Description
This Pedestal Sump Pump is designed for home sumps. Unit
is equipped with a 3-prong grounding-type power cord.
Sleeve bearings on motor shaft never need lubrication.
Automatic reset thermal protection.
Specifications
Power supply required......................................115V, 60 HZ.
Horsepower .......................................................................1/3
Motor duty ...........................................................Intermittent
Liquid Temp. Range ..........................32°F to 70°F(0°-21°C)
Circuit Requirement GFCI Class A .........................15 Amps
Motor full load (maximum) ....................................5.8 Amps
Discharge (ST33APP)..........................................1-1/4" NPT
Discharge (ST33APC) .........................................1-1/2" NPT
Performance
GPH (LPH) AT TOTAL FEET (M)
5 Ft. (1.52)
10 Ft. (3.05)
15 Ft. (4.57)
20 Ft. (6.09)
3000 (11 355L)
2460 (9 312L)
1620 (6 131L)
0 (0L)
General Safety Information
Electrically powered sump pumps normally give many years
of trouble-free service when correctly installed, maintained,
and used. However, unusual circumstances (interruption of
power to the pump, dirt/debris in the sump, flooding that
exceeds the pump’s capacity, electrical or mechanical fail-
ure in the pump, etc.) may prevent your pump from func-
tioning normally. To prevent possible water damage due to
flooding, consult your dealer about installing a secondary
sump pump, a DC backup sump pump, and/or a high water
alarm. See the “Troubleshooting Chart” in this manual for
information about common sump pump problems and reme-
dies. For more information, see your dealer or call customer
service at 1-800-323-0620.
1. Know the pump application, limitations, and potential
hazards. Pump water only with this pump.
Do not use in explosive atmos-
pheres. Motor is not explosion proof. Failure to
follow this warning can result in personal injury
and/or property damage.
2. Disconnect power before servicing.
3. Release all pressure within system before servicing any
component.
4. Drain all water from system before servicing.
5. Secure discharge line before starting pump. An unse-
cured discharge line will whip, possibly causing person-
al injury and/or property damage.
6. Check hoses for weak or worn condition before each
use, making certain all connections are secure.
7. Inspect sump, pump and system components monthly.
Keep free of debris and foreign objects. Perform routine
maintenance as required.
Fire Hazard - Do not store or rest
objects on or near motor or switch linkage.
Keep all flammable objects or liquids away from
motor.
8. Provide means of pressure relief for pumps whose dis-
charge line can be shut-off or obstructed.