8
en
Deactivated tilt function
If the tilt function is deactivated (white LED flashing), no
warning is given of any change in the setting/alignment in
the event of interference. In automatic operation, however,
the unit re-levels itself automatically.
7. Tilt function
The tilt function warns if any interference to the laser has
occurred that may cause misalignment. This ensures that
such interference does not go unnoticed.
The white LED (5) lights up steadily when the tilt function is
active. If any event occurs that could result in the laser unit
being deflected from its exact alignment and setting, the
beam ceases to rotate and the blue (8) and green (9) LEDs
flash. If this occurs, check the laser unit and set it up once
again if necessary.
You must press button (3) to confirm the tilt function.
Only after this can you proceed further.
The tilt function can be switched on or off in any mode
(touch button (3) briefly).
When the laser unit is switched on (button 3), tilt mode is
always initially activated.