3.3

Intended Use

The luminaire is equipment

The floodlight 6521 is equipment

• for lighting areas, work spaces and objects

• can be used indoors and outdoors

• for stationary mounting

• for use in Zones 21, 2, 22 and in the safe area

• for use in the safe area

3.4

Modifications and alterations

4

Function and device design

4.1

Function

• for lighting areas, work spaces and objects

DANGER

Explosion hazard due to modifications and alterations to the device! 

Non-compliance results in severe or fatal injuries.

• Do not modify or alter the device.

No liability or warranty for damage resulting from modifications and  

alterations.

DANGER

Explosion hazard due to improper use!

Non-compliance results in severe or fatal injuries.

• Use the device only in accordance with the operating conditions  

described in these operating instructions.

• Use the device only for the intended purpose specified in these  

operating instructions.

Summary of Contents for 6521/4 Series

Page 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages www stahl ex com EN Floodlight Series 6521 4...

Page 2: ...nical data 7 6 Transport and storage 11 6 1 General 11 7 Mounting and installation 12 7 1 Dimensions fastening dimensions 12 7 2 Mounting dismounting operating position 13 7 3 Installation 14 8 Commis...

Page 3: ...egally binding in all legal affairs 1 3 Conformity with standards and regulations See certificates and EC Declaration of Conformity www stahl ex com The device has IECEx approval See IECEx homepage ht...

Page 4: ...We cannot be held liable for damage caused by incorrect or unauthorized use or by non compliance with these operating instructions Before installation and commissioning make sure that the device is no...

Page 5: ...ions and alterations 4 Function and device design 4 1 Function for lighting areas work spaces and objects DANGER Explosion hazard due to modifications and alterations to the device Non compliance resu...

Page 6: ...III de 00 Floodlight Series 6521 4 EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN 4 2 Device design 17215E00 1 Lamp enclosure 4 Mounting bracket 2 Cable gland 5 Lamp holder...

Page 7: ...le Certifications and certificates Certificates IECEx ATEX India PESO Temperature class at Ta To max at Ta Type Lamp Power 40 C 50 C 40 C 50 C 6521 41 QT 150 W T3 T3 156 C 166 C QT 250 W T2 T2 202 C 2...

Page 8: ...HIT 0 38 A 0 50 A 0 96 1 00 A 1 30 A 0 37 100 W HST HIT 0 56 A 0 80 A 0 90 1 20 A 1 70 A 0 41 150 W HST HIT 0 79 A 1 50 A 0 95 1 80 A 2 70 A 0 40 250 W HST HIT 1 30 A 2 00 A 0 92 3 00 A 4 20 A 0 40 40...

Page 9: ...ctor Rated operating current Inrush current Power factor 70 W HST HIT 0 36 A 0 50 A 0 95 1 00 A 1 30 A 0 37 100 W HST HIT 0 62 A 0 80 A 0 91 1 20 A 1 70 A 0 44 150 W HST HIT 0 75 A 1 50 A 0 96 1 80 A...

Page 10: ...shocks Seal Silicone Reflector Aluminium anodised Enclosure lock Pan head screw M6 stainless steel Hinged enclosure cover Technical Data compensated Type QT QT HIT HST HST 500 W 1000 W 70 W 100 W 150...

Page 11: ...lation Operating position Horizontal lamp axis Cable entry Standard 1 x M20 x 1 5 cable gland clamping area d 4 13 mm 1 x M20 x 1 5 stopping plug 1 x M20 x 1 5 cable entry with blind plugs as test hol...

Page 12: ...chemical mechanical thermal and electric impact such as vibration humidity and corrosion see IEC EN 60079 14 The device must only be installed by trained qualified personnel who is familiar with the r...

Page 13: ...Pole mounting attachment Accessories DANGER Explosion hazard due to inadmissible heating Non compliance results in severe or fatal injuries Avoid external heat sources and or direct sunlight risk of c...

Page 14: ...ate see information plate on the lock 17216E00 Loosen the M6 cover screws Open the cover Insert the cable 17217E00 Connect the conductor to the spring clamp terminal Check that the cable is clamped pr...

Page 15: ...onfirmation of the manufacturer for the combination of the cable and screw connection 8 Commissioning Before commissioning ensure the following Check the mounting and installation Inspect enclosure fo...

Page 16: ...ve the following information ready Type and serial number of the device Purchase information Error description Intended use in particular input output wiring DANGER Explosion hazard due to incorrect i...

Page 17: ...WARNING Risk of electric shock or malfunctioning of the device due to unauthorized work Non compliance can result in severe injuries and material damage Work performed on the device must only be carr...

Page 18: ...mponents are non exchangeable the device must be taken out of operation its intended use If the device is not used according to its intended use it must be taken out of operation if the conductors are...

Page 19: ...2 1 1 In order to test restricted breathing pressure test the luminaire is equipped with a cable entry with red stopping plugs Remove the red stopping plug Insert the hose of the test device into the...

Page 20: ...com under Downloads Customer service Download the service form Fill out the service form Send the device along with the service form in the original packaging to R STAHL Schaltger te GmbH Alternative...

Page 21: ...te materials when sending it for recycling Ensure environmentally friendly disposal of all components according to the statutory regulations 12 Accessories and Spare parts NOTE Malfunction or damage t...

Page 22: ......

Page 23: ......

Reviews: