STA-RITE S44018T Owner'S Manual Download Page 4

Electrical / Operation / Service

4

ELECTRICAL

Hazardous voltage. Can shock, burn, or cause death.

When installing,

operating, or servicing this pump, follow safety instructions listed below.

Step 1. DO NOT splice the electrical power cord.

Step 2. DO NOT allow electrical cord plug to be submerged.

Step 3. DO NOT use extension cords. They are a fire hazard and can reduce voltage

sufficiently to prevent pumping and/or damage motor.

Step 4. DO NOT handle or service pump while it is connected to power supply.

Step 5. DO NOT remove grounding prong from plug or modify plug.To protect

against electrical shock, the power cord is a three-wire conductor and
includes a 3-prong grounded plug. Plug pump into a 3-wire, grounded,
grounding-type receptacle. Connect pump according to electrical codes that
apply.

For automatic operation, plug or wire pump into an automatic float switch or pump
controller. Pump will run continuously when plugged directly into an electrical out-
let. Connect or wire pump to an individual branch circuit with no other outlets or
equipment in the circuit. Size fuses or circuit breakers according to chart below.

Risk of electrical shock and fire. Be sure that power supply informa-

tion (Voltage/ Hertz/Phase) on pump motor nameplate matches incoming power
supply exactly. Install pump according to all electrical codes that apply.

FPSE 

Individual Branch Circuit 

Dual Element Time 

Model

H.P.

Voltage

Required (Amps)

Delay Fuse Amps

S44018T

1/2

115

15

10

OPERATION AND INSTALLATION

NOTICE:

Do not allow pump to run in a dry sump. It will void the warranty and may

damage the pump.

An automatic overload protector in the motor will protect motor from burning out
due to overheating/overloading. When motor cools down, overload protector will
automatically reset and start motor.

If overload trips frequently, check for cause. It could be a stuck impeller, wrong/low
voltage, or electrical failure in motor. If an electrical failure in the motor is suspected,
have it serviced by a competent repairman.

Pump is permanently lubricated. No oiling or greasing is required.

GENERAL

Hazardous voltage. Can shock, burn, or cause death.

Before removing

pump from basin for service, always disconnect electrical power to pump and con-
trol switch.

Risk of electrical shock. Can burn or kill.

Do not lift pump by ower

cord. See “Cord Lift Warning” on Page 5.

Submerge pump in a disinfectant solution (chlorox or chlorine) for at least one hour
before disassembling pump.

The pump motor contains a special lubricating oil which should be kept clean and
free of water at all times.

Summary of Contents for S44018T

Page 1: ...MANUAL Sewage Ejector Pump 2005 S587 Rev 6 2 05 Model S44018T Installation Operation Parts For further operating installation or maintenance assistance Call 1 888 782 7483 293 Wright Street Delavan W...

Page 2: ...t they will be free from defects in material and workman ship for the Warranty Period from the date of original installation or manufacture as noted Product Warranty Period Water Systems Products jet...

Page 3: ...be capable of handling semi solids of at least 2 5 1 cm diameter The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid To meet minimum flow requirements 2 feet...

Page 4: ...upply informa tion Voltage Hertz Phase on pump motor nameplate matches incoming power supply exactly Install pump according to all electrical codes that apply FPSE Individual Branch Circuit Dual Eleme...

Page 5: ...n reconnect to power source Check for cause of overheating overloading 1 Be sure all valves in discharge valve are fully open 2 Clean out discharge pipe and check valve 3 Check for blockage in pump in...

Page 6: ...Part S440118T No Description Qty 115 Volt 1 Lower Volute 1 PW1 11P 2 Impeller 1 PW5 15P 3 Upper Volute 1 PW1 10P 4 Power Cord 1 PS117 53 TSE 5 Automatic Float Switch 1 PW217 179B 4 3 2 1 5 IF MOTOR F...

Page 7: ...para aguas residuales 2005 S587 Rev 6 2 05 Modelo S44018T Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 888 782 7483 2...

Page 8: ...Al hacer una reparaci n reemplace este aceite por aceite nuevo ADVERTENCIA ADVERTENCIA PRECAUCI N ADVERTENCIA PELIGRO GARANTIA LIMITADA Sta Rite Industries garantiza al consumidor original de los pro...

Page 9: ...a velocidad del flujo en la tuber a de descarga debe poder mantener los s lidos en suspensi n en el l quido Para mantener el caudal m nimo necesario velocidad de 2 pies o 0 6 m por segundo en el ca o...

Page 10: ...n mero de fases inscrita en la chapa del motor de la bomba corresponde exactamente a la de la corriente el ctrica utilizada Instale la bomba en conformidad con todos los c digos de electricidad que c...

Page 11: ...corriente el ctrica Investigue la causa del sobrecalentamiento o sobrecarga 1 Aseg rese de que todas las v lvulas en la tuber a de descarga est n totalmente abiertas 2 Limpie el ca o de descarga y ve...

Page 12: ...zas Cantidad 115 Volt 1 Voluta inferior 1 PW1 11P 2 Rodete 1 PW5 15P 3 Voluta superior 1 PW1 10P 4 Cable de alimentaci n 1 PS117 53 TSE 5 Interruptor autom tico de flotador 1 PW217 179B 4 3 2 1 5 LIST...