Do not use radio systems in places with strong interference (for example, near police
stations, airports, banks, hospitals). It is in any case advisable to carry out a technical
inspection prior to installing any radio system in order to identify possible sources of
interference.
Radio systems can be used where any disturbances or malfunction of the transmitter or receiver do not
constitute a risk factor, or if such factor is eliminated using appropriate safety systems.
The presence of radio devices working at the same transmission frequency (433.42 MHz) may interfere
with the radio receiver and reduce the range of the system, limiting functionality.
120-230V
50-60Hz
I max = 5(3) A
L
N
Main
power supply
FUSE
500 mA
www.stafer.com
433,42 MHz
User manual:
Dear Customer,
Thank you for purchasing a STAFER S.p.A.
product.
This guide contains all the information you will
need concerning the use of this product. Read
the instructions carefully and keep them for
further consultation.
The receiver module 594.R.EN.00 is a radio
receiver with dry output contacts and adjustable
working time.
All other use beyond the field defined by
STAFER S.p.A. is forbidden. This, as well as
the breach of the instructions given in this
guide, shall release STAFER S.p.A. from any
liability and shall annul the product warranty.
NOTE:
This product is compatible with Arco
and equivalent transmitters.
Before starting the programming procedure,
read the instruction manual of the transmitter.
In the following description the transmitter
is represented in a generic way.
ü
n° 1 594.R.EN.00
ü
n° 1 wall bracket
ü
this manual
Contents of package
ü
Check that the package is intact and has not been damaged in transit.
ü
The product is designed to be inserted inside of junction boxes. The module does not provide any
protection against water and only essential protection for contact with solids.
ü
It is forbidden to install the module in areas not adequately protected, and near sources of heat.
ü
Use momentary (hold-to-run) control buttons. Do NOT use stay-put switches.
ü
Position the buttons within sight of the roller shutter/awning but a long way from its moving parts.
Position the buttons more than 1.5 m from the floor.
ü
Install the product carefully, using suitable tools.
ü
If there are several radio appliances in the same system, they must not be less than 1.5 m apart.
ü
Do not install the product near metal surfaces.
ü
Do not modify or replace parts without the manufacturer's permission. Do not pierce or tamper the box.
ü
The antenna cable carries line voltage. Do not cut the antenna cable as this would be dangerous. If the
antenna cable is damaged, replace the product.
01B. WARNING FOR INSTALLATION
At the end of the product life cycle, dispose of the device in compliance with local regulations.
This product could contain substances that are harmful to human health and the
environment: do not dispose of the product in domestic waste
.
Disposal
ü
Power supply:
120 or 230 Vac, 50/60 Hz
ü
Contacts capacity:
5A @ 250 Vac
ü
Dimensions:
45 x 38 x 25 mm
ü
Weight:
40 gr
ü
Working temperature:
from -20 to +55°C
ü
IP protection:
IP20
ü
Working time:
from 1 to 240s
ü
Frequency:
433.42 MHz
ü
Memorizable transmitters:
15*
ü
Memorizable sun sensor:
1
ü
Memorizable wind sensor:
4
ü
Range (estimes):
100 m outdoor, 20 m indoor
(*) rain sensor included
Technical specifications
ü
The product is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they are supervised or given
instructions on how to use the product by a person responsible for their safety.
ü
Before operating the roller shutter/awning, make sure there are no people or objects in the area
involved in its movement. Check the automation during movement and keep people at a safe
distance, until the movement ends.
ü
Do not allow children to play with the appliance or with the fixed control devices. Also, keep the
portable control devices (remote controls) out of the reach of children.
ü
Do not operate the roller shutter/awning when maintenance operations are being carried out (e.g.
window cleaning). If the control device is automatic, disconnect the motor from the power line.
01C. WARNING FOR USE
02. ELECTRICAL CONNECTION
ü
Make the connections with the power switched off.
ü
Check that the power line does not come from electrical circuits intended for lighting.
ü
A circuit breaker or residual current device must be inserted in the power line. An isolating device with
overvoltage category III, namely distance between contacts of at least 3.5 mm, must be inserted in the
power line
ü
The product has no protection against overloads or short circuits. Install a protective device in the
power line that is appropriate for the load, such as a fuse of max. 500mA.
ü
You can not connect more than one motor directly to the module.
ü
Use momentary (hold-to-run) control buttons. Do NOT use stay-put switches. The control buttons are
connected to the line voltage and must therefore be properly isolated and protected.
Power supply
The module can be powered from 120Vac to 230Vac. The supply voltage must be applied to terminals
1
and
2.
Connecting the motor
The module MIR DRY can't be connected directly to the load (eg. an electric motor) as it doesn't provide
any output voltage. You must connect it to another device via the clamps 6, 7 and 8 which are dry contact,
with the common in clamp 6.
Connecting the command buttons (optional)
The buttons must be connected to terminals
3
and
4
, the common thread of the buttons must be
connected to terminal
5
.
The command buttons are subjected to the mains voltage and therefore
must be properly insulated and protected.
You must use
momentary (hold-to-run) command
buttons
, do not use buttons with maintained position. More than one command button can be connected
to the unit through a parallel connection. To make an up or down movement, press the button for at least
0.5 seconds; to stop the operation briefly press any of the buttons.
ü
Incorrect installation can cause serious injuries.
ü
Keep these instructions for future maintenance work and disposal of the product.
ü
All the product installation, connection, programming and maintenance operations must be carried out
only by a qualified and skilled technician, who must comply with laws, provisions, local regulations and
the instructions given in this manual.
ü
The wiring must comply with current IEC standards.
ü
Some applications require hold-to-run operation and can exclude the use of radio controls or require
particular safety devices.
ü
To prevent potentially dangerous situations, check the operating condition of the roller shutter/awning
regularly.
01A. WARNING FOR SAFETY
01. WARNINGS!
01
. Warnings
02
. Electrical connection
03
. First installation
04
. Memorization\deletion of a radio device
05
. Operating logic of wind sensor
06
. Operating logic of sun sensor
07
. Operating logic of rain sensor
08
. Working time
09
. Orientation function
10
. «Air Change» function
11
. RESET
Index
Notes on radio systems
594.R.EN.00
C
CP
L
N
120-230V
50-60Hz
1
2
3
4
5
6
7
8
Dry contacts
WARNING:
the figures used in the following paragraphs are generically referred to a motor
that moves a roller blind. Depending on the load applied to the module, the terms
UP and DOWN can have different meanings
(eg. LEFT and RIGHT or OPEN and CLOSE).
This procedure is used to memorize the first transmitter.
03. FIRST INSTALLATION
NOTE:
In the event that the installation is not successful, you can restore your system to factory condition (see
section 11. RESET).
ON
Supply the module
A
The motor
makes 4
movements...
B
C
within 15s press
x4
within 15s press
The motor makes a brief upward
movement
IF
IF
x4
UP
DOWN
x1
594.R.EN.00