Instructions for setting the ACW01 injector stroke

Note:

ACW01 injector rail stroke setting is not equivalent to factory calibration and a 

performance guarantee for a new injector rail.

Required tools:  

- calibrating device kit 

- Allen key # 4 

- power supply 12.5 – 13.5VDC 6A

2.  Connect the power cable plug  

to the injector.

1.  Screw the calibrating device into the injector 

rail nozzle; the pointer on the small scale 

should be kept within the range of 2÷4 mm. 

Otherwise, loosen the lock screw “1” and 

adjust the position of the dial gauge “2”. 

Relock the screw “1” and turn the holder 

of the sensor “3” to set zero on the sensor 

pointer.

3. Connect the cable to the power supply.