D. If the ring was already locked, remove it and the fil-

ter lid assembly. Inspect and clean the O-ring and all
sealing surfaces. Relubricate the O-ring, if necessary.

NOTICE:

Lubricate the O-ring sealing area inside the

upper tank lip with silicone grease, as other lubricants
may cause the ring to swell. DO NOT lubricate the Posi-
Ring™ or the threads on tank shell as this may collect
grit and make removal difficult.
After the filter is operating, record the filter pressure
gauge reading in the owner's manual for future use.

FILTER DISASSEMBLY/
ASSEMBLY PROCEDURE

Before disassembling filter:
1. STOP PUMP.
2. OPEN air release valve and drain fitting.
3. WAIT until all pressure is released and water drained

from filter tank and system before loosening Posi-Ring™.

Disassembly:

1. Stop the pump.
2. Open air release valve on top of filter tank to release

all pressure from inside of tank.

3. Remove the drain cap and drain all water from the tank.
4. Remove filter lid assembly as follows:

a. Press the safety latch (below the ring) toward the

tank to release it (see Figure 4).

b. Hold the latch in the release position and rotate the

ring COUNTERCLOCKWISE to remove it. If the ring
is difficult to turn, tap it gently with a rubber mallet
to overcome initial resistance.

5. Inspect the O-ring for cuts, cracking, deformation or

signs of wear; replace if necessary. 

NOTICE:

Do not remove the O-ring unless you need

to replace it. To remove it, hook it out of its groove with
a stiff curved piece of wire inserted through the small
access slot in the bottom of the tank lid assembly.

SAFETY LATCH

The purpose of the safety latch is to hold the Posi-Ring™
in the locked position. If the latch is damaged, replace it
as follows:
1. Press up on the small catch on the bottom of the safety

latch and press or tap the latch out of the slot in the tank.

2. Slide the new latch into position until it latches in

place.

NOTICE: 

DO NOT operate the filter if the safety latch

is damaged or will not hold the Posi-Ring™ in the
locked position.

Assembly:

1. Inspect and clean the tank, ring threads and O-ring

groove. Replace damaged parts as necessary.

2. Install the filter cartridge in the tank. Push down firmly

to seal it.

NOTICE:

Lubricate the O-ring sealing area inside the

upper tank lip with silicone base grease, as other lu-
bricants may cause the ring to swell. DO NOT lubri-
cate the Posi-Ring™ or the threads on the tank shell
as this may collect grit and make removal difficult.

3. Install the O-ring in the tank lid assembly O-ring

groove. Be sure that the O-ring is clean and not
twisted.

NOTICE:

Do not remove the O-ring unless you need

to replace it.

4. Place the Posi-Ring™ squarely over the tank shell

threads and rotate it CLOCKWISE until it is securely
latched.

5. Follow instructions in the “Initial Startup” section of

this manual.

PU

SH

PU

SH

Figure 4 – Depress safety latch to unscrew the 
Posi-Ring™.

Summary of Contents for Posi Clear PXC125

Page 1: ...WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga ON 2005 Sta Rite Industries S620 Rev 12 5 05 This manual should be furnished to the end user...

Page 2: ...151 60 227 80 303 100 379 120 454 140 530 160 606 Flow in GPM LPM Pressure Drop in PSI kPa PXC75 Max Flow PXC150 Max Flow PXC95 Max Flow PXC125 Max Flow Pressure Drop Curve for all PXC Models Table 2...

Page 3: ...ould nor mally be cleaned when the pressure gauge reading in creases 10 PSI over the start up pressure In some pools accessories such as fountains or pool cleaners may be noticeably affected by the no...

Page 4: ...dure Do not operate filter at more than 50 PSI 345 kPa 1 Securely lock the Posi Ring in place by rotating it CLOCKWISE until it clicks past the safety latch see Figure 3 Stop turning as soon as the ri...

Page 5: ...e if necessary NOTICE Do not remove the O ring unless you need to replace it To remove it hook it out of its groove with a stiff curved piece of wire inserted through the small access slot in the bott...

Page 6: ...lter sol vents may damage plastic components in the system NOTICE Open the air release valve and bleed all air from the filter each time the pump is stopped and restarted Weekly Inspection 1 Remove de...

Page 7: ...essional C Excessive air in filter Vent air from tank and check for pump suction pipe leaks Clean air bleed tube in cartridge assembly D Pool water contains iron Consult your pool professional E Heavy...

Page 8: ...0001S 25230 0001S 5 Water Diverter 1 25230 0006 25230 0006 25230 0006 25230 0006 6 Drain Cap with Gasket 1 32185 7074 32185 7074 32185 7074 32185 7074 7 Safety Latch 1 25200 0007 25200 0007 25200 000...

Page 9: ...s ac cessories and fittings manufactured by Sta Rite are warranted to be free of defects in material and or workmanship for one 1 year from the original date of installation The foregoing warranties r...

Page 10: ...10...

Page 11: ...WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga ON 2005 Sta Rite Industries S620 R v 5 12 05 Cette Notice doit tre remise l utilisateur de ce...

Page 12: ...50 D bit max PXC95 D bit max PXC125 D bit max Courbe des chutes de pression de tous les mod les PXC Tableau 2 Sp cifications des filtres N des mod les PXC75 PXC95 PXC125 PXC150 Surface de filtration e...

Page 13: ...ure 10 lb po2 par rapport la pression de mise en service Dans certaines piscines des accessoires comme des fontaines ou des nettoyeurs automatiques de piscine peuvent tre consid rablement affect s par...

Page 14: ...u de la municipalit MISE EN SERVICE INITIALE S assurer que la pompe est ARR T E avant de proc der la mise en service Ne jamais faire fonctionner ce filtre par des pressions sup rieures 50 lb po2 345 k...

Page 15: ...ser le joint torique tant que l on n est pas pr t le remplacer Pour le d poser le sortir de sa gorge avec un fil de fer rigide courb son extr mit que l on introduira dans la petite fente d acc s qui s...

Page 16: ...ants en plas tique du syst me NOTA Ouvrir le purgeur d air et chasser tout l air du filtre chaque fois que l on arr te la pompe puis qu on la remet en marche Inspection hebdomadaire 1 Enlever tous les...

Page 17: ...ter un pro fessionnel en piscines C Quantit d air excessive dans le filtre Nettoyer le tube de purge d air de la cartouche filtrante D L eau de la piscine contient du fer Consulter un profes sionnel e...

Page 18: ...0001S 5 D rivation de l eau 1 25230 0006 25230 0006 25230 0006 25230 0006 6 Bouchon de vidage et joint 1 32185 7074 32185 7074 32185 7074 32185 7074 7 Verrou de s curit 1 25200 0007 25200 0007 25200 0...

Page 19: ...ires les appareils d clairage im merg s l exception des ampoules et les raccords fabriqu s par Sta Rite sont garantis contre tout d faut de mat riel et ou de fabrication pendant un 1 an compter de la...

Page 20: ...20...

Page 21: ...Internacional 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Mississauga ON 2005 Sta Rite Industries S620 Rev 12 5 05 Este manual debe entregarse al usuario final de este filtr...

Page 22: ...adrada psi kPa PXC75 caudal m x PXC95 caudal m x PXC125 caudal m x PXC150 caudal m x SP Curva de ca da de presi n para todos los modelos PXC Tabla 2 Especificaciones del filtro Modelo No PXC75 PXC95 P...

Page 23: ...e limpiar generalmente cuando la lectura del man metro aumenta 10 lb pulg cuadrada psi por encima de presi n de inicio En ciertas piscinas es posible que a medida que el filtro se en sucia el impacto...

Page 24: ...dimiento de arranque veri fique que la bomba est apagada Nunca opere el filtro a m s de 50 libras pulgada2 345 kPa 1 Trabe el Posi RingTM firmemente en posici n haci ndolo girar HACIA LA DERECHA hasta...

Page 25: ...e reemplace si fuese necesario AVISO No saque el aro t rico a menos que sea necesario reemplazarlo Para sacarlo eng nchelo y s quelo de su canaleta con un trozo curvo y r gido de alambre introducido e...

Page 26: ...elva a encender la bomba abra la v lvula de descarga de aire y purgue todo el aire del filtro Inspecci n semanal 1 Elimine la suciedad de la cesta de la espumadera de la piscina 2 Detenga la bomba abr...

Page 27: ...ntile el aire del tanque y verifique que la tuber a de aspiraci n de la bomba no tenga fugas Limpie el tubo de purga de aire en la unidad del cartucho D El agua de la piscina contiene hierro consulte...

Page 28: ...ector de agua 1 25230 0006 25230 0006 25230 0006 25230 0006 6 Tapa de desag e con empaquetadura 1 32185 7074 32185 7074 32185 7074 32185 7074 7 Pasador de seguridad 1 25200 0007 25200 0007 25200 0007...

Page 29: ...ndo los focos y los accesorios fabricados por Sta Rite est n cu biertos por una garant a contra defectos en material y o mano de obra por un 1 a o desde la fecha inicial de instalaci n Las garant as q...

Page 30: ...30...

Page 31: ...31...

Page 32: ...32...

Reviews: