background image

ALL NICHES:

7. Bonding:

A. If rigid non-metallic conduit is used, run a #8 solid

or stranded copper wire inside the conduit from the
bonding lug inside the niche to the junction box.
Tighten the bonding lug to 25 in-lbs. of torque.
Completely encapsulate the bonding lug inside the
niche with an approved encapsulating material as
required by the NEC and CEC.

B. If red brass conduit is used, connect a #8 solid cop-

per wire from the bonding lug on the back of the
niche to both the steel in the pool structure and to
the red brass conduit. Tighten the bonding lug to 25
in-lbs. of torque. Use an approved direct burial cold
water clamp to connect the wire to the conduit.

8. Lay vinyl in place over the niche.

9. Gasket installation: Place gasket and trim ring over the

vinyl liner and fasten them with the ten #10-24 x 1-1⁄2"
stainless steel flat head screws provided. Stainless steel
trim ring requires a gasket (Key No.10). ABS plastic trim
ring requires a gasket (Key No. 9).

Installation In Gunite Pool

(Refer to Figure 4 For Model Numbers, 05163-2352
through 2357, and 05163-2394).

1. Wire the niche to the re-bar in the desired location

(be sure that the topmost part of the lens will be
more than 18" below the water level).

Make sure that

the odd spaced holes are at the top and bottom and
that the niche is aligned so that the alignment notch
for the lamp housing is at the bottom of the niche
(threaded hole at the top - Figure 4).

2. Connect conduit to the back of the niche. If 1" or 3/4"

rigid non-metallic conduit is used, then an adapter
bushing will be required. If red brass conduit is used,
then a threaded bushing will be required.

3. Bonding:

A. If rigid non-metallic conduit is used, run a #8 solid

or stranded copper wire inside the conduit from the
bonding lug inside the niche to the junction box.
Tighten the bonding lug to 25 in-lbs. of torque.
Completely encapsulate the bonding lug inside the
niche with an approved encapsulating material as
required by the NEC.

B. If 

red brass conduit

is used, connect a #8 solid cop-

per wire from the bonding lug on the back of the
niche to both the steel in the pool structure and to
the red brass conduit. Tighten the bonding lug to 25
in-lbs. of torque. Use an approved direct burial cold
water clamp to connect the water to the conduit.

4

Liner gasket p.n. 05161-0006 if
the trim ring is ABS plastic. If
the niche is mounted to the
outside of the pool wall, use
gasket p.n. 05101-0008
between niche and wall.

Trim ring screws 
Stainless #10-24X1-1/2" 
flat head counter sunk 
phillips

Fixture locator notch

#10-24X7/8" pan head stainless screws (2). 

Liner gasket p.n. 05101-0008

Vinyl pool liner

Plug unused entry

Pool wall panel

Fixture mounting nut

1" hubs for rigid 
non-metallic conduit 
(require bushings to
adapt to other sizes 
or types of conduit)

Trim ring (stainless
contains an integral
gasket, while plastic
does not)

#10-24 Stainless Steel Nuts

Figure 2: Vinyl Liner Niche Installation

Channel gasket p.n. 05161-0004.
The thick side faces the water.

Liner gasket p.n. 05161-0006 if
the trim ring is ABS plastic. If
the niche is mounted to the
outside of the pool wall, use
gasket p.n. 05101-0008
between niche and wall.

Trim ring screws 
Stainless #10-24X1
1/2" flat head counter
sunk phillips

Fixture locator notch

#10-24X7/8" pan head stainless screws (2). Use
the two #10 stainless flat washers if the niche
is to be mounted in a Fort Wayne Pool wall panel. 

Liner gasket p.n. 05101-0008

Vinyl pool liner

Plug unused entry

Pool wall panel

Fixture mounting nut

1" hubs for rigid non-metallic
conduit (require bushings to
adapt to other sizes or types
of conduit)

Trim ring (stainless
contains an integral
gasket, while plastic
does not)

Figure 3: Vinyl Liner Niche Installation with American
Standard Pre-punched steel panels

Wire ties hold niche to
re-bar via tabs located
about the periphery of
the niche in four places

3259 0598 WG

Plug the unused
conduit entry

Bond the niche to the re-bar 
with an approved clamp;
use #8 solid copper wire 

If non metallic conduit is used then
pull #8 solid or standard copper wire
through the conduit. Completely cover
the bonding lug with encapsulating
material as required by National
Electrical Code.

Self tapping screws

Bring the plaster
surface flush with the 
edge of the niche

NOTE:

 The PVC niche internal bonding

system can be rotated as necessary.
Do this by loosening the two self
tapping screws and the jam nut on
the inside of the niche in the back.
Rotate the bonding system until the
locator notch is at the bottom of the
niche and the fixture mounting nut
is at the top. Replace the two self
tapping screws in the nearest bosses.
Retighten the nut to 20 ft./lb.

Figure 4: Gunite Pool Niche Installation

Summary of Contents for S477

Page 1: ...van WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga Ont Murrieta CA 2005 Sta Rite Industries Printed in U S A S477 Rev 1 25 05 This manual should be furnished to the end user of this niche its use will reduce service calls and chance of injury and will lengthen niche life ...

Page 2: ...t be installed in accordance with Article 680 of the National Electrical Code NEC in the United States or Section 68 of the Canadian Electrical Code CEC as applicable and all local code requirements Install an approved Ground Fault Circuit Interrupter GFCI in the electrical circuit for this light Burn hazard Never operate this light fix ture for more than 10 seconds unless it is completely submerg...

Page 3: ...k through holes in the niche flange Key No 1 Figure 5 Mark the location of these holes on the pool wall and then drill them with a 7 32 bit Fasten the niche in place with four 10 24 x 1 flat head screws Key No 4 and nuts provided Key No 3 Do not overtighten Please go to step 7 Bonding For American Standard pre punched steel panels only If you are using American Standard pre punched steel pan els t...

Page 4: ... to connect the water to the conduit 4 Liner gasket p n 05161 0006 if the trim ring is ABS plastic If the niche is mounted to the outside of the pool wall use gasket p n 05101 0008 between niche and wall Trim ring screws Stainless 10 24X1 1 2 flat head counter sunk phillips Fixture locator notch 10 24X7 8 pan head stainless screws 2 Liner gasket p n 05101 0008 Vinyl pool liner Plug unused entry Po...

Page 5: ... 1 05161 0002 10 10 24 x 1 1 2 Stainless Steel Flat Head Screw 10 37057 0615 REPAIR PARTS LIST LARGE STAINLESS STEEL LIGHT NICHES VINYL SS Key GUNITE TRIM RING No Part Description Qty 05163 2394 05163 2395 1 Niche 1 2 Hex Nut 10 24 Stainless Steel 4 35407 0031 3 10 24 x 1 Stainless Steel Pan Head Screw 4 37057 0612 4 Washer 10 Flat Stainless Steel 2 38907 0020 5 Liner Gasket 1 05101 0008 6 10 24 x...

Page 6: ...6 ...

Page 7: ...7 ...

Page 8: ...ulbs accessories and fittings manufactured by Sta Rite are warranted to be free of defects in material and or workmanship for one 1 year from the original date of installation The foregoing warranties relate to the original consumer purchas er Purchaser only Sta Rite Industries shall have the option to repair or replace the defective product at its sole discretion Purchasers must pay all labor and...

Reviews: