Technical Data 

 

   

Explosion Protection 

 

   

USA (FM)/Canada (FM) 

 

 

   

 

 

FM 16 US 0159 U  

 

 

  Class I, Zone 1, AEx db eb IIC T6…T5 Gb 

 

 

  Class I, Division 2, Groups ABCD (US) 

 

 

  FM 16 CA 0094 U 

 

   

 

 

Ex db eb IIC T6…T5 Gb  

 

   

 

 

Class I, Division 2 per CEC J18-150 (C) 

Other Certifications and Certificates:  

 

 

   

Ambient Temperature Range 

 

   

8008/2-0 and 8008/2-1 Control Switches 

 

   

T6:  -50ºC 

 Tamb 

 +60ºC 

 

   

8008/2-6 Load Switch 

 

   

T6:  -50ºC 

 Tamb 

 +50ºC 

 

   

T5:  -50ºC 

 Tamb 

 +60ºC 

 

   

Service Temperature Range 

 

   

-50ºC 

 Tamb 

 +80ºC 

 
 

   

Electrical Data 

8008/2-0 and 8008/2-1 Control Switches 
Contact Rating:  A600 (per ANSI/UL 508 and CSA C22.2 No. 14) 
Maximum current (resistive):  10 A 

8008/2-6 Load Switch 

Voltage Rating 

Phase 

Horsepower rating 

120 VAC 

3 phase 

2 hp 

240 VAC 

3 phase 

5 hp 

480 VAC 

3 phase 

10 hp 

600 VAC 

3 phase 

10 hp 

 

Maximum current (resistive) : 

16 A 

Note:  Per NEC 505.7(E), the short circuit current needs to be limited to less than 10,000 rms symmetrical 

amperes.  

 
Termination Capacity 
Contact terminal:  
8008/2-0 and 8008/2-1:  14 AWG…10 AWG (2.5 mm²...6 mm²), solid or stranded 
8008/2-6:  12 AWG…10 AWG (4 mm²…6mm²); solid or stranded 
Terminal is designed to hold two wires at the same time. 
 
Tightening torque:  1.8 Nm (contact terminals) 
 

  WARNING 

Please observe the technical data on the rating plate

 

Please consult the manufacturer if operating conditions are non-standard 

Summary of Contents for 8008/2

Page 1: ...ompetent personnel Read entire instructions before starting installation of this product Contact your R STAHL Customer Service or R STAHL distributor if you have any questions Technical information and illustrations are not binding and subject to change without notice The nature of these instructions is only informative and does not cover all of the details variations or combinations in which this...

Page 2: ...Standard for Safety for Electrical Apparatus for Explosive Gas Atmospheres Part 1 Flameproof enclosures d ANSI ISA 60079 7 Electrical Apparatus for Explosive Gas Atmospheres Part 7 Increased Safety e ANSI UL 508 Standard for Industrial Control Equipment 5 Safety Instructions Use the control and load switch only for its intended purpose Incorrect or impermissible use or non compliance with these in...

Page 3: ... Rating A600 per ANSI UL 508 and CSA C22 2 No 14 Maximum current resistive 10 A 8008 2 6 Load Switch Voltage Rating Phase Horsepower rating 120 VAC 3 phase 2 hp 240 VAC 3 phase 5 hp 480 VAC 3 phase 10 hp 600 VAC 3 phase 10 hp Maximum current resistive 16 A Note Per NEC 505 7 E the short circuit current needs to be limited to less than 10 000 rms symmetrical amperes Termination Capacity Contact ter...

Page 4: ...iedonthe control unit Refertothedevicelabel and technical informationfor properconnection Field wiring conductors shall be copper wires only stranded and sized based on the conductor rated for 75 C for North American Installations Per NEC 505 7 E the short circuit current needs to be limited to less than 10 000 rms symmetrical amperes 8 Maintenance WARNING To avoid electrical shock fire and or exp...

Page 5: ...80 086 09 30 0 251341 5 5 S I0M 8008 01 en 2016 07 18 9 Dimensions in Millimeters ...

Reviews: