Permitted maximum values
Operating Instructions ET-xx6-A
R. STAHL HMI Systems GmbH / OI_ET_xx6_A_en_V_03_00_36.docx / 03.05.2021
Page 19 of 60
Reader RSi1 (power supply reader, X8.3-4):
The maximum values for group IIC are:
U
i
=
-
V
U
o
=
5.36
V
I
i
=
-
mA
l
o
=
220
mA
P
i
=
-
W
P
o
=
1.18
W
C
i
=
5.3
F
C
o
=
40.7
59.7
F
L
i
=
0
mH
L
o
=
2
1
H
C
o
and L
o
pairs directly above/underneath each other may be used.
The maximum values for group IIB are:
U
i
=
-
V
U
o
=
5.36
V
I
i
=
-
mA
l
o
=
220
mA
P
i
=
-
W
P
o
=
1.18
W
C
i
=
5.3
F
C
o
=
70.7
124.7
F
L
i
=
0
mH
L
o
=
20
10
H
C
o
and L
o
pairs directly above/underneath each other may be used.
Reader RSi1 and RSi2 (signal input / output, X8.5-8):
The maximum values for group IIC are:
U
i
=
15
V
U
o
=
5.36
V
I
i
=
500
mA
l
o
=
46
mA
P
i
=
2.5
W
P
o
=
62
mW
C
i
=
0
F
C
o
=
46
F
L
i
=
0
mH
L
o
=
2
H
The maximum values for group IIB are:
U
i
=
15
V
U
o
=
5.36
V
I
i
=
500
mA
l
o
=
46
mA
P
i
=
2.5
W
P
o
=
62
mW
C
i
=
0
F
C
o
=
79
F
L
i
=
0
mH
L
o
=
20
mH
Reader WCR1 (X8) (connection voltage supply, X8.1-2):
U
i
=
11.4
V
I
i
=
200
mA
P
i
=
2.28
W
C
i
=
25
nF
L
i
=
0
mH
Reader WCR1 (power supply reader, X8.3-4):
The maximum values for group IIC are:
U
i
=
-
V
U
o
=
5.88
V
I
i
=
-
mA
l
o
=
200
mA
P
i
=
-
mW
P
o
=
1.18
W
C
i
=
5.3
F
C
o
=
27.7
37.7
F
L
i
=
0
mH
L
o
=
2
1
H
C
o
and L
o