background image

Technical data

8

264191 / 6161621300

2019-06-17·BA00·III·en·05

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN

Flashing Beacon and Continuous Beacon

Series 6161

For further technical data, see r-stahl.com.

Luminous characteristics

Version

6161/2 Flashing Beacon

6161/3 Continuous Beacon

Flashing energy

5  Joules  

–  

Flashing frequency

1  Hz 

–  

Duty cycle

100 % 

100 % 

Service life

6 x 10

6

 flashes

Ambient conditions

Ambient temperature * Temperature class

* Temperature class

Mechanical data

Degree of protection IP66 according to IEC/EN 60529
Protection class

I  (internal and external PE connection terminal according to IEC/EN 60598)

Material

Enclosure

aluminium alloy copper-free, yellow/black powder-coated

Light dome

polycarbonate, prismatic

Wire guard

stainless steel

Fixing elements

stainless steel

Sealing ring

NBR-O-ring seal

Special lock

Ex d enclosure; M4 hexagon socket stud

Mounting / Installation

Cable entries

1 x M20 x 1.5 stopping plug

1 x M20 x 1.5 cable gland

metal cable gland on request

Clamping range

4 to 13 mm

Connection type

screw terminal block, 3-pole

Marking

L1 + N + PE

Connection  

cross-section

Solid

2 x 4 mm

2

finely stranded

2 x 2.5 mm

2

Protective conductor 

connection

Inside

max. 6 mm

2

Outside

max. 2.5 mm

2

 flexible / 4 mm

rigid

Technical Data

Type

T

amb

Gas Dust

6161/2 +40 °C T6

T85 °C

+50 °C T5

T100 °C

Type

T

amb

Gas Dust

6161/3 +40 °C T6

T65 °C

+50 °C T6

T75 °C

Summary of Contents for 6161 Series

Page 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages r stahl com EN Flashing Beacon and Continuous Beacon Series 6161 ...

Page 2: ...es 4 2 3 Symbols on the device 5 3 Safety notes 5 3 1 Operating instructions storage 5 3 2 Safe use 5 3 3 Modifications and alterations 6 4 Function and device design 6 4 1 Function 6 5 Technical data 7 6 Transport and storage 9 7 Mounting and installation 9 7 1 Dimensions fastening dimensions 9 7 2 Mounting dismounting operating position 10 7 3 Installation 11 8 Commissioning 11 9 Operation 12 9 ...

Page 3: ...ents in additional languages see r stahl com 1 4 Conformity with standards and regulations See certificates and EU Declaration of Conformity r stahl com The device has IECEx approval For certificate please refer to the IECEx homepage http iecex iec ch Further national certificates can be downloaded via the following link https r stahl com en global support downloads R STAHL Schaltgeräte GmbH Busin...

Page 4: ...nd source of danger damage Consequences of danger Taking countermeasures to avoid the danger or damage Symbol Meaning Tips and recommendations on the use of the device General danger Danger due to explosive atmosphere Danger due to energised parts DANGER Danger to persons Non compliance with the instruction results in severe or fatal injuries to persons WARNING Danger to persons Non compliance wit...

Page 5: ... data We cannot be held liable for damage to the device caused by incorrect or unauthorised use or non compliance with these operating instructions For assembly and installation Observe national assembly and installation regulations e g IEC EN 60079 14 Observe national safety and accident prevention regulations During installation and operation observe the information characteristic values and rat...

Page 6: ...ts or areas of harsh environmental conditions The product variants can be used in ATEX and IECEx zones 1 2 and 21 22 DANGER Explosion hazard due to modifications and alterations to the device Non compliance results in severe or fatal injuries Do not modify or alter the device No liability or warranty for damage resulting from modifications and alterations DANGER Explosion hazard due to improper us...

Page 7: ... see ambient conditions for temperature class Certifications and certificates Version 6161 2 Flashing Beacon 6161 3 Continuous Beacon Certificates IECEx ATEX India PESO China China EX EAC TR CU Korea KGS Ship approval GL Technical Data Electrical data Version 6161 2 Flashing Beacon 6161 3 Continuous Beacon Rated values Back up fuse 4 AT Fuse slow blow or automatic circuit breaker C characteristic ...

Page 8: ...nal PE connection terminal according to IEC EN 60598 Material Enclosure aluminium alloy copper free yellow black powder coated Light dome polycarbonate prismatic Wire guard stainless steel Fixing elements stainless steel Sealing ring NBR O ring seal Special lock Ex d enclosure M4 hexagon socket stud Mounting Installation Cable entries 1 x M20 x 1 5 stopping plug 1 x M20 x 1 5 cable gland metal cab...

Page 9: ...Transport and store the device only in the original packaging Store the device in a dry place no condensation and vibration free Do not drop the device 7 Mounting and installation 7 1 Dimensions fastening dimensions Dimensional drawing all dimensions in mm inches Subject to change 09345E00 6161 flashing beacon Mounting accessories 04716E00 09346E00 04595E00 Ceiling and wall mounting bracket Pipe c...

Page 10: ...ounting dismounting operating position 7 2 1 Mounting on mounting plate 7 2 2 Installation with pipe clamp 7 2 3 Installation with mounting bracket 04177E00 12802E00 Mounting plate for lateral wall and or bottom assembly 04163E00 04164E00 Mounting of pipe clamps for a pipe diameter 1 1 2 1 1 4 or 2 04162E00 04204E00 Wall or floor mounting bracket See datasheet for part numbers and ordering informa...

Page 11: ...sed Check whether all the cable entries and stopping plugs have been tightened firmly Check if all conductors have been clamped firmly Check if the line voltage and the rated operational voltage are consistent Check if the permissible conductor diameter for the corresponding cable entries have been used Check if the device is closed according to regulations WARNING Danger of electric shock due to ...

Page 12: ...minated using the mentioned procedures Contact R STAHL Schaltgeräte GmbH For fast processing have the following information ready Type and serial number of the device Purchase information Error description Intended use in particular input output wiring 10 Maintenance overhaul repair 10 1 Maintenance WARNING Risk of electric shock or malfunctioning of the device due to unauthorized work Non complia...

Page 13: ... its intended use If the device is not used according to its intended use it must be taken out of operation if the conductors are clamped properly clamp loose conductors tightly the cables for ageing and damage replace damaged or aged cables if the surface of the flameproof Ex joint is damaged If the flameproof Ex joint is damaged the device must be taken out of operation if corrosion on the flame...

Page 14: ...rm in the packaging to R STAHL Schaltgeräte GmbH refer to chapter 1 1 for the address 11 Cleaning Clean the device only with a cloth brush vacuum cleaner or similar items When cleaning with a damp cloth use water or mild non abrasive non scratching cleaning agents Do not use aggressive detergents or solvents 12 Disposal Observe national and local regulations and statutory regulation regarding disp...

Page 15: ......

Reviews: