ST535C Handbook
32
Setup Parameters (32
-
63)
No.
Function
Min.
Max.
Default
Notes
32
Integral time (zone 3)
0
9999
0
Seconds, 0=disabled
33
Differential time (zone 3)
0
999
0
Seconds, 0=disabled
34
Kiln element power (zone 3)
0
9999
0
1 unit = 0.1kW
40
Number of zones
1
3
3
41
Control Strategy
0
1
1
0=differential, 1=absolute
42
Not used
0
1
0
0=disabled, 1=enabled
43
Engineer lockup on error
0
1
0
0=disabled, 1=enabled
44
Control cycle time
5
120
30
Seconds
45
Event1 / Damper / Fan relay function
0
3
0
0=disabled, 1=event,
2=damper, 3=fan
46
Remember start delay
0
1
0
0=forget, 1=remember
47
Skip start delay after power failure
0
1
0
0=resume delay, 1=skip
delay
48
Reset to factory defaults
0
1
0
1=reset
49
Event2 / Forced cooling relay
function
0
2
0
0=disabled, 1=event2
2=forced cooling
50
USB Datalogging sample rate
5
300
60
seconds
51
USB Datalogging string format
0
1
1
0=short form
1= long form
55
Disable setup password protection
0
1
1
0=enabled, 1=disabled
60
Operating units °C/°F
0
1
0
0=°C, 1=°F
Note: The setup parameters shown thus are freely adjustable. The other setup
parameters might be password protected
-
contact supplier.