STA-RITE HN series Owner'S Manual Download Page 6

Discharge Pipe and Pressure Tank Connections

6

PRE-CHARGE TANK CONNECTION (Figure 4)

Step 1. Install two tees in the pump discharge port (see Figure 4). The pipe

size must be at least as large as the discharge port.

Step 2. Run a pipe or reinforced hose from one arm of the first tee to the

port on the pre-charged tank.

Step 3. Connect the other end of the discharge tee to your plumbing sys-

tem. 

Step 4. Check the pre-charge of air in the tank with an ordinary tire gauge.

The pre-charge should be 2 PSI less than the cut-in setting of the
pump’s pressure switch. The pre-charge is measured 

when there is

no water pressure in the tank. Your new pump has a 30/50 PSI
switch, so adjust the tank pre-charge pressure to 28 PSI.

Congratulations! You have just completed the tank connection for
your jet pump. 

Please go to Pages 7 and 8 for electrical hookup.

STANDARD TANK CONNECTION (Figure 5)

Step 1. Install one tee in the pump discharge port (see Figure 5). 

Step 2. Run a pipe from the pump discharge port to the inlet port of your

tank. The pipe size must be at least as large as the discharge port.

Step 3. Remove the 1/8” NPT pipe plug from the pump Air Volume Control

(AVC) port (see Figure 5). Run tubing from the pump’s AVC port
(see Figure 5) to the port on the AVC mounted on the tank. See
instructions provided with tank and AVC for details. AVC port loca-
tion will vary, depending on your pump model (see exploded view,
Page 11).

Congratulations! You have just completed the tank connection for
your jet pump. 

Please go to Pages 7 and 8 for electrical hookup.

From Well

Pressure
Switch

To Household
Water System

Pump Priming
Tee and Plug

Check 
Valve

2349 0396

To Household
Water System

From
Well

Air Volume
Control

Air Volume
Control Tube

Pump 
Priming Tee
and Plug

Pressure
Switch

2350 0396

Check
Valve

Figure 4: Pre-charged Tank Connections

Figure 5: Standard Tank Connections

Sealing Pipe Joints

Use only Teflon tape or Teflon based joint compounds for 
making all threaded connections to the pump itself. Do not use
pipe joint compounds on plastic pumps: 
they can react with
the plastic in pump components. Make sure that all pipe joints
in the suction pipe are air tight as well as water tight. 

If the 

suction pipe can suck air, the pump will not be able to pull
water from the well.

Summary of Contents for HN series

Page 1: ...mps Tank Systems 2001 Sta Rite Industries Inc PRINTED IN U S A S410 Rev 6 13 01 293 Wright Street Delavan WI 53115 HN Series Installation Operation Parts For further operating installation or maintena...

Page 2: ...ouch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump...

Page 3: ...5 13 3 9 5 3 4 HP 40 20 8 18 7 15 8 13 2 9 3 67 50 13 5 11 6 10 1 7 4 2 4 HNE L 30 28 5 25 0 21 4 17 4 12 6 1 HP 40 28 3 24 4 21 0 17 2 12 3 67 50 21 5 18 3 10 9 3 1 1 6 Performance Chart Performance...

Page 4: ...s large as the suction port on the pump include a check valve if your pump is not equipped with one see Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the...

Page 5: ...pipe The suction pipe should be at least as large as the suction port on the pump Step 2 Assemble a foot valve and suction pipe see Figure 3 Make sure that the foot valve works freely Use teflon tape...

Page 6: ...ize must be at least as large as the discharge port Step 3 Remove the 1 8 NPT pipe plug from the pump Air Volume Control AVC port see Figure 5 Run tubing from the pump s AVC port see Figure 5 to the p...

Page 7: ...ngle voltage motor Connect power supply as shown for your type of switch and your supply voltage Pull plug straight out from terminal board 1 1 2 2 Plug in again with arrow on plug pointing to 115 Vol...

Page 8: ...completed the wiring for your pump Please go to Page 9 for startup preparations DISTANCE IN FEET METERS FROM MOTOR TO SUPPLY 0 100 101 200 201 300 301 400 401 500 Max Load Branch Fuse 0 30 31 61 62 91...

Page 9: ...to get all the trapped air out of the piping A pump lifting water 25 may take as long as 15 minutes to prime Step 4 After the pump has built up pressure in the system and shut off check the pressure...

Page 10: ...are Raise foot valve and or strainer above bottom of water source buried in sand or mud Clean foot valve and strainer Water level is too low for shallow well A deep well jet package may be needed ove...

Page 11: ...mp Body Assembly 1 N176 43B N176 43B N176 44 N176 44 N176 44A N176 44A 11A Venturi 1 N32P 75 N32P 75 N32P 64 N32P 64 N32P 65 N32P 65 11B Nozzle 1 N34P 21 47 N34P 21 47 J34P 44 54 J34P 44 54 J34P 44 54...

Page 12: ...ick trip overload relays of recom mended size are not used our warranty is void Buyer s only remedy and Sta Rite Industries Inc s only duty is to repair or replace defective products at Sta Rite Indus...