Instructions Version 01 00 07 Issue 28 09 2021 ...

Page 2: ...e publisher Subject to alterations Any warranty claims are limited to the right to demand amendments Liability for any damage that might result from the contents of these instructions or all other documentation is limited to clear cases of premeditation We reserve the right to change our products and their specifications at any time provided it is in the interest of technical progress The informat...

Page 3: ...ignored This sign alerts users to hazards that may damage machinery or equipment or result in injury if ignored Information highlighted by this symbol indicates measures for the prevention of damage to machinery or equipment Information highlighted by this symbol indicates important information of which particular note should be taken Information highlighted by this symbol refers to a different ch...

Page 4: ...ety Information 11 10 2 Cautionary note 11 10 3 Installation safety information 11 10 4 Safety information for operation 12 10 5 Special conditions 12 11 Mechanical dimensions 13 11 1 Cut out 13 12 Connections 14 13 Maintenance overhaul 14 14 Troubleshooting 14 14 1 Repairs hazardous substances 14 15 Disposal Restricted substances 15 15 1 Declaration of substances and restricted substances 15 15 1...

Page 5: ..._ET xx7 You can find this document in the internet at www r stahl com or request it from R STAHL HMI Systems GmbH 2 Keyboard function The type KBDi USB keyboards are used to enter data commands etc on PCs and similar devices in hazardous areas In particular they were designed for connection to HMI devices of the device platform MANTA ET MT xx7 The type KBDi USB keyboards are explosion protected eq...

Page 6: ... KBDi USB J alphanumeric or symbolic characters without relevance to explosion protection For the exact new device name and model please refer to the type code 4 Technical Data Function Equipment KBDi USB Power supply via USB interface MTBF typically 50 000 h at 20 C Interfaces 1x USB for keyboard Ex ia 1x USB for mouse touch pad trackball joystick Ex ia Cable type standard USB open cable end Cabl...

Page 7: ... 60079 0 2012 A11 2013 General requirements EN 60079 11 2012 Intrinsic safety i Electromagnetic compatibility EMV directive 2014 30 EU Classification EN 61000 6 2 2005 Interference resistance EN 61000 6 4 2007 A1 2011 Interference emission Low voltage directive Directive 2014 35 EU EN 61010 1 2001 General requirements EN 62368 1 2016 IEC 62368 1 2014 Audio video information and communication techn...

Page 8: ... 1 General Requirements Third Edition ANSI UL 60079 0 sixth edition July 2013 Explosive atmospheres Part 0 Equipment General requirements ANSI UL 60079 11 sixth edition March 2014 Explosive atmospheres Part 11 Equipment protection by intrinsic safety i ANSI IEC 60529 2004 Degrees of protection provided by enclosures IP code 6 Certificates The KBDi USB keyboards are certified for installation in th...

Page 9: ...I3 ET 667 DVI3 T Ex 24T ET x77 with touch screen membrane 7 Marking Manufacturer R STAHL HMI Systems GmbH Type code KBDi USB TB50 KBDi USB M KBDi USB P KBDi USB J CE classification c 0158 Testing authority and certificate number BVS 11 ATEX E 102 X Ex classification ATEX e II 1 G Ex ia IIC T4 Ga II 1 D Ex ia IIIB T110 C Da IECEx Ex ia IIC T4 Ga Ex ia IIIB T110 C Da NEC CEC Ex ia IIC T4 Ga Ex ia II...

Page 10: ...th integrated trackball KBDi USB TB50 VA bb Keyboard with integrated stainless steel trackball KBDi USB M bb Keyboard with integrated mouse KBDi USB P bb Keyboard with integrated touch pad KBDi USB J bb Keyboard with integrated joystick KBDi USB aa DE Lanugage German QWERTZ KBDi USB aa US Language American QWERTY KBDi USB aa FR Language French AZERTY KBDi USB aa FR BE Language French Belgian versi...

Page 11: ...liance or contravention of the above explosion protection is no longer guaranteed and all warranty claims shall be null and void National safety and accident prevention rules apply Use the device for its intended purpose only No changes to the device are permitted The enclosure may only be opened by R STAHL HMI Systems GmbH 10 2 Cautionary note This is an EN 55022 Class A product In a domestic env...

Page 12: ...must be replaced If you want to use the device in category 1D 2D 3D or EPL Da Db Dc dust deposits of a thickness exceeding 5 mm must be removed and you have to ensure that no high energy loading mechanisms at the operating surface of the keyboard e g pneumatic particle transport occur during operation The keyboard may not be used in environments where propagating brush discharges may occur In case...

Page 13: ...echanical dimensions Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 13 of 40 11 Mechanical dimensions Dimensions in mm inch 11 1 Cut out ...

Page 14: ...age b Front membrane damage c All cables and lines are properly connected and undamaged If the device in its factory state is damaged or altered in any way decommission it immediately and contact the R STAHL HMI Systems GmbH 14 Troubleshooting Devices operated in hazardous areas must not be modified Repairs may only be carried out by qualified authorized staff specially trained for this purpose Re...

Page 15: ...itions 15 1 Declaration of substances and restricted substances The present declaration is based on the procedure described in the international standard and directives as listed in the table below IEC 62474 2018 DIN EN IEC 62474 2019 09 EG Nr 1907 2006 REACH Directive 2011 65 EU RoHS Resolution MEPC 269 68 International Maritime Organization IMO particularly 2015 Guidelines for the Development of...

Page 16: ...Operating Instructions KBDi USB Keyboards Control Drawing CEC NEC CSA Page 16 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 16 Control Drawing CEC NEC CSA ...

Page 17: ...Control Drawing CEC NEC CSA Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 17 of 40 ...

Page 18: ...Operating Instructions KBDi USB Keyboards Declarations of conformity Page 18 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 17 Declarations of conformity 17 1 EU ...

Page 19: ...Declarations of conformity Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 19 of 40 ...

Page 20: ...Operating Instructions KBDi USB Keyboards Declarations of conformity Page 20 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 17 2 RCM ...

Page 21: ...Declarations of conformity Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 21 of 40 ...

Page 22: ...Operating Instructions KBDi USB Keyboards Declarations of conformity Page 22 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 17 3 EAC ...

Page 23: ...Declarations of conformity Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 23 of 40 ...

Page 24: ...Operating Instructions KBDi USB Keyboards Declarations of conformity Page 24 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 17 4 CCC 17 4 1 English version ...

Page 25: ...Declarations of conformity Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 25 of 40 ...

Page 26: ...Operating Instructions KBDi USB Keyboards Declarations of conformity Page 26 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 ...

Page 27: ...Declarations of conformity Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 27 of 40 ...

Page 28: ...Operating Instructions KBDi USB Keyboards Declarations of conformity Page 28 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 ...

Page 29: ...Declarations of conformity Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 29 of 40 ...

Page 30: ...Operating Instructions KBDi USB Keyboards Declarations of conformity Page 30 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 17 4 2 Chinese version ...

Page 31: ...Declarations of conformity Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 31 of 40 ...

Page 32: ...Operating Instructions KBDi USB Keyboards Declarations of conformity Page 32 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 ...

Page 33: ...Declarations of conformity Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 33 of 40 ...

Page 34: ...Operating Instructions KBDi USB Keyboards Declarations of conformity Page 34 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 ...

Page 35: ...Declarations of conformity Operating Instructions KBDi USB Keyboards R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 Page 35 of 40 ...

Page 36: ...Operating Instructions KBDi USB Keyboards Declarations of conformity Page 36 of 40 R STAHL HMI Systems GmbH OI_KBDi_USB_en_V_01_00_07 docx 28 09 2021 ...

Page 37: ... to decommission the device Correction category WEEE II directive Addition of RCM declaration of conformity Formal changes Version 01 00 07 Changing layout cover Changing disclaimer new mail addresses Removal of reference to Online Manual in Preface Correction IP protection front in Technical data Adaption of Conformity to standards Changing section Certificates now tabular listing Addition of not...

Page 38: ......

Page 39: ......

Page 40: ...olf Grimme Allee 8 D 50829 Köln T Sales Support 49 221 768 06 1000 Technical Support 49 221 768 06 5000 F 49 221 768 06 4100 E Sales Support sales dehm r stahl com Technical Support support dehm r stahl com r stahl com exicom de ...