background image

Page 

     ST315 

User 

Handbook 

18 

Other Features 

Energy Used Display 

Pressing the 

§

 button at any time shows the amount of electrical energy used 

in kW hours.  If pressed during a firing it shows the energy used so far.  After 
a firing it shows the total energy used for that firing.  This information is 
stored while power is off and is only reset to zero when a new firing is 
started. 
 
If the value displayed is always 

0

.

0

 then the kiln power rating has not been 

configured into the ST315—see installation handbook. 

Keyboard Lock Facility 

1

.

200

 

°C 
°C/hr 
hr.min 

The keys on the ST315 can be locked so that pressing them has no effect.  
This is an anti-tamper feature used to ensure that the operation of the ST315 
or the program data cannot be altered by un-authorised people.  The ST315 
can be locked when it is idle (not firing) or while it is firing.  It cannot be 
locked while it is being programmed. 

If the left-hand decimal point in the 
display is lit then the ST315 is locked.  
Press and hold in both the 

©

 & 

ª

 keys  

for 5 seconds to unlock the ST315. 

1200

 

°C 
°C/hr 
hr.min 

If the left-hand decimal point in the dis-
play is not lit then the ST315 is not 
locked.  Press and hold in both the 

©

 & 

ª

 keys  for 5 seconds to lock the ST315. 

Power Failure Recovery 

If power fails during firing then the ST315 recovers as follows:- 
For power failure during start delay the ST315 commences firing immedi-
ately when power returns.  For power failure during ramping the ST315 con-
tinues the ramp it was previously executing.  For power failure during soak-
ing the ST315 ramps back up to soak temperature at the correct ramp rate 
then applies the full soak period.  This recovery scheme can be disabled if 
required (see installation handbook) - the ST315 will then lock up with 

FAIL

 

displayed and kiln off in the event of power failure. 

Other

 Featur

es 

ST315 User Handbook 

 

 

 

 

       Page   3 

Quick S

tart Guide 

Quick Start Guide 

Switch on & wait for kiln temperature display

 

To run a firing program set up previously press the 
START/STOP key

 

To stop the firing at any time press the START/
STOP key again

 

To review firing data press the 

¨

 key to enter the 

programming menu

 

To change firing data press the 

©

 & 

ª

 keys to 

change the displayed value

 

Use the 

¨

 key again as necessary to index to the 

next firing value or segment to be reviewed or 
changed

 

To mark the end of a program set a ramp rate to 

End 

with the 

ª

 key 

If the keyboard is locked then press the 

©

 & 

ª

 keys 

together & hold down for 5 seconds to unlock

 

To exit the programming menu either wait 10 sec-
onds or press the START/STOP key to start firing 

Summary of Contents for ST315

Page 1: ...User Handbook Page 1 ST315 User Handbook STAFFOR D INSTRUMENTS Stafford Instruments Ltd Tel 44 0 1785 255588 Fax 44 0 1785 255589 www stafford inst co uk email support stafford inst co uk Issue 1 002 Date 01 Dec 2005 ST315 Temperature Programmer See separate handbook for Installation Instructions Copyright 2004 2005 Stafford Instruments Ltd ...

Page 2: ...ELAYED START LAMP SOAK TIME LAMP SOAK TEMPERATURE LAMP COOLING RAMP LAMP At A Glance FIRING LAMP Temperature Programmer ST315 C C hr hr min STEP UP DOWN BACK kWh START STOP Delay ºC t Cooling Heating Soaking PROGRAM SEGMENT Delay ºC t Cooling Heating Soaking HEATING RAMP LAMP ST315 User Handbook Page 19 Notes ...

Page 3: ...ª keys for 5 seconds to lock the ST315 Power Failure Recovery If power fails during firing then the ST315 recovers as follows For power failure during start delay the ST315 commences firing immedi ately when power returns For power failure during ramping the ST315 con tinues the ramp it was previously executing For power failure during soak ing the ST315 ramps back up to soak temperature at the co...

Page 4: ... the ST315 to terminate the firing with all the keys locked An alarm buzzer sounds once per second SWITCH KILN OFF To reset the ST315 turn off the power to the instrument and have the fault investigated by your installer or kiln service engineer to rectify the fault Technical note any error message will cause the auxiliary alarm relay if fitted to open see installation handbook for details Note th...

Page 5: ...99 hours limit Err6 C C hr hr min Possible causes are contactor failure or thermocouple connection intermittent or high resistance ST315 User Handbook Page 5 Turning On F1 04 tC r tC S tC n tC K 8 8 8 8 When turned on the ST315 performs a display test by briefly illuminating all of the display digits and all of the front panel lamps The version number of the software embedded within the ST315 is n...

Page 6: ...ay ºC t Cooling Heating Soaking ST315 User Handbook Page 15 Program Pause Facility While firing press and hold down the ª key for about 4 seconds The ST315 will pause the executing program To un pause the program press and hold down the the ª key again for about 4 seconds The effects of pausing are as follows If paused during ramping the kiln temperature will be held soaked in definitely at the cu...

Page 7: ...he operation of the ST315 in this way are temporary and are not stored Adjusting While Firing ST315 User Handbook Page 7 When the ST315 is not firing there are no lamps lit on the mimic panel the run lamp is off and the display shows the kiln temperature with the C indicator lit Altering a program 20 C C hr hr min If the left hand decimal point is on then the keyboard is locked Press the ª keys to...

Page 8: ...1 999 FULL If End is shown but another segment is required then push the key to obtain the required ramp rate in the range 1 C hr to 999 C hr If full power is required then push the key until FULL is diplayed ST315 User Handbook Page 13 Cooling Upon completion of firing the ST315 lights all lamps on the mimic dis play and the kiln is allowed to cool naturally 120 C C hr hr min Hot C C hr hr min 39...

Page 9: ...turned this feature can be disabled see in stallation handbook Firing Delayed Start The delayed start time period is set to 00 00 when the ST315 is turned on ST315 User Handbook Page 9 Firing To start a firing press the START STOP key The RUN lamp will light To stop the firing prematurely press the START STOP key again 20 C C hr hr min If the left hand decimal point is on then the keyboard is lock...

Page 10: ...Page ST315 User Handbook 10 Program Record Sheet Segment No Ramp C hr Soak Temp C Soak Time hr min Please photocopy me ST315 User Handbook Page 11 Notes Please photocopy me Program No ...

Reviews: