17

 

Disposal 

20

 

17.1

 

RoHS directive 2011/65/EC 

20

 

18

 

Declaration of EC conformity 

21

 

19

 

Release Notes 

22 

 
 
 

 

Summary of Contents for EC-750 Series

Page 1: ...Manual Operating Instructions DOME Camera EC 750 Ex R STAHL Camera Systems GmbH Adolf Grimme Allee 8 D 50829 Köln Version 01 01 10 Issue 31 03 2017 ...

Page 2: ...ritten consent of the publisher The information in this document is subject to change without notice Any warranty claims are limited to the right to demand amendments Liability for any damage that might result from the contents of these instructions or all other documentation is limited to clear cases of premeditation We reserve the right to change our products and their specifications at any time...

Page 3: ...alerts users to hazards that may result in death or serious injury if ignored This sign alerts users to hazards that may damage machinery or equipment or result in injury if ignored Information highlighted by this symbol indicates measures for the prevention of damage to machinery or equipment Information highlighted by this symbol indicates important information of which particular note should be...

Page 4: ...10 Safety Advice 12 10 1 Installation and operation 12 10 1 1 Zone 21 22 13 10 2 Special conditions 13 11 Installation 13 11 1 General information 13 11 2 EC 750 Ex DOME Camera 13 11 3 EC 750 xxx lens coverage 14 11 3 1 Horizontal lens coverage in actual figures 15 12 Assembly and disassembly 15 12 1 General information 15 12 2 Assembly 15 12 3 Mechanical dimensions 16 13 Operation 17 13 1 General...

Page 5: ...OME Camera EC 750 Ex Table of contents R STAHL Camera Systems GmbH HM_OI_Camera_EC_750_en_V_01_01_10 docx 31 03 2017 Page 5 of 24 17 Disposal 20 17 1 RoHS directive 2011 65 EC 20 18 Declaration of EC conformity 21 19 Release Notes 22 ...

Page 6: ... in this delivery as well as the operating instructions of the additional equipment to be connected Please note that all certificates of the Cameras can be found in a separate document CE_Camera_EC_750 You can find this document in the internet at www stahl camera de or request it from R STAHL Camera Systems GmbH 2 Camera function The EC 750 Ex DOME Cameras are explosion proofed cameras for applic...

Page 7: ...E S automatically Gain control automatically White Balance Mode automatically Lens 18x optical zoom focal lens 4 1 to 73 8 mm Viewing angle horizontal 48 wide angle lens 2 8 telephoto lens Minimum operating distance 290 mm wide angle lens 800 mm telephoto lens Focus Automatic with remote control override Lens movement Tilt 90 to 90 with flip facility Pan 360 without stop Revolving speed 0 to 42 s ...

Page 8: ...Vpp composite video at 75 ohm 3 3 EC 750 aa IP cc Complementing the technical data you find here the information for the EC 750 DOME camera with the integrated video server output Video compression Motion JPEG and MPEG4 Resolution 4 CIF 704 x 576 Frame rate Motion JPEG up to 30 25 fps at 4 CIF MPEG4 up to 30 25 fps at 2 CIF up to 20 17 fps at 4 CIF Security Password protection IP address filtering...

Page 9: ...N 60079 31 2009 Protected by enclosures t dust The product corresponds to requirements from EN 60079 0 2012 General requirements EN 60079 1 2014 Flameproof enclosure d EN 60079 31 2014 Protected by enclosures t dust Electromagnetic compatibility EMC directive until 19 04 2016 from 20 04 2016 Classification 2004 108 EG 2014 30 EU EN 61000 3 2 2006 A1 2009 A2 2009 General requirements EN 61000 3 3 2...

Page 10: ...IECEx certification is listed under the following certificate number Certificate number IECEx LCIE 14 0011X You can access all IECEx certificates on the official website of the IEC under their certificate number http iecex iec ch iecex iecexweb nsf welcome openform 6 Product identification Manufacturer R STAHL Camera Systems GmbH Type code EC 750 aa bb PE CE classification 0158 Testing authority a...

Page 11: ...is 20 C 55 C for cable gland at T6 and T85 C 20 C 60 C for cable gland at T5 and T100 C 9 Type code Camera EC 750 aa bb cc Connection variant Output variant CCD image sensor Camera version Product type Version Description Type with EC 750 aa bb cc Basic device as description EC 750 PA bb cc 1 4 CCD image sensor PAL EC 750 NT bb cc 1 4 CCD image sensor NTSC EC 750 aa VI PE Analog CVBS output Cable ...

Page 12: ...ndow The camera is mainly designed for a hanging down installation on the ceiling or wall Do not open when energized Do not open when an explosive atmosphere may be present The EC 750 Ex DOME Camera should be connected while unplugged Protect the EC 750 Ex DOME Camera against over voltage and voltage surge The camera had to be de energized before it is unplugged from the cabel system The EC 750 Ex...

Page 13: ... or dissolver The operating ambient temperature is for camera version with cable gland at T6 and T85 C 20 C Ta 55 C at T5 and T100 C 20 C Ta 60 C 11 Installation 11 1 General information Electrical plants are subject to certain regulations concerning installation and operation e g RL 1999 92 EC RL 2014 34 EU and IEC EN 60079 14 It is the responsibility of the operators of electrical installations ...

Page 14: ...ation Page 14 of 24 R STAHL Camera Systems GmbH HM_OI_Camera_EC_750_en_V_01_01_10 docx 31 03 2017 11 3 EC 750 xxx lens coverage The drawing below represents the horizontal lens coverage of the EC 750 camera version both in the telephoto and the wide angle mode ...

Page 15: ... 39 6 Consequently an object of a size between 0 05 m and 0 9 m can be viewed at a distance to the camera of 1 m 12 Assembly and disassembly 12 1 General information Assembly and disassembly are subject to general technical rules Additional specific safety regulations apply to electronic and pneumatic installations In case of replacement of the screws which fix the lid at the top of the camera hou...

Page 16: ...Operating Instructions DOME Camera EC 750 Ex Assembly and disassembly Page 16 of 24 R STAHL Camera Systems GmbH HM_OI_Camera_EC_750_en_V_01_01_10 docx 31 03 2017 12 3 Mechanical dimensions Plan view Side view ...

Page 17: ...amaged all screws are tightened fast 13 2 EC 750 Ex DOME Camera connections 13 2 1 EC 750 aa bb PE The camera variants EC 750 aa bb PE have a fixed connection cable 5 m for connection to a video server via an Ex e terminal box 13 2 1 1 EC 750 aa VI PE connection EC 750 aa VI PE EC 750 aa VI PE coverd Open end internal connection NOTICE 1 3 Red 0 6 mm Tx B Data B 4 Grey 0 14 mm 24 VDC Pink 0 34 mm ...

Page 18: ..._01_01_10 docx 31 03 2017 13 2 1 2 EC 750 aa IP PE connection EC 750 aa IP PE EC 750 aa IP PE covered Open end internal connection 1 2 Red 0 6 mm 1 2 GND TxD 3 TxD Pink 0 34 mm White 0 34 mm 24 VDC White 0 14 mm Black 0 6 mm RxD 6 Grey 0 14 mm Green Yellow 0 6 mm RxD Earth Power supply connector Ethernet connector RJ 45 1 2 3 6 ...

Page 19: ...cc The camera variants EC 750 aa IP cc contains an integrated IP server The video and data transmission is done on an Ethernet connection via IP Inside the camera an AXIS 282 server video card is installed This card integrates a Web server which makes it possible to display the video on a computer and to reach the control of the camera through the camera s software The AXIS IP UTILITY enables you ...

Page 20: ...ried out by qualified authorized staff specially trained for this purpose Repairs may only be carried out by specially trained staff who are familiar with all basic conditions of the applicable user regulations and if requested have been authorized by the manufacturer 17 Disposal Disposal of packaging and used parts is subject to regulations valid in whichever country the device has been installed...

Page 21: ...anual Operating Instructions DOME Camera EC 750 Ex Declaration of EC conformity R STAHL Camera Systems GmbH HM_OI_Camera_EC_750_en_V_01_01_10 docx 31 03 2017 Page 21 of 24 18 Declaration of EC conformity ...

Page 22: ...n of disclaimer Addition of section Specific markings Changing of all markings according to the new definition Changing of section Conformity to standards Addition of IECEx certification Rebuilt section certificates splitting into countries Changing addition of section Marking Adaptation section Disposal according to the newest WEEE and RoHS directive Renew Declaration of EC conformity Removal of ...

Page 23: ......

Page 24: ... Systems GmbH Adolf Grimme Allee 8 D 50829 Köln Phone switchboard 49 0 221 76 806 1200 hotline 5000 Fax 4200 E mail switchboard office stahl camera de hotline support stahl camera de www stahl de www stahl camera de ...