background image

Stabila LD 320

Measuring Functions

7

EN

Pythagoras (2-point)

1

3x

2

Aim laser at up-

per point.

3

4

Aim laser rectan-

gular at lower 

point.

8.294 

m

5

i

The result is shown 

in the main line and 

the measured dis-

tance above. 

Pressing the meas-

uring key for 2 sec 

in the function acti-

vates automatically 

Minimum or Maxi-

mum measure-

ment. 

Pythagoras (3-point)

1

4x

2

Aim laser at up-

per point.

3

4

Aim laser at rec-

tangular point.

5

6

Aim laser at lower point.

8.294 

m

7

i

The result is shown in the main 

line and the measured distance 

above. 

Pressing the measuring key for 

2 sec in the function activates 

automatically Minimum or Maxi-

mum measurement. 

Summary of Contents for Laser Distancer LD 320

Page 1: ...ring single distance 5 Permament measuring 5 Area 6 Volume 6 Pythagoras 2 point 7 Pythagoras 3 point 7 Minimum Tracking 8 Maximum Tracking 8 Technical Data 9 Message Codes 10 Care 10 Warranty 10 Safety Instructions 10 Areas of responsibility 10 Permitted use 11 Prohibited use 11 Hazards in use 11 Limits of use 11 Disposal 11 Electromagnetic Compatibility EMC 11 FCC statement applicable in U S 12 L...

Page 2: ...potentially hazardous situation or an unintended use which if not avoided will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or appreci able material financial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a t...

Page 3: ...p 3 EN Display Battery Units Area Volume Min Max Measuring Measuring reference Info Pythagoras Main line Insert batteries i To ensure a reli able use do not use zinc carbon batteries Change batter ies when battery symbol is flash ing ...

Page 4: ...fo icon appears with a number observe the instruc tions in section Message Codes Example Adjusting measuring reference Distance is measured from the front of the device 1 Distance is measured from the rear of the device standard setting 2 Distance unit setting Beep ON OFF Switch between the following units 0 000m 0 00m 0 00ft 0 00 1 16 0 00in 0 1 16in 2 sec 2 sec simultaneously ...

Page 5: ...asuring errors can occur when meas uring to colourless liquids glass styrofoam or semi per meable surfaces or when aiming at high gloss surfac es Against dark surfaces the measuring time increases Permament measuring 1 2 sec 8 532 m Aim active laser at target 2 The last value mea sured is displayed Stops permanent measur ing 3 ...

Page 6: ...t sec ond target point 24 352 m2 5 i The result is shown in the main line and the measured value above Volume 1 2x 2 Aim laser at first target point 3 4 Aim laser at sec ond target point 5 6 Aim laser at third target point 78 694 m3 7 i The result is shown in the main line and the measured valueabove ...

Page 7: ...Pressing the meas uring key for 2 sec in the function acti vates automatically Minimum or Maxi mum measure ment Pythagoras 3 point 1 4x 2 Aim laser at up per point 3 4 Aim laser at rec tangular point 5 6 Aim laser at lower point 8 294 m 7 i The result is shown in the main line and the measured distance above Pressing the measuring key for 2 sec in the function activates automatically Minimum or Ma...

Page 8: ...ance Current measured value 2 332 m 3 Min Distance i Min max measurement is also availa ble for Py thagoras calculations Maximum Tracking 1 6x 4 684 m 4 242 m Max Distance Current measured value 2 4 684 m Max Distance 3 i Min max measurement is also availa ble for Py thagoras calculations ...

Page 9: ...ring Tolerance 2 0 mm 0 08 in Maximum Measuring Tolerance 3 0 mm 0 12 in Typical Range 50 m 164 ft Range at unfavourable condition 40 m 132 ft Smallest unit displayed 1 mm 1 16 in Ø laser point at distances 6 30 mm 10 50 m General Laser class 2 Laser type 635 nm 1 mW Autom laser switch off after 90 s Autom power switch off after 180 s Battery durability 2 x AAA up to 3000 measure ments Dimension H...

Page 10: ...eiler USA Canada STABILA Inc 332 Industrial Drive South Elgin IL 60177 1 800 869 7460 The company above is responsible for supplying the product including the User Manual in a completely safe condition The company above is not responsible for third party accessories Responsibilities of the person in charge of the instrument To understand the safety instructions on the product and the instructions ...

Page 11: ...ect to abnormal use and before during and after important measurements CAUTION Never attempt to repair the product your self In case of damage contact a local dealer WARNING Changes or modifications not expressly approved could void the user s authority to operate the equipment Limits of use Refer to section Technical data The device is designed for use in areas permanently habitable by humans Do ...

Page 12: ...ncrease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Laser classification The device produces visible laser beams which are emitted from the instrument It is a Class 2 laser product in accordance with IEC60825 1 2007 Radiati...

Page 13: ...Stabila LD 320 13 EN EC Declaration of Conformity ...

Reviews: